Clinical Trial Summary

The purpose of this research is to evaluate novel technologies for the assessment of ocular structure and function, including the scanning device called Optical Coherence Tomography (OCT). We will test the OCT and other devices in their ability to image diseases of the eye and also compare the measurements made with OCT to those of other imaging and visual field devices approved by the Food and Drug Administration (FDA). OCT may be useful for the early diagnosis and monitoring of a variety of types of eye diseases


Clinical Trial Description

Objective: The purpose of this research is to evaluate a new technology, optical coherence tomography (OCT), to image diseases of the eye and to compare the measurements obtained using OCT with those of other imaging and visual field devices. OCT may be useful for the early diagnosis and monitoring of a variety of eye diseases such as age-related macular degeneration (ARMD), glaucoma, diabetic retinopathy, macular edema, and other pathologies. Specific Aims: There are four sub-studies: cross-sectional, longitudinal, reproducibility, and an Alzheimer's Disease (AD) sub-study. The cross-sectional and longitudinal arms study the effectiveness of the OCT technology in terms of detecting and monitoring eye diseases. The reproducibility study is designed to test the measurement likeness of the OCT. The AD sub-study will use high resolution ocular imaging technologies to determine ocular biomarkers for sensitive detection of AD. Background: This is a continuation of an ongoing study from the New England Eye Center (NEEC), Tufts Medical Center, Boston, MA. This study started when our research group was located at NEEC and in collaboration with the Massachusetts Institute of Technology (MIT) where we conducted the first clinical studies with OCT. The first investigation using OCT was published in Science in 1991 and showed in vitro imaging of the human retina and atherosclerotic plaque. We developed an OCT prototype system for performing preliminary ophthalmic clinical studies and in 1993, began clinical OCT imaging studies. The prototype ophthalmic OCT instrument acquired OCT images of the retina with an axial resolution of 10µm within an acquisition time of 2.5 sec. The OCT imaging system was integrated with a slit-lamp biomicroscope for in vivo tomography of the anterior and posterior eye. The beam is directed into the eye using computer controlled galvonometric scanners, which can scan arbitrary transverse patterns. The beam focus is coincident with the slit-lamp image plane to permit simultaneous scanning and visualization of the eye through the slit-lamp or via a CCD camera. For tomography of the anterior eye, the microscope is focused directly on the structure, while for retinal imaging, a lens relay images of the retina onto the slit-lamp image plane. A computer provides real-time display of the tomogram, image processing, and data management. OCT technology was patented and subsequently transferred to industry (Zeiss Humphrey Systems, CA). Our prototype ophthalmic OCT system was developed into a clinical instrument and was introduced into the ophthalmic market in 1996. The commercial OCT technology has an axial resolution of 10 µm and can acquire a 100 transverse pixel retinal tomogram in 1 second. A third generation ophthalmic OCT imaging device, OCT3, was introduced three years ago. OCT imaging is now used as a standard diagnostic procedure as part of an ophthalmic examination for many retina and glaucoma patients at the University of Pittsburgh Medical Center (UPMC) Eye Center and New England Eye Center (NEEC). OCT imaging is in use in major research and clinical centers internationally. The OCT has been approved by the Food and Drug Administration for use in ophthalmology. Significance: OCT enables tissue pathology to be imaged in situ and in real time with a resolution approaching that of conventional histopathology but without the need for excising and processing specimens. OCT provides a quantitative method of directly measuring ocular structures with high precision and could provide an objective, early diagnosis for glaucoma, age related macular degeneration (ARMD), diabetic retinopathy, macular edema, and other pathologies. Extensive studies have been performed with OCT in cross-sectional as well as longitudinal setting. In this ongoing protocol, our objective is to continue these studies using the commercial ophthalmic OCT imaging instruments to develop methods for early detection and improve longitudinal assessment for the above mentioned ocular pathologies. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00286637
Study type Observational
Source NYU Langone Health
Contact
Status Completed
Phase
Start date January 1995
Completion date February 19, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A
Completed NCT02520674 - Glaucoma Screening With Smartphone Ophthalmology N/A
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3
Completed NCT02653963 - Triamcinolone for Ahmed Glaucoma Valve N/A