Clinical Trials Logo

Clinical Trial Summary

A within-subject cross-over study is done on eight completely edentulous patients to compare two different complete removable dentures. Group I: Heat cured Conventional complete dentures designed based on the neutral zone concept; Group II: CAD-CAM neutral zone complete dentures designed based on the neutral zone concept. Occlusal analysis is done by the T-Scan device, and evaluation of muscle activity is conducted by electromyography at insertion time, two weeks after insertion time, and one month after insertion time.


Clinical Trial Description

This study is designed as a randomized clinical trial applying a within-subject comparison of two different complete denture types as follows; group I: Heat cured Conventional complete dentures designed based on the neutral zone concept, group II: CAD-CAM neutral zone complete dentures designed based on the neutral zone concept. The study will be carried out on eight completely edentulous patients, each patient will receive two sets of complete dentures in a random sequence. For each denture set, at the denture insertion visit occlusal analysis and equilibration will be performed with the aid of the T-Scan device, also EMG evaluation of muscle activity will be conducted. Two weeks after, the patients will be recalled to reanalyze the occlusion after the denture settles using the T-scan computerized system. One month after the last recall visit, the EMG evaluation of muscle activity will be conducted again. The EMG and T-scan recording data will be collected and analyzed to compare the two denture types ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05990088
Study type Interventional
Source Ain Shams University
Contact Omnia MS Refai, PHD
Phone +201202420046
Email omnia_refaie@dent.asu.edu.eg
Status Recruiting
Phase N/A
Start date June 1, 2023
Completion date June 1, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT06007365 - Post Market Clinical FoIIow up (PMCF) Medical Device (MD) of Z-Systems Monotype Zirconia Dental Product: Z5m Dental Implants Registry
Completed NCT05350293 - Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height N/A
Completed NCT05359549 - Dental Implant Treatment for Two Adjacent Teeth in the Maxillary Aesthetic Region: an Evaluation After 10 Years
Completed NCT05650099 - Peri-implant Health of Dental Implants in the Posterior Region; an Evaluation After 10 Years
Completed NCT02239718 - Novel Use of 2-unit Cantilever Resin-bonded Bridges for Replacing Missing Molar Teeth - a Randomized Clinical Trial N/A
Recruiting NCT04581304 - The Use of Bio-Oss Collagen for Sinus Augmentation Using the Transcrestal Approach. N/A
Not yet recruiting NCT06033989 - Clinical and Radiographic Evaluation of the Effect of Hyaluronic Acid Surface Treatment Versus Sandblasted Acid Etched on Stability of Delayed Dental Implant in Posterior Maxilla. N/A
Completed NCT06178796 - Evaluation of the Effect of the Gap Between Bone and Implant Surface on the Implants Stability N/A
Recruiting NCT05649085 - Evaluation of Single-unit Implant-supported Prostheses Survival Using CoCr Prosthetic Abutments: Prospective Observational Study
Completed NCT02123420 - Platform Switching vs Regular Platform Implants. One Year Results From a RCT N/A
Active, not recruiting NCT05362591 - Anterior Resin Bonded Restorations for Adolescent N/A
Active, not recruiting NCT04378140 - Retention and Durability of the Anterior Zirconia Wing Bridge
Completed NCT01953991 - OHQoL With Removable Partial Dentures; a Pilot Study N/A
Active, not recruiting NCT01229995 - Randomized Controlled Clinical Trial of CAD/CAM and Conventionally Fabricated Singl Implant Abutments. N/A
Recruiting NCT04908618 - The Accuracy of Conventional Versus Digital Implant Impression Techniques N/A
Completed NCT05476848 - Relationship Between Oral Findings and Salivary Factors in Sars-Cov-2 Patients N/A
Completed NCT05403099 - Effect of Topical Application of Hyaluronic Acid on Stability of Immediate Loading Dental Implant in Posterior Maxilla N/A
Completed NCT03198520 - REFRAME RPD Post-Market Clinical Study N/A
Active, not recruiting NCT06334081 - Different Surgical Drilling Protocols in Posterior Maxilla N/A
Completed NCT03877419 - Comparison of Different Drilling Speed to Classify Bone Quality by Tactile Sensation on a Saw Bone Model