Missing Teeth Clinical Trial
Official title:
Comparison of Electromyographic Muscle Activity and Occlusal Accuracy Between Conventional and CAD/CAM Complete Dentures Designed Based on Neutral Zone Concept (Randomized Controlled Clinical Trial)
A within-subject cross-over study is done on eight completely edentulous patients to compare two different complete removable dentures. Group I: Heat cured Conventional complete dentures designed based on the neutral zone concept; Group II: CAD-CAM neutral zone complete dentures designed based on the neutral zone concept. Occlusal analysis is done by the T-Scan device, and evaluation of muscle activity is conducted by electromyography at insertion time, two weeks after insertion time, and one month after insertion time.
This study is designed as a randomized clinical trial applying a within-subject comparison of two different complete denture types as follows; group I: Heat cured Conventional complete dentures designed based on the neutral zone concept, group II: CAD-CAM neutral zone complete dentures designed based on the neutral zone concept. The study will be carried out on eight completely edentulous patients, each patient will receive two sets of complete dentures in a random sequence. For each denture set, at the denture insertion visit occlusal analysis and equilibration will be performed with the aid of the T-Scan device, also EMG evaluation of muscle activity will be conducted. Two weeks after, the patients will be recalled to reanalyze the occlusion after the denture settles using the T-scan computerized system. One month after the last recall visit, the EMG evaluation of muscle activity will be conducted again. The EMG and T-scan recording data will be collected and analyzed to compare the two denture types ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT06007365 -
Post Market Clinical FoIIow up (PMCF) Medical Device (MD) of Z-Systems Monotype Zirconia Dental Product: Z5m Dental Implants Registry
|
||
Completed |
NCT05350293 -
Evaluation of the Abutment Type Following Oral Implants in Terms of the Surrounding Bone Height
|
N/A | |
Completed |
NCT05650099 -
Peri-implant Health of Dental Implants in the Posterior Region; an Evaluation After 10 Years
|
||
Completed |
NCT05359549 -
Dental Implant Treatment for Two Adjacent Teeth in the Maxillary Aesthetic Region: an Evaluation After 10 Years
|
||
Completed |
NCT02239718 -
Novel Use of 2-unit Cantilever Resin-bonded Bridges for Replacing Missing Molar Teeth - a Randomized Clinical Trial
|
N/A | |
Recruiting |
NCT04581304 -
The Use of Bio-Oss Collagen for Sinus Augmentation Using the Transcrestal Approach.
|
N/A | |
Not yet recruiting |
NCT06033989 -
Clinical and Radiographic Evaluation of the Effect of Hyaluronic Acid Surface Treatment Versus Sandblasted Acid Etched on Stability of Delayed Dental Implant in Posterior Maxilla.
|
N/A | |
Completed |
NCT06178796 -
Evaluation of the Effect of the Gap Between Bone and Implant Surface on the Implants Stability
|
N/A | |
Recruiting |
NCT05649085 -
Evaluation of Single-unit Implant-supported Prostheses Survival Using CoCr Prosthetic Abutments: Prospective Observational Study
|
||
Completed |
NCT02123420 -
Platform Switching vs Regular Platform Implants. One Year Results From a RCT
|
N/A | |
Active, not recruiting |
NCT05362591 -
Anterior Resin Bonded Restorations for Adolescent
|
N/A | |
Active, not recruiting |
NCT04378140 -
Retention and Durability of the Anterior Zirconia Wing Bridge
|
||
Completed |
NCT01953991 -
OHQoL With Removable Partial Dentures; a Pilot Study
|
N/A | |
Active, not recruiting |
NCT01229995 -
Randomized Controlled Clinical Trial of CAD/CAM and Conventionally Fabricated Singl Implant Abutments.
|
N/A | |
Recruiting |
NCT04908618 -
The Accuracy of Conventional Versus Digital Implant Impression Techniques
|
N/A | |
Completed |
NCT05476848 -
Relationship Between Oral Findings and Salivary Factors in Sars-Cov-2 Patients
|
N/A | |
Completed |
NCT05403099 -
Effect of Topical Application of Hyaluronic Acid on Stability of Immediate Loading Dental Implant in Posterior Maxilla
|
N/A | |
Completed |
NCT03198520 -
REFRAME RPD Post-Market Clinical Study
|
N/A | |
Active, not recruiting |
NCT06334081 -
Different Surgical Drilling Protocols in Posterior Maxilla
|
N/A | |
Completed |
NCT03877419 -
Comparison of Different Drilling Speed to Classify Bone Quality by Tactile Sensation on a Saw Bone Model
|