Clinical Trial Summary

The investigators are trying to evaluate the agreement of cardiac output measurements taken using the specific thermistor-tipped arterial catheter ( the VolumeView ™ catheter) and the EV1000 ™ monitoring platform ( Edward lifesciences, Irvine, CA, USA) with measurements taken using continuous pulmonary artery thermodilution cardiac output monitoring during orthotopic liver transplantation.


Clinical Trial Description

In cirrhotic patient undergoing liver transplantation, there are an altered patterm of circulation, which is characterized by increased cardiac output, decreased peripheral vascular resistance, and reduced ventricular response to physiological, pharmacological, and surgical stress. Large blood loss and clamping/declamping of the inferior vena cava and portal vein during liver transplantation surgery can affect intravascular volume status, which in turn can lead to hemodynamic instability. Therefore, reliable cardiac output monitoring is particularly useful in the cirrhotic patient undergoing liver transplant. Pulmonary artery thermodilution has been used as a standard method for cardiac output assessment for many years. Pulmonary artery catheter can cause rare but serious complications. And it has some limitations for continuously monitoring cardiac output during rapid hemodynamic changes.

Recently, several minimally invasive CO monitors have been developed. The pulse contour technique continuously estimates CO through mathematical analysis of the waveform of arterial pressure. However, previous studies evaluating the reliability of the pulse contour techniques indicated conflicting results in cirrhotic patients during liver transplantation. Most of studies were performed by analyzing from radial artery pressure waveform. Because of rapid changing of intravascular volume, using inotropics, the monitoring of femoral artery pressure has been recommended during liver transplantation.

A new pulse wave analysis system has developed and introduced into clinical practice that consists of a specific thermistor -tipped femoral arterial catheter ( the VolumeView™ catheter) and the EV1000™ monitoring platform ( Edward lifesciences, Irvine, CA, USA). To continuously assess CO based on the femoral arterial pressure curve signal and it uses transpulmonary thermodilution for calibration. We are trying to evaluate the agreement of cardiac output measurements taken using EV1000™ / VolumeView™ with measurements taken using continuous pulmonary artery thermodilution cardiac output monitoring during orthotopic liver transplantation. ;


Study Design

Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label


Related Conditions & MeSH terms


NCT number NCT02306018
Study type Interventional
Source Samsung Medical Center
Contact
Status Completed
Phase N/A
Start date October 2014
Completion date September 2015

See also
  Status Clinical Trial Phase
Completed NCT02798861 - Controlled Attenuation Parameter (CAP) in Liver Allografts
Completed NCT01968395 - Pharmacokinetics of Caspofungin After One Dose in Patients With Liver Failure Phase 4
Completed NCT01437969 - Pharmacogenomics Study on IL28B Genetic Variants in Italian Patients With HCV Infection naïve to Treatment.
Recruiting NCT00155376 - Intravenous-Morphine and Glucagon-Usage Enhanced MR Cholangiography Phase 4
Recruiting NCT00172705 - Quantitative Diagnosis of Fatty Liver by Dual Energy CT Technique N/A
Completed NCT04185454 - Estimation of Minimum Efficacy Daily Dose of Jarlsberg Cheese N/A
Completed NCT02506335 - Liver Function Measured by HepQuant-SHUNT in the Prediction of Outcomes in Patients With Heart Disease Early Phase 1
Completed NCT02520609 - Dynamic Post-Prandial Metabolism in Patients With Non-Alcoholic Fatty Liver Disease
Completed NCT01970904 - Pharmacokinetics, Pharmacodynamics and Safety of DEB025 Plus Ribavirin in Chronic Hepatitis C Genotype 2 and 3 Treatment naïve Patients N/A
Completed NCT01988753 - Non-invasive Biomarkers of Fibrosis in Pediatric Liver Diseases
Terminated NCT00741117 - Conjugated Hyperbilirubinemia and Pulse Oximetry N/A
Enrolling by invitation NCT01483248 - Human Menstrual Blood-derived Mesenchymal Stem Cells for Patients With Liver Cirrhosis Phase 1/Phase 2
Completed NCT00074386 - Kidney and Liver Transplantation in People With HIV N/A
Completed NCT00245830 - Ischemic Preconditioning of Liver in Cadaver Donors N/A
Completed NCT02329821 - Change of Lactate Concentration During Hartmann Solution Infusion for Hepatic Resection N/A
Completed NCT01650181 - Effects of Siliphos-Selenium-Methionine-Alpha Lipoic Acid in Patients With Fatty Liver and Non-alcoholic Steatohepatitis Phase 4
Completed NCT01303549 - Anidulafungin vs Amphotericin B Safety in High Risk Hepatic Transplant Recipients Phase 4
Completed NCT00799851 - A Randomized Controlled Trial Comparing Band Ligation and Cyanoacrylate Injection for Esophageal Varices Phase 4
Completed NCT00058890 - Gabapentin to Treat Itch in Patients With Liver Disease Phase 3
Completed NCT02311348 - Comparing Pain in Patients Undergoing Percutaneous Versus Transjugular Techniques of Liver Biopsy N/A