Myopia Clinical Trial
Official title:
Effect of Light Emitting Diodes With a Continuous Spectrum of 430-780nm Used in the Classroom on Myopia Prevention Among School-Aged Children: A Cluster Randomized Controlled Trial
The purpose of this clinical trial is to evaluate the effect of light-emitting diodes (LEDs) with a continuous spectrum of 430-780 nm for lighting in the classroom on myopia prevention among children in Grades 2 and 3.
Myopia is a common condition that primarily arises in childhood and remains the most important cause of vision loss for children. Irreversible vision-threatening ocular complications such as posterior staphyloma, myopic maculopathy, and glaucoma may occur with a dramatically high risk once myopia progresses to high myopia. Considering the striking rapid increases in the prevalence of myopia and the premature age of myopia onset, myopia prevention is of extreme urgency and presents several challenges. It has been proven with solid evidence that outdoor times has effects on myopia prevention, which may be attributed to outdoor light exposure. However, it is difficult to meet the required outdoor times (i.e., at least 2 hours/day) for school-aged children under such educational pressure, especially in China. The differences between the light outdoors and indoors in terms of the light spectrum provide some insights into research to find the alternative. The growth rate of the vitreous cavity in juvenile and adult tree shrews grown under red light with a wavelength of 628±10 nm was significantly slower than those grown under the normal fluorescent lighting group, and red light could induce a hyperopic shift in juvenile tree shrews, thus slowing down the development of myopia. Another experiment has also shown that the use of full-spectrum LED covering a continuous spectrum of 400-775 nm accelerated the recovery from form-deprivation myopia in chickens, and it is hypothesized that full-spectrum lighting may affect the choroid-scleral remodeling pathway, which is thought to be associated with myopia control. The purpose of this study is to evaluate the effects of LEDs covering a continuous spectrum of 430-780 nm for lighting in the classroom (intervention arm) among students in Grades 2 and 3 compared with regular LEDs with a spectrum of 430-630 nm (control arm). Cluster randomization by class was chosen, and all classes in the same school and grade were equally and randomly assigned to the intervention or control arm, with follow-ups at 1- and 2-year. Vision acuity, ocular biometry, cycloplegic refraction, slit-lamp examinations, optical coherence tomography, optical coherence tomography angiography, and questionnaires will be performed at baseline and during the follow-up. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04923841 -
Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine
|
N/A | |
Active, not recruiting |
NCT04080128 -
Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control
|
N/A | |
Active, not recruiting |
NCT05275959 -
Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI)
|
N/A | |
Completed |
NCT04604405 -
Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation
|
N/A | |
Recruiting |
NCT05594719 -
The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow
|
N/A | |
Completed |
NCT05594732 -
The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow
|
N/A | |
Completed |
NCT04492397 -
Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI)
|
N/A | |
Completed |
NCT04536571 -
Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses
|
N/A | |
Completed |
NCT06046209 -
Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens
|
N/A | |
Recruiting |
NCT06344572 -
Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia
|
Phase 3 | |
Recruiting |
NCT05611294 -
Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction
|
N/A | |
Completed |
NCT05656885 -
Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses
|
N/A | |
Active, not recruiting |
NCT05534022 -
Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression.
|
N/A | |
Completed |
NCT03934788 -
the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens
|
N/A | |
Completed |
NCT03701516 -
Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2
|
N/A | |
Completed |
NCT05538754 -
Post-Market Evaluation of the EVO ICL
|
N/A | |
Completed |
NCT03139201 -
Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens
|
N/A | |
Completed |
NCT02555722 -
Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear
|
N/A | |
Not yet recruiting |
NCT06009458 -
Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
|
N/A | |
Recruiting |
NCT05548478 -
Corneal Endothelial Cell Injury Induced by Mitomycin-C
|
N/A |