Renal Failure Clinical Trial
Official title:
Tandem Polyurethane Stents Compared to Single Silicone Stent for Malignant Ureteral Obstruction
Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival.
Malignant ureteral obstruction (MUO) is an extrinsic ureteral obstruction caused by malignant diseases. MUO may induce renal failure, which would be a barrier to several therapies including chemotherapy. Indwelling double-pigtail polymeric ureteral stent is a common method to release renal obstruction, but does not necessarily guarantee renal decompression as most studies reported stent failure with a mean of 30% at a mean time of three months [1-3]. Various endoscopic strategies have been proposed to increase time to failure, including tandem polymeric stents, metallic spiral coil stent, self-expanding Nitinol stent and polymeric stents with different lumen diameter and stiffness [4-7]. However, heterogeneity of MUO, low number of patients, unspecified polymer type, retrospective studies and the lack of a standard method to assess stent failure limit robust comparative analysis. Tandem ureteral stents (TUS) technique uses two polymeric ureteral stents passed simultaneously to better withstand the presumed compressive forces that overcome conventional single stent. This method offers an additional parallel lumen and allows more extraluminal flow between the two stents [6]. In a study on TUS in 39 renal units with MUO, two 6 Fr stents were inserted. Stent failure, defined by flank pain with increasing creatinine level or worsening hydronephrosis during 3 months after stents insertion, was occurred in 4% of cases [7]. This low failure rate compares favorably with the reported rates with single 6Fr polymeric stent or metallic stent. However, stents irritation, defined by profound lower urinary tract symptoms or renal colic in the absence of worsening hydronephrosis or infection, was reported in 29-85% of patients [7,8]. Silicon stent, which is considered biocompatible and soft, has the potential to be less irritative. In a recent systematic review, silicone stents has less stent-related symptoms in comparison to non-silicone polymers and ''hard'' stents. [9]. However, silicone has high susceptibility to compression, which in case of MUO may results in lower drainage efficacy. This study aim to compare tandem 6 Fr Percuflex™ stents and single large-caliber 8Fr silicone stent in patients with MUO. The primary endpoint is stent failure rate. The secondary endpoints are patient comfort, quality of life and overall survival. References: 1. Docimo SG, Dewolf WC. High failure rate of indwelling ureteral stents in patients with extrinsic obstruction: experience at 2 institutions. J Urol. 1989;142(2 Pt 1):277-279. doi:10.1016/s0022-5347(17)38729-3 2. Vogt B, Blanchet LH. Analysis of Ureteral Tumour Stents for Malignant Ureteral Obstruction: Towards Reshaping an Optimal Stent. Res Rep Urol. 2021;13:773-782. Published 2021 Oct 27. doi:10.2147/RRU.S334277 3. Chung SY, Stein RJ, Landsittel D, et al. 15-year experience with the management of extrinsic ureteral obstruction with indwelling ureteral stents. J Urol. 2004;172(2):592-595. doi:10.1097/01.ju.0000130510.28768.f5 4. Patel C, Loughran D, Jones R, Abdulmajed M, Shergill I. The resonance® metallic ureteric stent in the treatment of chronic ureteric obstruction: a safety and efficacy analysis from a contemporary clinical series. BMC Urol. 2017;17(1):16. Published 2017 Mar 10. doi:10.1186/s12894-017-0204-8 5. Khoo CC, Ho C, Palaniappan V, et al. Single-Center Experience with Three Metallic Ureteral Stents (Allium® URS, Memokath™-051, and Resonance®) for Chronic Ureteral Obstruction. J Endourol. 