Clinical Trials Logo

Clinical Trial Summary

A randomized, controlled study with the pretest-posttest design was performed; 50 patients who were suffered from jaccoud's arthropathy and aged 30-50 years. Patients were randomly assigned into two groups: Group 1 (study group): received HILT, in addition to the routine physical therapy program. Group 2 (control group): received routine physical therapy program. All treatment interventions were applied at a frequency of three sessions per week for 8 weeks. The participants were recruited from the air forces hospital at the period from December 2018 and October 2019.


Clinical Trial Description

A sample of 55 female patients was recruited from the Kasr El-Ani hospital outpatient clinic to be treated in the outpatient clinic, Air forces hospital, Cairo. at the period from December 2018 and July 2019 with 50 of them completing the study. They were enrolled and assessed for their eligibility to participate in the study. The patients were randomly classified into 2 groups of equal number. Group 1 (Study group): received HILT, in addition to the routine physical therapy program. Group 2 (Control group): received routine physical therapy program. The patient's age ranged from 30 to 50 years. Elapsed time since the beginning of the disease was less than 1 year. All patients received the same medication. Patients were excluded if they had one or more of the following: positive rheumatic factor, circulatory disorders, neurological disease, diabetes, pregnant woman, communication problems or skin diseases.

The participants were informed in details about the nature, purpose, and benefits of the study, they had complete right to refuse or withdraw from the study at any time, and the confidentiality of any obtained information.

Interventions Patients indiscriminately assigned to study group (Group- 1):- 25 female Patients had been dealt with a received routine physical therapy program, in addition to HILT. Patients in the study group received pulsed Nd: YAG laser treatment, produced by a HIRO 3 device (ASA Laser, Arcugnano, Italy). The apparatus provided pulsed emission (1064 nm), very high peak power (3 kW), a high level of fluency (energy density; 360-1780 mJ/cm2), a short duration (120-150 μs), a mean power of 10.5 W, a low frequency (10-40 Hz), a duty cycle of about 0.1%, a probe diameter of 0.5 cm, and a spot size of 0.2 cm2 [9]. Twenty four treatment sessions with pulsed Nd: YAG laser were applied to the subjects of the study group, three sessions per week, over 8 weeks in succession via HIRO® 3.0 device (ASAlaser, Arcugnano, Vicenza, Italy). The device gives pulsed emission (λ = 1064 nm), maximum power (3000 W), fluency range (360-1780 mJ/cm2), pulse duration (≤ 100 μs), frequency range (10-40 Hz), maximum energy per pulse (350 mJ), mean power (10.5 W), and power cycle of ~0.1%. The device is equipped with a standard handpiece endowed with a fixed spacer and has a diameter of 0.5 cm and a spot size of 0.2 cm2. A pair of protective eye goggles were provided for the both the participant and the therapist. The participants were treated while assuming a sitting position, with their hand rested at the table. Every laser application comprised three phases: phase 1, where a fast scanning was applied transversely and longitudinally around the wrist and hand with three respective fluencies set at 510, 610, and 710 mJ/cm2 for a total of 300 J; phase 2, where a total of 10 fixed points around metacarpophalangeal joint and wrist joint were irradiated, in this phase, each point was radiated for 15 s, using a fluency of 710 mJ/cm2, 150 J/point, and a total of 150 J; and phase 3, where a scanning like that in phase 1 was applied, but at a much slower rate with a total energy of 300 J. The scanning energy density was 10 J/cm2 and the average irradiated area was 60 cm2. The control group (Group 2): 25 female Patients, in Group-B had been dealt with routine physical therapy program for 8 weeks, 3 sessions /week. Both groups received 24 sessions of treatment, 3 times per week for 8 weeks. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04244539
Study type Interventional
Source Jouf University
Contact
Status Completed
Phase N/A
Start date December 1, 2018
Completion date October 30, 2019

See also
  Status Clinical Trial Phase
Withdrawn NCT04976972 - A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation N/A
Recruiting NCT05546541 - Epidemiology and Nutrition
Completed NCT05071469 - Comparison of Two Different Treatment Methods N/A
Completed NCT05041400 - Distribution of Knee Isokinetic Angle-specific Moments and Ratios N/A
Not yet recruiting NCT06216028 - Bone Marrow Aspirate Concentrate (BMAC) Treatment for Knee Osteoarthritis Phase 3
Not yet recruiting NCT04932993 - Writing Down Goals N/A
Completed NCT02944448 - A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee Phase 2
Completed NCT02257489 - Phase 1 Study of ACE-083 in Healthy Subjects Phase 1
Completed NCT02269254 - Persona Versus NexGen N/A
Completed NCT02256098 - RSA RCT: ATTUNE™ TKA Versus PFC Sigma TKA N/A
Completed NCT01979731 - Effects Job Rotation in the Prevention of Work Related Musculoskeletal Disorders N/A
Active, not recruiting NCT01440153 - Additional Exercise Program in Professional Dancers N/A
Completed NCT00968266 - Improving Beliefs About Medication in Patients With Rheumatoid Arthritis N/A
Completed NCT05222126 - Efficacy of Ultrasound-Guided Hydrodissection in Carpal Tunnel Syndrome N/A
Completed NCT05062694 - Physical Therapy Management Of The Patient With Central Sensitization
Recruiting NCT05564182 - High Intensity Laser Therapy in the Treatment of Hemiplegic Shoulder Pain N/A
Completed NCT04009369 - Impacts of Physiotherapy Services in a Quebec Emergency Department N/A
Completed NCT05561452 - The Efficacy of PRP Injection in the Treatment of Rotator Cuff Syndrome N/A
Recruiting NCT05432609 - Standardization and Reproducibility Regarding Scanning Procedures and Measurements of Weight-bearing Cone Beam CT in the Lower Extremity
Completed NCT04959162 - The Effect of Theoretical Knowledge on Resident's Practical Performance in Musculoskeletal Ultrasound N/A