Liver Neoplasms Clinical Trial
Official title:
The eValuation of Image Guidance of Stereotactic Body Radiotherapy Using Ultrasound: Assessment in Liver
Worldwide, primary liver cancer is the 3rd most common cause of cancer-related death, accounting for 6% of cancer diagnoses. In the UK, the number of cases reported has more than trebled since the 1970's, with 5550 new cases in 2014 (CRUK statistics 2014). Liver transplant or surgery are the main forms of treatment offered but only less than 20% of patients can tolerate these treatments. There is a need for non-surgical therapies that would improve these patients' chances of survival. Radiotherapy has been shown to increase the likelihood of liver cancer cure. To deliver radiotherapy safely to the patient, the radiation must be delivered to the liver cancer only, avoiding normal liver tissues and other surrounding normal tissues. Because the liver moves during breathing, a liver cancer will also move during radiotherapy. To accurately target the cancer the patient can be asked to hold their breath during treatment to stop the motion. Or motion of the cancer can be monitored and the radiation beam can be moved to follow its motion. The investigators are investigating new methods to either: (a) ensure that when the patient repeats their breath hold the cancer is in the same position each time, or (b) measure the motion of the liver cancer whilst the patient breathes freely. It is not clear which is the best method and therefore are investigating both approaches. Ultrasound is a non-invasive and real-time imaging method that can easily be used to image the liver and may be able to perform both of these tasks. In this study the investigators will test ultrasound equipment, which has been specifically designed to guide radiotherapy. 26 healthy volunteers will be recruited to help evaluate the accuracy of ultrasound to measure the position of the liver in breath hold and in free breathing.
PURPOSE: This observational study of healthy volunteers will test the use of a safe,
non-ionising and non-invasive imaging system for the purpose of improving radiotherapy
treatment of the liver. This study investigates an image guidance method which may be used to
guide liver radiotherapy and enable more accurate treatment on a conventional radiotherapy
machine.
RECRUITMENT: Volunteers will need to provide their National Health Service (UK) numbers and
be registered on the hospital information system. Volunteers need to be aware that if they
are patients at the Royal Marsden Hospital this may raise confidentiality issues. Volunteers
will be made aware of this in the recruiting email and the Volunteer Information sheet.
USE OF HEALTHY VOLUNTEERS: This is an observational study, which tests the use of an
ultrasound guidance system. The accuracy of the system will be evaluated by comparison of
proprietary methods of liver position estimation against a manually derived ground truth
derived from the images of the liver acquired in participants. It is not expected that there
are any differences in the ultrasound guidance images of healthy volunteers and patients with
liver cancer. Ultrasound is a non-invasive and non-ionizing imaging modality with no known
side-effects or complications and therefore, safe to use in a volunteer study. Furthermore,
this study requires that participants lie on a hard couch for up to 45 minutes and up to 4
times. This would be challenging for the vast majority of patients with liver cancer who are
most likely to be frail due to their disease.
REVIEW OF HEALTHY VOLUNTEERS: The ultrasound guidance system provides 3D ultrasound images of
the liver for providing positional information only. It is very unlikely that abnormalities
will be detectable on 3D US guidance images. These images are not of diagnostic quality,
being lower resolution than routine diagnostic 2D ultrasound images. Furthermore, diagnostic
ultrasound of the liver often incorporates ultrasound contrast agent, which will not be used
in this study. If a radiographer does observe any abnormality, this will be reported to a
Consultant Radiologist and the images will be made available for review.
RISKS, BURDENS and BENEFITS: There is very little risk associated with ultrasound and the
Automatic Breathing Control (ABC) device, both pieces of the equipment are CE-marked and we
are not using outside of their respective intended purposes. The burden to the volunteer is
(1) the time spent, (2) the uncomfortable nature of the couch (it has a hard flat surface)
and (3) discomfort using the ABC device. The participant will made aware of (1), (2) and (3)
by providing details in the volunteer information sheet. Participants who are uncomfortable
using the ABC can opt out and still participate in the study. Participants will be able to
get up from the couch and walk around to relive any discomfort at any point during the
imaging sessions.
There are no benefits for the participants. It is expected that this study will be of benefit
to future patients with liver cancer. To ensure there is no perceived benefit of the
acquisition of ultrasound images it is stated clearly in the volunteer information sheet that
images are not of diagnostic quality and that persons obtaining the images are trained in
therapy guidance and not diagnostics, and that images will only be reviewed by a radiologist
in the unlikely event that an abnormality is observed.
CONFLICTS OF INTEREST: There are no conflicts of interest. No study investigator will benefit
financially from the outcome of this study. The manufacturer of the Clarity ultrasound system
will be informed of the results and all results will be published in a peer-reviewed
scientific journal.
