Clinical Trials Logo

Clinical Trial Summary

Emtosecond lasers are used in cutting the flap in LASIK procedures (laser corrective surgery for refractive error). Their use has decreased the incidence of serious complications when compared to the use of microkeratomes(mechanical blades). The commonest femtosecond laser currently used is 'Intralase'. A newer femtosecond laser 'Visumax' (Zeiss) is now available and differs from the Intralase in that it does not interfere with the curvature of the cornea when creating the flap. The Intralase applanates the cornea flat during flap creation which causes the intraocular pressure to be higher. Both Intralase and Visumax lasers are available to patients and surgeons to use at SNEC. The aim of the investigators study is to compare the two lasers in a randomization of left and right eyes in the same patient. The investigators want to measure any difference that the lower intraocular pressure may have during the creation of the flap. This will be measured with a questionaire on patient experience during the procedure and the outcomes of vision, refraction, contrast sensitivity, wave-front analysis, tear function,corneal sensation and flap thickness measured with anterior segment OCT during the post-operative follow up period. To date no-one has compared the use of these two femtosecond lasers. Both lasers are currently used clinically for flap creation at SNEC.


Clinical Trial Description

n/a


Study Design

Observational Model: Case Control, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT01252654
Study type Observational
Source Singapore Eye Research Institute
Contact
Status Completed
Phase N/A
Start date January 2010
Completion date August 2013

See also
  Status Clinical Trial Phase
Recruiting NCT04923841 - Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine N/A
Active, not recruiting NCT04080128 - Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control N/A
Active, not recruiting NCT05275959 - Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI) N/A
Completed NCT04604405 - Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation N/A
Recruiting NCT05594719 - The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow N/A
Completed NCT05594732 - The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow N/A
Completed NCT04492397 - Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI) N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Recruiting NCT06344572 - Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia Phase 3
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Active, not recruiting NCT05534022 - Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression. N/A
Completed NCT03934788 - the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT03701516 - Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2 N/A
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT03139201 - Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT02555722 - Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear N/A
Not yet recruiting NCT06009458 - Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear N/A
Recruiting NCT05548478 - Corneal Endothelial Cell Injury Induced by Mitomycin-C N/A