Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT03391544
Other study ID # 4-2017-0243
Secondary ID
Status Recruiting
Phase N/A
First received December 21, 2017
Last updated January 4, 2018
Start date April 28, 2017
Est. completion date April 2018

Study information

Verified date December 2017
Source Yonsei University
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The recently introduced toric V4c toric ICL (STAAR Surgical Company, Monrovia, CA, USA) has been designed with a 360-µm central hole to allow aqueous humor to flow without the need for an iridotomy. As far as the investigators certain, there have been not well-established prospective studies on the role of the V4c toric ICL for myopic astigmatism correction. Therefore, the present study aimed to investigate the clinical outcomes and rotational stability and to analyze factors that influence the rotational stability in V4c toric ICL implanted eyes prospectively.


Recruitment information / eligibility

Status Recruiting
Enrollment 75
Est. completion date April 2018
Est. primary completion date April 2018
Accepts healthy volunteers No
Gender All
Age group 19 Years to 45 Years
Eligibility Inclusion Criteria:

- Age 19-45 years

- Presence of myopia with a manifest refraction spherical equivalent between -5.00 and -20.00 diopters (D)

- Astigmatism between -0.75 and -5.00 D

Exclusion Criteria:

- Previous ocular or intraocular surgery (other than ICL implant)

- Anterior chamber depth from the endothelium < 2.8 mm

- Corneal endothelial cell density < 2000 cells/mm2

- Evidence of acute or chronic corneal infection, corneal inflammation

- Glaucoma, amblyopia, retinal detachment, diabetic retinopathy, macular degeneration, or neuro-ophthalmic disease

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
V4c toric ICL implantation surgery
The size and power of the V4c toric ICL were determined following the manufacturer's guidelines using a modified vertex formula. Emmetropia was the target refraction following surgery in all cases. Before surgery, three centration points were marked using the slit lamp while the patient, in sitting position, fixated on the center of the slit-lamp beam, which was narrowed as much as possible.

Locations

Country Name City State
Korea, Republic of Department of Ophthalmology, Yonsei University College of Medicine Seoul

Sponsors (1)

Lead Sponsor Collaborator
Yonsei University

Country where clinical trial is conducted

Korea, Republic of, 

Outcome

Type Measure Description Time frame Safety issue
Primary Visual outcome Evaluation of logarithm of the minimum angle of resolution (logMAR) uncorrected distance visual acuity (UDVA) and CDVA, manifest refraction, autorefractor-keratometer (ARK-530A; Nidek Co., Ltd.). The change of astigmatism was analyzed by the Alpins method. 6 months after the surgery
Primary Refractive outcome Evaluation of logarithm of the minimum angle of resolution (logMAR) uncorrected distance visual acuity (UDVA) and CDVA, manifest refraction, autorefractor-keratometer (ARK-530A; Nidek Co., Ltd.). The change of astigmatism was analyzed by the Alpins method. 6 months after the surgery
Secondary Rotational stability Rotational stability of the toric ICL was measured using the OPD-Scan III (NIDEK Co. Ltd., Gamagori, Japan). The rotation was defined as the difference between the intended axis and the achieved axis at each follow-up. Assuming that the adjusted axis was identical to the intended angle, postoperative rotation was automatically measured by determining the angle between the adjusted axis and alignment axis. Each measurement was performed three times by one physician, and the average of the three measurements was used in the analysis. immediately after the surgery
Secondary Rotational stability Rotational stability of the toric ICL was measured using the OPD-Scan III (NIDEK Co. Ltd., Gamagori, Japan). The rotation was defined as the difference between the intended axis and the achieved axis at each follow-up. Assuming that the adjusted axis was identical to the intended angle, postoperative rotation was automatically measured by determining the angle between the adjusted axis and alignment axis. Each measurement was performed three times by one physician, and the average of the three measurements was used in the analysis. 3 months after the surgery
Secondary Rotational stability Rotational stability of the toric ICL was measured using the OPD-Scan III (NIDEK Co. Ltd., Gamagori, Japan). The rotation was defined as the difference between the intended axis and the achieved axis at each follow-up. Assuming that the adjusted axis was identical to the intended angle, postoperative rotation was automatically measured by determining the angle between the adjusted axis and alignment axis. Each measurement was performed three times by one physician, and the average of the three measurements was used in the analysis. 6 months after the surgery
See also
  Status Clinical Trial Phase
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT00366769 - Evaluation of Outcomes Following LASIK Surgery Using CustomVue N/A
Completed NCT00366574 - Comparison of a Laser Keratome to a Mechanical Microkeratome N/A
Completed NCT02939001 - Evaluating the Effect of Laser Vision Surgery, Phakic Intraocular Lens Implantation, Cataract Surgery, and Pupil Dilation on the Iris Recognition Scanner Function of Smartphone N/A
Completed NCT02103309 - Comparative Evaluation of Contact Lens Centering of DAILIES® AquaComfort Plus® Versus 1-DAY ACUVUE® MOIST® in Japan N/A
Enrolling by invitation NCT05684237 - Using the VisuMax Femtosecond Laser System to Perform SMILE Optimized for Presbyopia by Modulation of Postoperative Spherical Aberration N/A
Recruiting NCT05229133 - Efficacy and Safety of CLEAR in Myopia and Astigmatism in Chinese Population N/A
Recruiting NCT06062004 - Evaluation of Different Lenticule Diameters in Myopic Astigmatism Correction With SMILE Procedures N/A
Completed NCT00366743 - Evaluation of Visual Outcomes After Myopic LASIK N/A
Recruiting NCT06371079 - Safety and Suitability of ICL for Correction of Refractive Errors Without the Use of Dispersive OVDs
Recruiting NCT06229301 - A Study of Artificial Intelligence Assisted Small Incision Lenticule Extraction (SMILE) for Surgical Design and Influencing Factors
Active, not recruiting NCT01404884 - SUPRACOR for Myopia and Myopic Astigmatism Phase 3
Completed NCT04111757 - A Study With Technolas® TENEO 317 Model 2 Excimer Laser to Treat Participants With Myopia or Myopic Astigmatism N/A
Completed NCT03913338 - Laser In-situ Keratomileusis With Crosslinking Compared to Conventional LASIK in Patients With High Myopia N/A
Active, not recruiting NCT04516772 - STAAR Visian Toric ICL Post-Approval Study N/A
Completed NCT04283149 - Multicenter Clinical Trial of a Phakic Implantable Collamer® Lens (ICL) N/A
Recruiting NCT05670626 - Correlation Between Preoperative Refraction and Anterior Segment Parameters With ICL Vault N/A
Completed NCT03947944 - Clinical Outcomes of Small-incision Lenticule Extraction (SMILE) Using Vector Planning Method. N/A
Completed NCT01097525 - Optical Quality, Threshold Target Identification, and Military Target Task Performance After Advanced Keratorefractive Surgery N/A