Clinical Trial Summary

To observe and evaluate the safety and efficacy of the GeminiOne Transcatheter Valve Edge-to-Edge Repair System in Patients With Moderate-severe or Severe Degenerative Mitral Regurgitation through a prospective, multicenter clinical trial using objective performance criteria.


Recruitment information / eligibility

Status Recruiting
Enrollment 120
Est. completion date November 24, 2029
Est. primary completion date November 24, 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Patients who volunteer to participate and sign an informed consent form, understand the purpose of the clinical trial and are able to cooperate throughout the trial process; 2. An age = 18 years; 3. Diagnostic transthoracic echocardiogram (TTE) obtained within 90 days and transesophageal echocardiogram (TEE) obtained within 180 days to determine the presence of symptomatic moderate-severe or severe degenerative mitral regurgitation (defined as mitral regurgitation grade =3+); 4. Patients' New York Heart Association (NYHA) cardiac function classification (see Appendix II) in grades II, III, or non-ambulatory grade IV; 5. Patients' left ventricular ejection fraction LVEF = 20%; 6. Patients considered to be at high surgical risk by the multidisciplinary cardiac team ; 7. Patients are anatomically suitable for mitral valve repair and suitable for the device under this study as assessed by the multidisciplinary cardiac team; Elements include, however, are not constrained to the following: 1. Mitral valve orifice area = 4.0 cm2; 2. Left ventricular end-systolic dimension (LVESD) = 60 mm; 3. The primary regurgitant bundle is a non-conjunctive regurgitant bundle and if the secondary regurgitant bundle is present, must be clinically insignificant; 4. Transeptal puncture and femoral venipuncture are feasible; The recommended reference criteria for high surgical risk are: an STS score of =8 for surgical valve replacement (see Appendix III) or an STS score of =6 for surgical valve repair, or the existence of other high-risk factors, such as the presence of other high-risk elements such as the presence of = 2 warning signs of moderate-severe frailty or the presence of feasible surgical operative limitations or the presence of = 2 main organs dysfunctions that cannot be elevated postoperatively or other surgical high-risk factors that are genuinely existing in the judgment of the independent cardiac surgeon in this study. Exclusion Criteria: 1. The presence of intra-cardiac space occupancy, thrombus, or bulky organisms as indicated by echocardiography; 2. The presence of other severe heart valve diseases requiring surgical intervention; 3. Leaflet anatomy that may prevent implantation of the valve clip, proper positioning on the leaflet, or prevent adequate reduction of mitral regurgitation by the valve clip. The assessment is based on transesophageal echocardiographic (TEE) mitral valve evaluation within 180 days prior to the subject's registration and includes: 1. inability of the valve clips to hold sufficient active leaflets; 2. lack of primary and secondary tendon support in the clamping area; 3. significant evidence of calcification in the clamping area; 4. significant fissures in the clamping area; 4. Active endocarditis, pericarditis, or rheumatic heart disease; or mitral valve leaflet changes resulting from endocarditis or rheumatic heart disease; 5. Severe right ventricular insufficiency (e.g. with symptoms of bilateral lower limb edema with increased jugular venous pressure and hepatomegaly); or pulmonary hypertension (pulmonary artery systolic pressure PASA > 70 mmHg as measured by echocardiography); 6. Patients who have had an acute coronary syndrome within 4 weeks, or untreated severe coronary artery stenosis requiring revascularization; 7. Patients with any cardiovascular intervention, cardiac surgery, cardiac resynchronization therapy (CRT, CRT-D), implantation of a buried cardioverter-defibrillator (ICD), etc. within 30 days; or have planned one of these procedures; 8. Patients underwent mitral valve surgery or mitral transcatheter valve surgery before, or have a left atrial appendage occluder device inside; 9. Patients with end-stage heart failure (ACC/AHA stage D), or after cardiac transplantation, or awaiting cardiac transplantation; 10. Patients who are hemodynamically unstable, defined as systolic blood pressure <90 mmHg without postload-reducing drugs, or in cardiogenic shock; or are requiring intra-aortic balloon counterpulsation, or other hemodynamic support drugs or devices; 11. Patients requiring emergency or urgent surgery for any reason; 12. Patients' femoral vein cannot accommodate a 22F catheter or overlaying ipsilateral deep venous thrombosis, as assessed by the investigator, or are anatomically unsuitable for atrial septum puncture; [13 13. Patients with active infection requiring concurrent antibiotic treatment; in the case of temporary disease, antibiotics must be discontinued for at least 14 days before enrollment; 14. Patients with a history of any cerebrovascular accident within 30 days; or a severe symptomatic carotid stenosis (carotid ultrasound suggesting >70% stenosis); 15. Modified Rankin Scale score = 4 (see Annex IV); 16. Patients with a history of acute peptic ulcer or gastrointestinal bleeding within 3 months; 17. Patients with hematological cachexia, including granulocytopenia (WBC <3 x 109/L), anemia (HB < 90 g/L), thrombocytopenia (PLT <50 x 109/L), bleeding disorders, and coagulopathy; or the presence of contraindications to antiplatelet or anticoagulant medication; 18. Patients with a contraindication to transesophageal echocardiography; or a contraindication to general anesthesia; 19. Patients with severe chronic obstructive pulmonary disease (COPD) requiring long-term steroids or continuous home oxygen therapy; 20. Patients with severe hepatic or renal insufficiency (ALT, AST, creatinine > 2 times the upper limit of normal values); 21. Pregnant or lactating women, or those with a birth plan within 12 months; 22. Patients with known hypersensitivity to device components or contrast media; 23. Patients enrolled in another clinical study and within the follow-up period; 24. Patients with a disease that would make the evaluation of treatment difficult (e.g. cancer, infection, severe metabolic disease, psychiatric disease, etc.); or patients with a life expectancy shorter than 12 months; 25. Patients whose compliance is assessed by the investigator to be poor and are unable to comply with the follow-up schedule and complete the examination; or other situations in which the investigator considers the issue to be unsuitable for participation in the study.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
GeminiOne Transcatheter Valve Edge-to-Edge Repair System
The transcatheter valve clamp system consists of a valve clamp, an adjustable bend mid-tube, and a manipulated inner tube. The adjustable bend introducer catheter consists of an adjustable bend outer tube and dilator. The valve clip is composed of nickel-titanium alloy, cobalt-chromium-nickel-molybdenum-iron alloy, and polyethylene terephthalate material and contains a closure clip, gripping tab, central mechanism, braid, and suture. The adjustable bend guiding catheter is used to provide access to the transcatheter valve clamping system and to reach the designated position. The adjustable curved mid-tube and manipulated inner tube are used to enable the delivery, gripping, and release process of the valve clips within the body.