ACCESS to DATA: The investigators wish to make anonymised image data available to other
researchers on request for the purpose of medical research. This is intended to maximise the
value of the data and may provide greater benefit to patients. Volunteers will be asked to
consent to their anonymised data being made available to other researchers.
AIMS: This study aims to develop and evaluate the use of 3 ultrasound (3DUS) to estimate the
liver position for radiotherapy guidance. This is an exploratory study, where Clarity US of
the abdomen will be acquired in healthy volunteers. 3D US-sim, 3D US-guide, 3D US-monitor and
4D US-monitor will be used to meet the following study objectives:
1. The accuracy of B-mode 3D US-guide, to estimate the position of the liver in breath-hold
for verification of (1) daily set-up position (set-up US-guide) and (2) repeat breath
hold relevant to radiotherapy delivery (BH 3D US-monitor), will be determined. Accuracy
will be assessed by comparison of US-guide and US-monitor determined liver position with
a manually determined 'gold standard' liver position.
2. Comparison of the accuracy of power Doppler and B-mode US-guide/US-monitor for the
estimation of liver position during breath hold.
3. Assessment of the accuracy of 4D US-monitor to estimate liver motion during free
breathing (FB).
4. Comparison of liver position stability using spirometry and voluntary breath-hold (vBH)
using US-monitoring.
5. Assessment of the availability of a second or third ultrasound field of view for
increasing the accuracy of US-guide based estimates of liver motion.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT03651154 -
Hypovolemic Phlebotomy to Reduce Blood Transfusions in Major Hepatic Resections
|
N/A | |
Not yet recruiting |
NCT02521129 -
A New Track Ablation Device for Liver Biopsy: A Feasibility Study
|
Phase 1/Phase 2 | |
Not yet recruiting |
NCT02168608 -
Remote Ischemia Precondition (RIPC) for Hepatic Protection in Patients Undergoing Hepatectomy
|
N/A | |
Enrolling by invitation |
NCT01465425 -
Extracolonic Findings on Computed Tomography (CT) Colonography
|
||
Active, not recruiting |
NCT01177007 -
Intra-arterial Y-90 TheraSpheres for Hepatic Metastases From Solid Tumors
|
Phase 2 | |
Completed |
NCT00788697 -
SonoVue®-Enhanced Ultrasound Versus Unenhanced US for Focal Liver Lesion Characterization
|
Phase 3 | |
Recruiting |
NCT01564810 -
Cetuximab in Combination With Chemotherapy for the Treatment of Metastatic Colorectal Cancer
|
Phase 4 | |
Completed |
NCT00094003 -
Study of NS-9 in Patients With Liver Metastases
|
Phase 1 | |
Terminated |
NCT00051532 -
Seocalcitol Versus Placebo in Advanced Hepatocellular Carcinoma
|
N/A | |
Completed |
NCT00001587 -
A Phase I Study of Isolated Hepatic Portal and Arterial Perfusion (IHP) With Escalating Dose Melphalan for Primary or Metastatic Unresectable Cancers of the Liver
|
Phase 1 | |
Completed |
NCT00222664 -
Qidong Hepatitis B Intervention Study
|
Phase 4 | |
Recruiting |
NCT04518852 -
TACE, Sorafenib and PD-1 Monoclonal Antibody in the Treatment of HCC
|
Phase 2 | |
Completed |
NCT03289273 -
Observational Study to Evaluate, Under Real-world Practice Conditions, the Safety and Effectiveness of Regorafenib in Patients Diagnosed With Unresectable Hepatocellular Carcinoma (uHCC)
|
||
Terminated |
NCT03349255 -
Clinical Study of ET1402L1-CAR T Cells in AFP Expressing Hepatocellular Carcinoma
|
Phase 1 | |
Recruiting |
NCT05068180 -
Low-dose Neuroleptanalgesia for Postoperative Delirium in Elderly Patients
|
Phase 4 | |
Recruiting |
NCT03715517 -
Spinal Anesthesia For Enhanced Recovery After Liver Surgery
|
N/A | |
Terminated |
NCT03685591 -
PF-06952229 Treatment in Adult Patients With Advanced Solid Tumors
|
Phase 1 | |
Terminated |
NCT01744054 -
Microsphere Localization Using PET/MRI or PET/CT in Patients Following Radioembolization
|
Phase 1 | |
Active, not recruiting |
NCT02969096 -
Clinical Study of Targeted Cryoablation Therapy in the Treatment of Hepatic Carcinoma
|
Phase 2 | |
Recruiting |
NCT01214343 -
Comparing Efficacy of Sorafenib Versus Sorafenib in Combination With Low-dose FP in Patients With Advanced HCC
|
Phase 3 |