3 d scan sequence can realize continuous thin layer scanning, the thinnest layer thickness of 0.5 mm, to reduce the effects of partial volume effect and improve the spatial resolution image, the other 3 d sequence can according to need to multiplanar reconstruction based on the original image, the image of the watch is no longer limited to a fixed plane, and can avoid repeated scanning, reducing overall inspection time. Initially, 3D MRI uses gradient echo sequences (3D-GRE). Although the scan time of 3D-GRE is acceptable and has a high spatial resolution, the contrast between tissues is poor. In recent years, is voxel 3D fast spin-echo sequence (3D-FSE) has become an alternative 3D scanning sequence. Compared with the 3D-GRE sequence, 3D-FSE has better-intertissued contrast. However, there are still some problems in the application of 3D sequence in clinical practice. On the one hand, although 3D sequence reduces the overall scanning time, it increases the single scanning time, so it is easy to produce motion artifacts. On the other hand, although many studies have demonstrated the diagnostic efficacy of 3D sequences in the diagnosis of common intraarticular structural injuries, especially in the diagnosis of knee cartilage injuries, the diagnostic value of 3D sequences is comparable to that of conventional 2D-FSE sequences, but the evidence on whether 3D sequences can replace 2D sequences is still insufficient. Recently, a new fast signal acquisition technology -- Compressed Sensing (Compressed Sensing) technology has been gradually applied to many kinds of MRI sequences, and its application in 3D sequences can greatly shorten the single scan time. In this study, Modulated Flip Angle Technique in Refocused Imaging with Extended Echo was applied by United Imaging Co., Ltd. (Compressed Sensing) Train, 3D-Matrix), which is a fast self-selected echo sequence based on variable turn Angle technology, and its single scan time can be shortened to 5 minutes. 3 d sequence to more systematic evaluation on sports injury of knee joint application value, the investigators will study from within the bony structure of knee joint injury, joint structure damage and injury of the surrounding support structure aspects to discuss the diagnosis effect, and with arthroscopy for the gold standard to evaluate the accuracy of the 3 d structure within the sequence in the diagnosis of knee joint injury.


Clinical Trial Description

Magnetic resonance imaging (MRI) is the most important non-invasive examination method for the diagnosis of knee joint sports injury. 2D-FSE sequence is usually used for axial, sagittal and coronal scanning in MR examination of the knee joint. The sequence has good tissue contrast and spatial resolution. However, there are still some problems with 2D-FSE sequences. For example, the scanning layer thickness is usually up to 3-5mm, and there is a certain layer spacing, resulting in partial volume effect. In addition, in order to obtain images with different azimuths, the same sequence needs to be scanned for many times, which increases the overall inspection time. 3 d scan sequence can realize continuous thin layer scanning, the most thin layer thickness of 0.5 mm , so as to reduce the effects of partial volume effect and improve the spatial resolution image, the other 3 d sequence can be on the basis of the original image according to need multiplanar reconstruction, make the observation of the image is no longer limited to the fixed plane, and can avoid repeated scanning, reducing overall inspection time. Initially, 3D MRI uses gradient echo sequences (3D-GRE). Although the scan time of 3D-GRE is acceptable and has high spatial resolution, the contrast between tissues is poor. In recent years, the isosvoxel 3D fast spin echo sequence (3D-FSE) has become an alternative 3D scanning sequence. Compared with 3D-GRE sequence, 3D-FSE has better intertissue contrast . However, there are still some problems in the application of 3D sequences in clinical practice. On the one hand, although 3D sequences reduce the overall scanning time, the single scanning time increases. At present, the scanning time in most studies is generally 6-10 minutes , so motion artifacts are easily generated. On the other hand, although many studies have proved the diagnostic efficacy of 3D sequence in the diagnosis of common intraarticular structural injuries , especially the diagnostic value of 3D sequence in the diagnosis of knee cartilage injuries is equivalent to that of conventional 2D-FSE sequence, there is insufficient evidence on whether 3D sequence can replace 2D sequence . Recently, a new fast signal acquisition technology -- Compressed Sensing (Compressed Sensing) technology has been gradually applied to a variety of MRI sequences , and its application in 3D sequences can greatly shorten the single scan time. In this study, Modulated Flip Angle Technique in Refocused Imaging with Extended Echo was applied by United Imaging Co., Ltd. (Compressed Sensing) Train, 3D-Matrix), which is a fast self-selected echo sequence based on variable turn Angle technology, and its single scan time can be shortened to 5 minutes. 3 d sequence in order to more systematic evaluation on sports injury of knee joint application value, the investigators will study from within the bony structure of knee joint injury, joint structure damage and injury of the surrounding support structure aspects to discuss the diagnosis effect, and with arthroscopy for gold standard to evaluate the accuracy of the 3 d structure within the sequence in the diagnosis of knee joint injury. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04957043
Study type Observational
Source Peking University Third Hospital
Contact
Status Completed
Phase
Start date March 1, 2018
Completion date June 1, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT05036629 - Development of MRI Protocols and Associated Neuro-physiological Explorations in Healthy and Pathological Subjects N/A
Completed NCT02548819 - University Hospital Cardiac Device MR Registry: The Safety of MR Imaging in Patients With Implanted Cardiac Devices N/A
Completed NCT01168479 - FLAME: Investigate the Benefit of a Focal Lesion Ablative Microboost in Prostate Cancer Phase 3
Completed NCT00512226 - Iron Overload Assesment in Sickle Cell Anemia and Sickle Cell Thalassemia N/A
Recruiting NCT05439330 - Application of a Dental-dedicated MRI in the Diagnosis of Temporomandibular Joint Disorders, Tissue Alterations Related to Third Molars, Periapical and Periodontal Inflammatory Diseases, and Implant Treatment Planning N/A
Not yet recruiting NCT05464576 - Tumor Staging T of Bladder Tumours: Correlation of MRI and Anatomopathologic Analysis N/A
Recruiting NCT04034667 - Study of CT and MR in the Lung Cancer
Recruiting NCT04028375 - Study of CT and MR in the Gastric Cancer
Recruiting NCT04231175 - Dedicated MR Imaging vs Surgical Staging of Peritoneal Carcinomatosis in Colorectal Cancer N/A
Completed NCT00949507 - Comparison of Two Regimens of Anesthesia for Children Undergoing Magnetic Resonance Imaging (MRI) in General Anesthesia Phase 4
Completed NCT01420211 - Influence of the OATP1B1 and OATP1B3 Genotype on the Hepatic Uptake of Primovist® Phase 1/Phase 2
Recruiting NCT05167669 - Pain Relief in Symptomatic Bone Metastases With Adjuvant Hyperthermia MR Guided HIFU Early Phase 1
Recruiting NCT05618990 - OPTIMIZATION of ADVANCED MR SEQUENCES
Recruiting NCT05107232 - OSV-IRM - Volunteer MRI Sequence Optimization N/A
Completed NCT00556101 - Patient Acceptance of Whole Body Magnetic Resonance Angiography N/A
Recruiting NCT03142698 - Evaluation of 4 MRI Methods (PDFF 3, 6 and 11 Gradient Echoes and Spectroscopy) Compared to the Reference Method (Liver Biopsy) in Quantification of Hepatic Steatosis N/A
Suspended NCT00554073 - Whole Body Magnetic Resonance Angiography in Ischemic Patients at 1.5 and 3T N/A
Not yet recruiting NCT05359497 - Value of MRCP+ And Liver Multiscan in the Management of Dominant Strictures in Primary Sclerosing Cholangitis N/A
Recruiting NCT05192629 - Intranasal Dexmedetomidine Versus Oral Midazolam as Premedication for Propofol Sedation in Pediatric Patients Undergoing Magnetic Resonance Imaging Phase 3
Recruiting NCT04973423 - STUDY OF THE ADDED VALUE OF A TRANSMURAL EVALUATION IN PATIENTS WITH CROHN'S DISEASE UNDER BIOTHERAPY WITH CLOSE FECAL CALPROTECTIN FOLLOW-UP N/A