2021;35(12):1829-1837. doi:10.1089/end.2021.0208 6. Fromer DL, Shabsigh A, Benson MC, Gupta M. Simultaneous multiple double pigtail stents for malignant ureteral obstruction. Urology. 2002;59(4):594-596. doi:10.1016/s0090-4295(01)01646-7 7. Elsamra SE, Motato H, Moreira DM, et al. Tandem ureteral stents for the decompression of malignant and benign obstructive uropathy. J Endourol. 2013;27(10):1297-1302. doi:10.1089/end.2013.0281 8. Shvero A, Haifler M, Mahmud H, Dotan Z, Winkler H, Kleinmann N. Quality of life with tandem ureteral stents compared to percutaneous nephrostomy for malignant ureteral obstruction. Support Care Cancer. 2022;30(11):9541-9548. doi:10.1007/s00520-022-07354-2 9. Boeykens M, Keller EX, Bosio A, et al. Impact of Ureteral Stent Material on Stent-related Symptoms: A Systematic Review of the Literature. Eur Urol Open Sci. 2022;45:108-117. Published 2022 Oct 19. doi:10.1016/j.euros.2022.09.005 ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02763410 -
Impact of the Composition of Packed Red Blood Cell Supernatant on Renal Dysfunction and Posttransfusion Immunomodulation
|
||
Active, not recruiting |
NCT03183245 -
Comparison of the Human Acellular Vessel (HAV) With Fistulas as Conduits for Hemodialysis
|
Phase 3 | |
Completed |
NCT04084301 -
Impact of Cardiopulmonary Bypass Flow on Renal Oxygenation, Blood Flow and Tubular Injury
|
N/A | |
Completed |
NCT03292029 -
Pilot Medical Evaluation of the T50 Test
|
N/A | |
Suspended |
NCT04589065 -
SCD for CRS in Congestive Heart Failure (CHF) (No Left Ventricular Assist Device)
|
N/A | |
Completed |
NCT03806998 -
Effects of a Ketoacid Supplementation in Patients With Stage III to IV Renal Failure
|
Phase 3 | |
Active, not recruiting |
NCT03672110 -
Slow and Low Start of a Tacrolimus Once Daily Immunosuppressive Regimen
|
Phase 3 | |
Completed |
NCT02325726 -
RRI Compared With NephroCheckTM to Predict Acute Renal Failure After Cardiac Surgery.
|
N/A | |
Completed |
NCT02116270 -
Accelerated Immunosenescence and Chronic Kidney Disease
|
N/A | |
Completed |
NCT01859273 -
Adherence Enhancement for Renal Transplant Patients
|
N/A | |
Completed |
NCT01388270 -
Effect of a Pre Heparin Coated Dialysis Filter on Coagulation During Hemodialysis
|
Phase 4 | |
Completed |
NCT01476995 -
Prognostic Indicators as Provided by the EPIC ClearView
|
N/A | |
Completed |
NCT01187953 -
Double-Blind,Double-Dummy,Efficacy/Safety,LCP-Tacro™ Vs Prograf®,Prevention Rejection,De Novo Adult Kidney Tx
|
Phase 3 | |
Completed |
NCT00966615 -
The Effect of Neutral Peritoneal Dialysis (PD) Solution With Minimal Glucose-Degradation-Product (GDP) on Fluid Status and Body Composition
|
Phase 4 | |
Completed |
NCT01008631 -
The Pharmacologic Profile of Sodium Thiosulfate in Renal Failure and Healthy Volunteers
|
N/A | |
Completed |
NCT00765661 -
Pharmacokinetics of LCP-Tacro(TM) Once Daily And Prograf® Twice A Day in Adult De Novo Kidney Transplant Patients
|
Phase 2 | |
Completed |
NCT00737672 -
GORE VIABAHN Endoprosthesis Versus Percutaneous Transluminal Angioplasty (PTA) to Revise AV Grafts in Hemodialysis
|
Phase 3 | |
Completed |
NCT00808691 -
Microcirculation and Oxidative Stress in Critical Ill Patients in Surgical Intensive Care Unit
|
N/A | |
Recruiting |
NCT00470769 -
The Efficacy of Color-Doppler Ultrasonography to Assess the Renal Blood Flow With the Estimation of GFR
|
N/A | |
Terminated |
NCT00338455 -
Natrecor (Nesiritide) in Transplant-Eligible Management of Congestive Heart Failure-TMAC
|
Phase 2 |