Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT03777280
Other study ID # CEBD-CU-2018-11-27
Secondary ID
Status Not yet recruiting
Phase N/A
First received
Last updated
Start date January 1, 2019
Est. completion date July 1, 2019

Study information

Verified date December 2018
Source Cairo University
Contact haytham mo talaat, master
Phone +201210520141
Email haythamtalaat.zb@gmail.com
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

This study is aiming to evaluate the retentive forces in PEEK framework RPD compared to Cobalt-Chrome framework RPD during attachment/detachment cycles in mandibular kennedy class I edentulous cases


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 30
Est. completion date July 1, 2019
Est. primary completion date April 1, 2019
Accepts healthy volunteers No
Gender All
Age group N/A and older
Eligibility Inclusion Criteria:

- . kennedy class I edentulous subjects indicated for framework partial denture

Exclusion Criteria:

- Uncooperative patients and bad oral hygiene patients

Study Design


Related Conditions & MeSH terms


Intervention

Device:
peek framework RPD
it is a polyetheretherketone polymer frame combined with acrylic resin denture teeth and a conventional acrylic resin denture base made by injecting technique and have several advantages regarding strength and esthetics
cobalt chromium framework RPD
standard framework device

Locations

Country Name City State
Egypt Faculty of Oral and Dental Medicine Cairo University Cairo Manial

Sponsors (1)

Lead Sponsor Collaborator
Cairo University

Country where clinical trial is conducted

Egypt, 

References & Publications (1)

Souza JE, Silva NR, Coelho PG, Zavanelli AC, Ferracioli RC, Zavanelli RA. Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP titanium in a cast framework association of removable partial overdenture. J Contemp Dent Pract. 2011 May 1;12(3):179-86. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Retention retention force of RPD during attachment/detachment cycles measured by digital force meter device change from baseline retention force after one month and after three months
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04868825 - Safety and Efficacy Evaluation of the Ivory Dentin Graft Device (IvoryGraft) - Long Term Follow-Up N/A
Completed NCT03150472 - Safety and Efficacy Evaluation of the Ivory Dentin Graft Device N/A
Not yet recruiting NCT03777345 - Comparison Between Injection Molded Polyetheretherketone (PEEK) Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Periodontal Health of Abutment Teeth N/A
Not yet recruiting NCT03777423 - Comparison Between Injection Molded PEEK Framework and Cobalt Chromium Framework Removable Partial Dentures Regarding Biting Force N/A
Completed NCT02736994 - Assessment of the Impact of Probiotics on Biofilm Formation on Removable Acrylic Dentures N/A