Low Cardiac Output Clinical Trial
Official title:
Validation of Measurement of Cardiac Output With LiDCO Rapid and TEE (Trans Esophageal Echocardiography) by Comparing With Intermittent Thermodilution Technique in Cardiac Surgical Patients
Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output. Investigators would like to compare the most popular minimally-invasive devices used to measure cardiac output using arterial waveform: LiDCO Rapid and TEE with the thermodilution method at various phases of the cardiac surgery.
Measurement of the cardiac output is one of the important hemodynamic monitoring tools in
cardiac surgery. It helps determine the type of medications needed to maintain optimal
hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary
artery catheter is considered has the gold standard for the measurement of cardiac output,
however over the past 10 to 15 years it has been questioned about its safety and efficacy.
There has been a surge in recent years of less invasive devices capable of measuring cardiac
output by various means, including bioimpedance, transpulmonary thermodilution,
transthoracic and transesophageal echocardiography, and arterial waveform analysis.
There is a variety of devices currently available for cardiac output measurement by
arterial-waveform analysis. These devices have been compared to each other, and to the
pulmonary artery catheter as the gold standard. However, the companies manufacturing these
devices have made software upgrades that they believe improves their performance. No studies
have been performed comparing the uncalibrated arterial waveform based cardiac output
measurement device,LiDCORapid since the software upgrades. In addition to baseline cardiac
output measurements, Investigators intend to study the effect of volume loading (by
trendelenburg position), sympathetic stimulus (incision), a vasodilated state (15 minutes
after separation from CPB) and chest closure on cardiac output measured by the three
different techniques.
In addition to cardiac output the investigators would like to measure stroke volume
,Systemic Vascular Resistance, stroke volume variation with LiDCO . The main purpose is to
validate the accuracy of measurements by these two minimally-invasive methods in comparison
with thermodilution method in various hemodynamic states.
;
Observational Model: Case-Only, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT01157299 -
Hemodynamic Evaluation of Preload Responsiveness in Children by Using PiCCO
|
N/A | |
Completed |
NCT01857999 -
Losartan in Decompensated Heart Failure
|
Phase 4 | |
Terminated |
NCT00524862 -
Standard Drug Therapy vs. Implanted Defibrillator for Primary Prevention of Sudden Cardiac Death
|
N/A | |
Completed |
NCT00529490 -
Efficacy, Safety of Hypertonic Lactate Soln. as Fluid Resuscitation Compared With Ringer's Lactate in Post-CABG Pats
|
Phase 3 | |
Completed |
NCT02433379 -
Understanding Outcomes With the EMBLEMâ„¢ S-ICD in Primary Prevention Patients With Low Ejection Fraction
|
N/A | |
Completed |
NCT00586027 -
Is There a Correlation of Natriuretic Propeptide Type B With an Intraoperative Low Cardiac Output?
|
N/A | |
Completed |
NCT00529711 -
The Efficacy of Hypertonic Lactate Solution in CABG(Coronary Artery Bypass Grafting) Patients
|
Phase 3 | |
Completed |
NCT02599376 -
Comparative Study of Haemodynamic Changes After Spinal Anaesthesia in Non-obese and Pregnant Women
|
N/A | |
Completed |
NCT02529033 -
Hemodynamic Survey Cardiac Surgical Scenarios
|
||
Withdrawn |
NCT00167440 -
Comparison of Techniques for Assessing Cardiac Output and Preload in Critically Ill Pediatric Patients
|
Phase 3 | |
Active, not recruiting |
NCT02422342 -
Comparison Study of Non-invasive Measurement of Blood Pressure and Cardiac Output During Stress Echocardiography
|