Myopia Clinical Trial
NCT number | NCT01977807 |
Other study ID # | 1303 |
Secondary ID | |
Status | Recruiting |
Phase | Phase 4 |
First received | October 31, 2013 |
Last updated | May 19, 2015 |
Start date | August 2014 |
This clinical study has been planned to evaluate the safety and effectiveness of common treatment algorithms using 500 Hz laser repetition rate.
Status | Recruiting |
Enrollment | 100 |
Est. completion date | |
Est. primary completion date | December 2016 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years to 85 Years |
Eligibility |
General Inclusion Criteria - Subjects have to be at least 18 years of age. - Subjects have to be able to read, understand, and sign a statement of Informed Consent. - Subjects have to be willing and able to return for scheduled follow-up examinations for up to 6 and 12 months respectively after surgery. - Corneal topography should be qualified - High contrast, manifest, best spectacle-corrected distance visual acuity correctable binocular to at least 1.0 (Snellen 20/20 or 6/6) and monocular to at least 0.8 (Snellen 20/25 or 6/7.5). In case of a monocular surgery the eye which should not be treated must have a best corrected distance visual acuity of at least 0.8 (Snellen 20/25 or 6/7.5). - Mesopic pupil size measured with the Zywave II WaveFront Aberrometer must be < 7.0 mm and photopic pupil size measured with the Orbscan II/ IIz must be > 2.9 mm. Additional Inclusion Criteria for Proscan Treatments - For Proscan myopic subjects require a sphere between -0.5 D up to -10.0 D and cylinder between -0.5 D up to -4.0 D (not corneal astigmatism) and SE up to -12.0 D - For Proscan hyperopic subjects require a sphere between +0.5 D up to +4.0 D and cylinder between +0.5 D up to +4.0 D (not corneal astigmatism) and SE up to +6.0 D. Additional Inclusion Criteria for Zyoptix Treatments For Zyoptix myopic subjects require a sphere between -0.5 D up to -10.0 D and cylinder between -0.5 D up to -4.0 D (not corneal astigmatism) and SE up to -12.0 D - For Zyoptix hyperopic subjects require a sphere between +0.5 D up to +4.0 D and cylinder between +0.5 D up to +4.0 D (not corneal astigmatism) and SE up to +6.0 D. - For all treatments with the Zyoptix algorithm, the high-order-aberration must be at least 0.35µm. Additional Inclusion Criteria for Supracor Treatments - For treatments with the SUPRACOR presbyopic algorithm, subjects have to be at least 45 years old and no more than 85 years - Myopic subjects must have up to -7.0 diopters (D) of absolute spherical myopia (not spherical equivalent), with up to -4.0 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction. The spherical equivalent and must be no more than -9.0 D. - Hyperopic subjects must have up to +4 diopters (D) of absolute spherical hyperopia (not spherical equivalent), with up to +2.5 D of refractive astigmatism (NOT corneal astigmatism) by manifest subjective refraction in both eyes. The spherical equivalent must be no more than +5.25 D. - Subjects must have presbyopia as determined by an age-related need for optical aid(> +1.50 D) for reading with their best distance correction and been screened success-fully for acceptance of the SUPRACOR simulation. Exclusion Criteria - Subjects for whom the combination of their baseline corneal thickness and the planned operative parameters for the LASIK procedure would result in less than 250 microns of remaining posterior corneal thickness below the flap postoperatively. - Hyperopic eyes for which the baseline manifest subjective refraction exhibits a difference of greater than ± 0.75 D in sphere power, or a difference of greater than ± 0.50 D in cylinder power, or a difference in cylinder axis of more than 15 degrees compared to the baseline cycloplegic subjective refraction. For manifest cylinder of less than ±0.75 D, the differ-ence in cylinder axis would not be taken into consideration. - Subjects with anterior segment pathology, including dry eye syndrome and cataracts, which in the Investigator's opinion would interfere with best spectacle-corrected visual acuity or a successful treatment. - Subjects with evidence of retinal vascular disease. Subjects with any residual, recurrent, or active ocular disease, or corneal abnormality that in the Investigator's opinion would interfere with BSCVA or a successful treatment. - Subjects with signs of keratoconus or Subjects with unstable central keratometry readings with irregular mires. - Subjects who had previous intraocular or corneal surgery of any kind, including any type of Excimer laser surgery for either refractive or therapeutic purposes. - Subjects who have a history of Herpes simplex or Herpes zoster keratitis or history of glaucoma or glaucoma suspect, corneal edema, or increased IOP > 22mmHg or risk for angle closure. - Subjects immunocompromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, diabetes, autoimmune diseases and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study. - Subject taking systemic medications likely to affect wound healing such as corticosteroids or antimetabolites. - Subjects who are known to be pregnant, lactating, or who plans to become pregnant over the course of the study. - Subjects with an ocular muscle disorder including a strabismus or nystagmus, or other disorders affecting fixation. - Subjects with cognitive impairments or other vulnerable persons. |
Allocation: Non-Randomized, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment
Country | Name | City | State |
---|---|---|---|
Philippines | Asian Eye Institut | Manila |
Lead Sponsor | Collaborator |
---|---|
Technolas Perfect Vision GmbH |
Philippines,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | For Proscan and Zyoptix: - The percentage of treated eyes within +/- 0.50D of target refraction. For Supracor: - The percentage of treated eyes with a best corrected high contrast distance VA of Snellen 20/25 (6/7.5 or 0.1 logMAR) or better | Myopia: 6 months, Hyperopia 12 months | No |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04923841 -
Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine
|
N/A | |
Active, not recruiting |
NCT04080128 -
Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control
|
N/A | |
Active, not recruiting |
NCT05275959 -
Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI)
|
N/A | |
Completed |
NCT04604405 -
Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation
|
N/A | |
Recruiting |
NCT05594719 -
The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow
|
N/A | |
Completed |
NCT05594732 -
The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow
|
N/A | |
Completed |
NCT04492397 -
Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI)
|
N/A | |
Completed |
NCT04536571 -
Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses
|
N/A | |
Completed |
NCT06046209 -
Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens
|
N/A | |
Recruiting |
NCT06344572 -
Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia
|
Phase 3 | |
Recruiting |
NCT05611294 -
Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction
|
N/A | |
Completed |
NCT05656885 -
Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses
|
N/A | |
Active, not recruiting |
NCT05534022 -
Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression.
|
N/A | |
Completed |
NCT03934788 -
the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens
|
N/A | |
Completed |
NCT03701516 -
Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2
|
N/A | |
Completed |
NCT05538754 -
Post-Market Evaluation of the EVO ICL
|
N/A | |
Completed |
NCT03139201 -
Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens
|
N/A | |
Completed |
NCT02555722 -
Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear
|
N/A | |
Not yet recruiting |
NCT06009458 -
Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear
|
N/A | |
Recruiting |
NCT05548478 -
Corneal Endothelial Cell Injury Induced by Mitomycin-C
|
N/A |