Locations

Country Name City State
China Peiga Medical Technology (Suzhou) Co. Suzhou Jiangsu

Sponsors (1)

Lead Sponsor Collaborator
Peijia Medical Technology (Suzhou) Co., Ltd.

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Other Incidence of major adverse events (MAEs) MAE is defined as a combined clinical endpoint of death, stroke, myocardial infarction, renal failure, and nonelective cardiovascular surgery for device or procedure-related adverse events occurring after transseptal catheterization. 30 days, 6 months, and 12 months
Other All-cause mortality The percentage of all-cause death includes cardiac death, non-cardiac death, and death from unknown causes. 30 days, 6 months, and 12 months
Other Cardiac mortality The percentage of cardiac death 30 days, 6 months, and 12 months
Primary Treatment success Percentage of patients freedom from: death, surgery for valve dysfunction, and MR > 2+ (moderate to severe (3+) or severe (4+) mitral regurgitation) . 12 months
Secondary Acute procedural success Successful in GeminiOne implantation, and residual MR of 2+ or less at discharge. An echocardiography echocardiogram at 30 days can be accepted if the discharge image is not available or hard to interpret. A death before discharge or a re-operation of the mitral valve prior to 30 days is defined as acute procedure failure. Immediately after procedure, Discharge: 1 day after the patient's exit from the cardiac catheterization laboratory
Secondary Acute device success Rate of successful delivery and release of one or more GeminiOne devices with echocardiographic confirmation of leaflet clamping and successful withdrawal of the delivery catheter Immediately after procedure
Secondary Composite of function and re-operation measures Number of patients freedom from postoperative surgery for mitral valve dysfunction. 30 days, 6 months, and 12 months
Secondary Cardiac function change Number of patients with New York Heart Association (NYHA) Function Class I or II. 30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years
Secondary Quality of life improvement Change in quality of life (QoL) at 12 months over baseline, as measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ). 12 months
See also
  Status Clinical Trial Phase
Completed NCT03278574 - Flexible Band vs Rigid Ring for Degenerative Mitral Valve Disease N/A
Suspended NCT04960280 - A Study to Evaluate a Computerized Stethoscope Called ©Voqx to Diagnose Heart Disease N/A
Recruiting NCT05021614 - Valveclip® Transcatheter Mitral Valve Repair Study N/A
Not yet recruiting NCT06167213 - ALLIANCE Mitral: Safety and Effectiveness of SAPIEN X4 Transcatheter Heart Valve - Mitral N/A
Not yet recruiting NCT06465745 - AltaValve Pivotal Trial N/A
Withdrawn NCT05040451 - Carillon Mitral Contour System for Treatment of Exercise Induced Functional Mitral Regurgitation
Withdrawn NCT03714412 - Feasibility Study of Patients With Severe MR Treated With the Cardiovalve TMVR System N/A
Recruiting NCT02592889 - (MitraClip in Non-Responders to Cardiac Resynchronization Therapy) Phase 4
Completed NCT02355418 - The Role of Myocardial Fibrosis in Degenerative Mitral Regurgitation
Completed NCT01841554 - Cardioband With Transfemoral Delivery System N/A
Not yet recruiting NCT01431222 - Abrogation of Mitral Regurgitation Using the MitraClip System in High-Risk Patients Unsuitable for Surgery Phase 4
Not yet recruiting NCT03870516 - Left Chamber Function in Mitral Regurgitation and Predicting Outcome After Replacement and Targeting for Early Surgery N/A
Active, not recruiting NCT03230747 - SAPIEN M3 EFS: Early Feasibility Study of the Edwards SAPIEN M3 System for the Treatment of Mitral Regurgitation N/A
Enrolling by invitation NCT04031274 - Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter (AMTRAC) Valve Registry
Completed NCT05850026 - Mitral Regurgitation in Hypertrophic Obstructive Cardiomyopathy: Fix it in a Simple, Effective and Durable Way!
Completed NCT05836480 - Immediate Suboptimal Result of Mitral Valve Repair: Late Implications in a Matched Cohort Study
Completed NCT05836532 - Long Term Results of Surgical and Percutaneous Double Orefices Mitral Repair in Patient With p2 Prolapse Causing Degenerative Mitral Regurgitation
Recruiting NCT03975998 - Dutch-AMR: Early Mitral Valve Repair Versus Watchful Waiting in Asymptomatic Patients With Severe Mitral Regurgitation
Completed NCT01162083 - Identifying an Ideal Cardiopulmonary Exercise Test Parameter N/A
Suspended NCT00787293 - Study of Safety and Efficacy of the Percutaneous Reduction of Mitral Valve Regurgitation in Heart Failure Patients Phase 2