Left Ventricular Dysfunction Clinical Trial
Official title:
The Effect of Cardiac Pacing Leads on Tricuspid Regurgitation
The effect of cardiac pacing leads on tricuspid regurgitation is unclear. This study will determine whether using a smaller diameter leads and an alternate position in the ventricle, the proximal septum, will reduce tricuspid regurgitation than larger leads placed in the apex.
Leads are commonly placed in the right ventricular apex. It is not known whether placing
similar leads higher on the septum where there will be less redundancy or pressure on the
septal leaflet will change the extent and severity of tricuspid regurgitation following
pacemaker/ICD implantation. Data has shown that right ventricular pacing can give rise to
right ventricular dysfunction, which in turn may give rise to enlargement of the right
ventricle and cause tricuspid regurgitation.
The study will answer the clinically relevant questions on device lead-related tricuspid
regurgitation.
This study is a single center prospective study at the Mayo Clinic, Rochester. The study
will enroll 200 eligible subjects and follow for 12 months. 50 pacemaker subjects will be
randomized to right ventricular apex pacing 50 pacemaker subjects will be randomized to
right ventricular septum pacing 50 pacemaker subjects will be randomized to left ventricular
pacing via coronary sinus 50 ICD subjects will be enrolled with right ventricular apex
pacing.
A baseline heart failure assessment and Two Dimensional echocardiography will be performed
before device implant.
A Two Dimensional echo will be performed 24 hours after device implant. If significance TR
is present a Three Dimensional echo will be performed. At 12 months post implant heart
failure assessment and Two Dimensional echo will be performed.
;
Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Prevention
Status | Clinical Trial | Phase | |
---|---|---|---|
Enrolling by invitation |
NCT05529654 -
IMpella-Protected cArdiaC Surgery Trial (IMPACT)
|
N/A | |
Recruiting |
NCT04671966 -
Sex Differences in Myocardial Steatosis Induced Left Ventricular Dysfunction
|
Phase 4 | |
Not yet recruiting |
NCT05188222 -
Preoperative Maltodextrin's Effect on Cardiac Function in Cardiac Surgery
|
Phase 4 | |
Recruiting |
NCT04950218 -
The Psoriasis Echo Study
|
||
Completed |
NCT01076920 -
Mesenchymal Stem Cells and Myocardial Ischemia
|
Phase 1/Phase 2 | |
Completed |
NCT01128790 -
Pilot Study of Remote Ischemic Preconditioning in Heart Failure
|
N/A | |
Completed |
NCT04942353 -
Effects of Home-based Exercise Rehabilitation on Healthcare Utilization in HeartMate 3 Patients
|
N/A | |
Recruiting |
NCT05769036 -
Conventional Biventricular Versus Left Bundle Branch Pacing on Outcomes in Heart Failure Patients
|
N/A | |
Completed |
NCT03232736 -
InterventiOn of Biventricular Pacemaker Function on ventrIcular Function Among Patients With LVAD's
|
||
Recruiting |
NCT04694092 -
Landiolol for Rate Control in Decompensated Heart Failure Due to Atrial Fibrillation
|
N/A | |
Completed |
NCT02013037 -
The De-novo Use of Eculizumab in Presensitized Patients Receiving Cardiac Transplantation
|
Phase 3 | |
Completed |
NCT01609738 -
Left Ventricular Septum Pacing in Patients by Transvenous Approach Through the Inter-ventricular Septum
|
Phase 1/Phase 2 | |
Completed |
NCT00551681 -
Effects of Left Ventricular Pacing Optimilization on Cardiac Perfusion, Contractile Force, and Clinical Performance in Patients With Ventricular Dysfunction and Heart Failure
|
N/A | |
Not yet recruiting |
NCT04103008 -
Left Ventricular Function After Primary Percutaneous Coronary Intervention: Role of Speckle Echocardiography
|
||
Completed |
NCT06197256 -
Cardiac Dysfunction in Critically Ill Covid-19 Patients
|
||
Recruiting |
NCT05860504 -
Acute Cardiac Dysfunction in Critical Illnes
|
||
Completed |
NCT03787810 -
Left Ventricular Dysfunction in Critically Ill Patients
|
||
Active, not recruiting |
NCT00461734 -
PROTECT-PACE STUDY - The Protection of Left Ventricular Function During Right Ventricular Pacing
|
N/A | |
Recruiting |
NCT04752293 -
Pediatric Hypertension and the Renin-Angiotensin SystEm (PHRASE)
|
||
Not yet recruiting |
NCT05760924 -
Left Bundle Branch Pacing on Outcomes and Ventricular Remodeling in Biventricular CRT Nonresponders
|
N/A |