Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01093625
Other study ID # CR-0916
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date January 2010
Est. completion date April 2011

Study information

Verified date May 2015
Source Johnson & Johnson Vision Care, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to evaluate the effect of an investigational silicone hydrogel soft contact lens on new contact lens wearers (neophytes) compared to a control of spectacle wearers.


Recruitment information / eligibility

Status Completed
Enrollment 157
Est. completion date April 2011
Est. primary completion date April 2011
Accepts healthy volunteers No
Gender All
Age group 15 Years to 39 Years
Eligibility Inclusion Criteria:

- Able to read, comprehend and sign an informed consent (or parental consent/subject assent, as appropriate).

- Willing to comply with the study visit schedule.

- Ages 15 to 39.

- Has access to a cellular telephone with text messaging capabilities.

- Has a current pair of spectacles.

- 'Neophyte' - In this work, 'neophyte' will be taken to mean any subject who has never been dispensed contact lenses. A subject who has taken part in a non-dispensing clinical study or has been fitted with contact lenses in practice but never went on to actually wear the lenses, will also be classified as a 'neophyte'.

- Spherical contact lens (CL) prescription between -0.75D and -6.00D and spectacle cylinder equal to or less than 0.75 DC.

- Monocular best-corrected distance visual acuity (VA) = 20/30 Snellen in each eye.

- Subject agrees to "intent" of wearing the CLs at minimum 6 hours/day for at least 4 days per week.

- They agree not to participate in other clinical research during the duration of this study.

Exclusion Criteria:

- Active ocular allergy, infection, injury, inflammation, or abnormality (e.g., keratoconus) that might interfere with soft contact lens wear.

- Prior corneal refractive surgery or corneal irregularity (e.g., keratoconus).

- Systemic disease, which might interfere with contact lens wear.

- Medication usage that may be associated with eye dryness.

- Use of any topical medication such as eye drops or ointment.

- Pregnant or lactating (by self-report).

- Aphakia.

- Grade 2 or greater of any of the following ocular surface signs: corneal edema, corneal vascularization, corneal staining, tarsal conjunctival changes or any other abnormality, which would normally contraindicate contact lens wear.

- Have participated in any other clinical trial or research in the two weeks prior to starting this study.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Narafilcon B Contact Lens

Spectacles
spectacle wearers

Locations

Country Name City State
United States Ohio State University Columbus Ohio

Sponsors (2)

Lead Sponsor Collaborator
Johnson & Johnson Vision Care, Inc. Ohio State University

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Papillary Conjunctivitis Swelling of the papillary (Papillary conjunctivitis) area of the eye was assessed using a slit-lamp. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score. 1 Year
Primary Conjunctival Hyperemia Comparison of the amount of redness in the conjunctival area of the eye, between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score. 1 Year
Primary Limbal Hyperemia Swelling of the vessels in the limbal area of the eye using a slit lamp. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score. 1 Year
Primary Corneal Staining Abrasions in the cornea area of the eye using a slit lamp. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. 1 Year
Primary Conjunctival Staining Mild abrasions of the conjunctival area of the eye. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score. 1 Year
Primary Corneal Neovascularization New vascularization of the Cornea. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score. 1 Year
Primary Differences in Subjective Comfort From the Contact Lens User Experience (CLUE) Questionnaire The subjective comfort questionnaire CLUE, assesses the overall lens comfort. The CLUE Questionnaire is a validated patient-reported outcomes questionnaire to assess patient-experience attributes of soft, disposable contact lenses in the US, ages 18-65. Scores follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response, with a range of 0-120. The differences between: (final visit and first visit) and then (final visit and 6 months) are reported. 1 Year
Secondary Comfortable Wearing Time Average numbers of overall average daily contact lens wear hours and average daily comfortable wear hours as reported at each follow-up visit. 1 Year
See also
  Status Clinical Trial Phase
Recruiting NCT04923841 - Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine N/A
Active, not recruiting NCT04080128 - Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control N/A
Active, not recruiting NCT05275959 - Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI) N/A
Completed NCT04604405 - Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation N/A
Recruiting NCT05594719 - The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow N/A
Completed NCT05594732 - The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow N/A
Completed NCT04492397 - Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI) N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Recruiting NCT06344572 - Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia Phase 3
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Active, not recruiting NCT05534022 - Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression. N/A
Completed NCT03934788 - the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT03701516 - Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2 N/A
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT03139201 - Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT02555722 - Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear N/A
Not yet recruiting NCT06009458 - Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear N/A
Recruiting NCT05548478 - Corneal Endothelial Cell Injury Induced by Mitomycin-C N/A