Airway Management Clinical Trial
Official title:
Randomised Crossover Comparison of the Ambu AuraGain and the iGel in Anaesthetised Adults
This study will look at key performance indicators of 2 supraglottic airway devices in anaesthetised adults in a crossover manner.
A supraglottic airway device (SAD), also referred to as laryngeal mask airway (LMA), is a
medical device that maintains a patients airway, allowing unobstructed ventilation during
anaesthesia. They are designed to sit in the patient's hypopharynx (throat), with their
elliptical head forming a seal around the supraglottic structures (the patients "voice box").
They have been in common use since 1989, transforming anaesthetic practice and are now the
predominant airway device within anaesthesia, being used in approximately 56% of all general
anaesthetic cases in the UK(1). Their popularity for routine use stems from its perceived
benefits over traditional forms of airway management coupled with their high overall success
rate and low complication rate.
SADs, in anaesthetic practice, are inserted after induction of general anaesthesia, by or
under supervision of, a trained medical professional. All patients are fully monitored as set
out by the Association of Anaesthetist of Great Britain and Ireland; Recommendations for
standards of monitoring during anaesthesia and recovery (2). Devices are used in concordance
with manufacturer instruction. Successful first time placement is achieved in a large
majority of patients and allows provision of oxygen and ventilation. In some patients, one
device or size of device may present sub-optimal performance resulting in the removal of the
device. Further actions in this scenario would include attempting a second insertion of the
same device, attempting an insertion with an alternative size of the same device or a further
attempt with an alterative design of device in order to achieve a patent airway. Further
attempts may be taken but should be limited to avoid unnecessary trauma. In some cases the
use of the SAD is abandoned and the patient is intubated with an endotracheal tube in order
to provide a safe secure airway.
Alternatives to use of a SAD for airway management include use of a simple facemask or
tracheal intubation with an endotracheal tube. Advantages of using a SAD for anaesthetic
airway management compared to a facemask are improved oxygen saturation and less
operator/anaesthetist fatigue. Compared to an endotracheal tube the advantages of using a SAD
are improved haemodynamic stability at induction and emergence from anaesthesia, reduced
anaesthetic requirements, improved quality of emergence, lower incidence of sore throat,
increased ease of placement and reduced risk of dental damage. Risks of using an LMA compared
to an endotracheal tube are increased gastric insufflation and aspiration with these being
more common in patients who are poorly selected for anaesthesia with a SAD. Sore throat is
the most common complication with a study
There have been significant developments in design in the SAD market in recent years with
development of a "second generation" range of devices involving new materials and designs
that integrate protective bite blocks, gastric drainage channels and improved supraglottic
seal enhancing patient safety when using these devices. There are now some new "third
generation" SADs on the market with designs that may enhance anaesthetic practice and improve
patient safety further.
This study will follow similar ethically approved protocols used in published studies
comparing airway equipment (3,4). These are only 2 examples but there are hundreds of LMA
studies throughout the literature. The Ambu AuraGain is a new device and has not been studied
fully. Comparative studies frequently assess oropharyngeal leak pressure (OLP), a fibre optic
assessment of glottic alignment, ease of insertion, ability to insert a nasogastric tube down
the gastric port and frequency of manipulations.
We propose a crossover design to better detect differences between the two devices as this
eliminates confounding differences in patient characteristics and demographics.
There have been significant developments in design in the SAD market in recent years with
Our proposal would be to carry out a randomised crossover comparison between a new "third
generation" SAD; the AuraGainTM (Ambu, Copenhagen, Denmark) and our current "second
generation" SAD; the i-gel (Intersurgical Ltd, Wokingham, UK) to examine and compare key
performance indicators with their use.
The AuraGain is a new device on the market and has not been compared to other devices yet.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03908411 -
The Effect of Paratracheal Pressure on the Glottic View
|
N/A | |
Completed |
NCT04564105 -
Simulation Training and Teamwork Concerning Intubation on the Icu
|
N/A | |
Completed |
NCT02988336 -
TMHT - New Method of Difficult Intubation Prediction
|
N/A | |
Completed |
NCT03002857 -
Comparison of I-gel LMA, Classical LMA With a New Supraglottic Airway the Baska Mask® in Urological Surgery
|
N/A | |
Recruiting |
NCT06337006 -
Laryngeal Mask Airway Failure in Pediatric Patients
|
||
Completed |
NCT03443219 -
RCT- LMA Supremeā¢ Versus the Spritztube® Tracheal Cannula in Anesthetized Adult Patients
|
N/A | |
Completed |
NCT05044416 -
VieScope in Patients With an Expected Difficult Airway
|
N/A | |
Not yet recruiting |
NCT05534451 -
Comparison Among Three Different Video Scope Guided Nasotracheal Intubation.
|
N/A | |
Recruiting |
NCT06073977 -
Risk Factors for Pediatric Difficult Supraglottic Airway Placement and Ventilation
|
||
Not yet recruiting |
NCT03687385 -
The Effect of High-flow Nasal Oxygenation to the Saturation During Analgo-sedation in Different ASA Risk Class Patients
|
N/A | |
Not yet recruiting |
NCT03687424 -
Can High-flow Nasal Oxygenation Improve Oxygen Saturation During Analgo-sedation in Obese Adults?
|
N/A | |
Enrolling by invitation |
NCT05055401 -
Airway Management Skills Amongst Anesthesia Providers
|
||
Not yet recruiting |
NCT02920879 -
Airway Effects of PEEP During Anesthesia Induction.
|
N/A | |
Completed |
NCT02263300 -
Spatial Orientation and Fiberoptic Intubation Skills in the Novice: A Randomized Controlled Trial
|
||
Completed |
NCT01718561 -
The Difficult Airway Management Trial: "The DIFFICAIR-Trial"
|
N/A | |
Completed |
NCT01635660 -
Out-of-Hospital Randomized Comparison of Video-assisted Endotracheal Intubation
|
N/A | |
Completed |
NCT00956592 -
Clinical Evaluation of the Storz CMAC Laryngoscope
|
N/A | |
Completed |
NCT00892671 -
Airway Management and Vascular Access Simulation
|
N/A | |
Completed |
NCT03848559 -
Airway Management With Simulated Microgravity Using a Submerged Model
|
N/A | |
Completed |
NCT05160207 -
Intubation-induced Decrease in Heart Rate as an Indicator for Intraoperative Bradycardia
|