Clinical Trials Logo

Clinical Trial Summary

The primary objective of our study is to use a biased coin up-down allocation methodology to estimate the dose of bupivacaine required after the lidocaine test dose to achieve initial effective comfort in 90% of patients (post test-dose ED90) via the epidural (DPE or EPL) technique in women undergoing labor induction or augmentation; we hypothesize that we will be able to determine the post test-dose ED90 of bupivacaine for each technique with adequate precision to inform the optimal doses to study in a subsequent randomized trial comparing the analgesic effects of DPE vs. EPL. We also hypothesize that the post test-dose ED90 of bupivacaine is lower with a DPE technique than with a conventional epidural technique.


Clinical Trial Description

We will be conducting a randomized controlled trial with patients randomized into either an EPL or a DPE group. For the first subject in the DPE and EPL techniques, the initial dose of bupivacaine 25 mg will be used, with an endpoint being the achievement of an NRS < 3 at 30 min. Subsequent patients are administered bupivacaine doses determined by the response of the previous subject, as per the biased coin method. The subsequent up and down interval doses are bupivacaine 2.5 mg (1 mL) increments. Hence, if the first subject does not respond successfully, the dose for the second subject will be bupivacaine 27.5 mg. If the second subject does not respond successfully, the dose for the third subject will be bupivacaine 30 mg. By contrast, if a subject responds successfully, the bupivacaine dose will be decreased to 22.5 mg with a probability of 10% and maintained with a probability of 90% (ratio 1:9). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06146842
Study type Interventional
Source Brigham and Women's Hospital
Contact Lawrence Tsen, MD
Phone 617-732-8216
Email ltsen@bwh.harvard.edu
Status Not yet recruiting
Phase N/A
Start date December 1, 2023
Completion date December 31, 2025

See also
  Status Clinical Trial Phase
Completed NCT03539562 - Therapeutic Rest to Delay Admission in Early Labor: A Prospective Study on Morphine Sleep
Withdrawn NCT04662450 - Evaluation and Management of Parturients' Pain Intensity N/A
Completed NCT02885350 - Spinal or Epidural Fentanyl or Sufentanil for Labour Pain in Early Phase of the Labour Phase 4
Completed NCT02550262 - Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor N/A
Completed NCT01598506 - Intrathecal Hydromorphone for Labor Analgesia Phase 2
Withdrawn NCT01636999 - Comparing Sedara to Butorphanol in Early Labor N/A
Completed NCT00987441 - Epidural Labor Analgesia and Infant Neurobehavior N/A
Completed NCT00755092 - Effect of Doula in Nulliparas and Multiparas N/A
Terminated NCT00787176 - The Association Between Fluid Administration, Oxytocin Administration, and Fetal Heart Rate Changes N/A
Recruiting NCT06036797 - Efficacy and Safety of Hydromorphone-ropivacaine Versus Sufentanil-ropivacaine for Epidural Labor Analgesia Phase 2
Completed NCT05512065 - Changes in Velocimetric Indices of Uterine and Umbilical Arteries Before and After Combined Spinal-epidural Analgesia in Laboring Women N/A
Completed NCT05327088 - Epidural Dexmedetomidine vs Nalbuphine for Labor Analgesia Phase 2
Completed NCT03103100 - Comparing Bupivacaine, Lidocaine, and a Combination of Bupivacaine and Lidocaine for Labor Epidural Activation Phase 3
Recruiting NCT03623256 - Comparison of Intrathecal Versus Epidural Fentanyl on Fetal Bradycardia in Labor Combined Spinal Epidural Analgesia Phase 4
Active, not recruiting NCT02271100 - Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique N/A
Completed NCT02926469 - Virtual Reality Analgesia in Labor: The VRAIL Pilot Study N/A
Completed NCT03712735 - Programmed Intermittent Epidural Bolus For Laboring Obstetrical Women Phase 4
Not yet recruiting NCT05565274 - Outcome of Combined Tramadol and Paracetamol Versus Pentazocine as Labour Analgesia Among Parturients N/A
Recruiting NCT02575677 - Oxycodone in Treatment of Early Labour Pain Efficacy and Safety
Recruiting NCT01708668 - The Effects of Intermittent Epidural Bolus on Fever During Labor Analgesia N/A