Labor Pain Clinical Trial
Official title:
A Trial to Determine the Optimal Bupivacaine Dose for Initiation of Labor Epidural Pain Relief With a Lidocaine Test Dose
The primary objective of our study is to use a biased coin up-down allocation methodology to estimate the dose of bupivacaine required after the lidocaine test dose to achieve initial effective comfort in 90% of patients (post test-dose ED90) via the epidural (DPE or EPL) technique in women undergoing labor induction or augmentation; we hypothesize that we will be able to determine the post test-dose ED90 of bupivacaine for each technique with adequate precision to inform the optimal doses to study in a subsequent randomized trial comparing the analgesic effects of DPE vs. EPL. We also hypothesize that the post test-dose ED90 of bupivacaine is lower with a DPE technique than with a conventional epidural technique.
We will be conducting a randomized controlled trial with patients randomized into either an EPL or a DPE group. For the first subject in the DPE and EPL techniques, the initial dose of bupivacaine 25 mg will be used, with an endpoint being the achievement of an NRS < 3 at 30 min. Subsequent patients are administered bupivacaine doses determined by the response of the previous subject, as per the biased coin method. The subsequent up and down interval doses are bupivacaine 2.5 mg (1 mL) increments. Hence, if the first subject does not respond successfully, the dose for the second subject will be bupivacaine 27.5 mg. If the second subject does not respond successfully, the dose for the third subject will be bupivacaine 30 mg. By contrast, if a subject responds successfully, the bupivacaine dose will be decreased to 22.5 mg with a probability of 10% and maintained with a probability of 90% (ratio 1:9). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03539562 -
Therapeutic Rest to Delay Admission in Early Labor: A Prospective Study on Morphine Sleep
|
||
Withdrawn |
NCT04662450 -
Evaluation and Management of Parturients' Pain Intensity
|
N/A | |
Completed |
NCT02885350 -
Spinal or Epidural Fentanyl or Sufentanil for Labour Pain in Early Phase of the Labour
|
Phase 4 | |
Completed |
NCT02550262 -
Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor
|
N/A | |
Completed |
NCT01598506 -
Intrathecal Hydromorphone for Labor Analgesia
|
Phase 2 | |
Withdrawn |
NCT01636999 -
Comparing Sedara to Butorphanol in Early Labor
|
N/A | |
Completed |
NCT00987441 -
Epidural Labor Analgesia and Infant Neurobehavior
|
N/A | |
Completed |
NCT00755092 -
Effect of Doula in Nulliparas and Multiparas
|
N/A | |
Terminated |
NCT00787176 -
The Association Between Fluid Administration, Oxytocin Administration, and Fetal Heart Rate Changes
|
N/A | |
Recruiting |
NCT06036797 -
Efficacy and Safety of Hydromorphone-ropivacaine Versus Sufentanil-ropivacaine for Epidural Labor Analgesia
|
Phase 2 | |
Completed |
NCT05512065 -
Changes in Velocimetric Indices of Uterine and Umbilical Arteries Before and After Combined Spinal-epidural Analgesia in Laboring Women
|
N/A | |
Completed |
NCT05327088 -
Epidural Dexmedetomidine vs Nalbuphine for Labor Analgesia
|
Phase 2 | |
Completed |
NCT03103100 -
Comparing Bupivacaine, Lidocaine, and a Combination of Bupivacaine and Lidocaine for Labor Epidural Activation
|
Phase 3 | |
Recruiting |
NCT03623256 -
Comparison of Intrathecal Versus Epidural Fentanyl on Fetal Bradycardia in Labor Combined Spinal Epidural Analgesia
|
Phase 4 | |
Active, not recruiting |
NCT02271100 -
Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique
|
N/A | |
Completed |
NCT02926469 -
Virtual Reality Analgesia in Labor: The VRAIL Pilot Study
|
N/A | |
Completed |
NCT03712735 -
Programmed Intermittent Epidural Bolus For Laboring Obstetrical Women
|
Phase 4 | |
Not yet recruiting |
NCT05565274 -
Outcome of Combined Tramadol and Paracetamol Versus Pentazocine as Labour Analgesia Among Parturients
|
N/A | |
Recruiting |
NCT02575677 -
Oxycodone in Treatment of Early Labour Pain Efficacy and Safety
|
||
Recruiting |
NCT01708668 -
The Effects of Intermittent Epidural Bolus on Fever During Labor Analgesia
|
N/A |