Labor Pain Clinical Trial
Official title:
Optimum Length of Catheter in the Epidural Space for Labor Analgesia in Non-obese Women: a Randomised Controlled Trial of 4 cm Versus 5 cm
Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space. Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm. Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space. This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection. The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03539562 -
Therapeutic Rest to Delay Admission in Early Labor: A Prospective Study on Morphine Sleep
|
||
Withdrawn |
NCT04662450 -
Evaluation and Management of Parturients' Pain Intensity
|
N/A | |
Completed |
NCT02885350 -
Spinal or Epidural Fentanyl or Sufentanil for Labour Pain in Early Phase of the Labour
|
Phase 4 | |
Completed |
NCT02550262 -
Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor
|
N/A | |
Completed |
NCT01598506 -
Intrathecal Hydromorphone for Labor Analgesia
|
Phase 2 | |
Withdrawn |
NCT01636999 -
Comparing Sedara to Butorphanol in Early Labor
|
N/A | |
Completed |
NCT00987441 -
Epidural Labor Analgesia and Infant Neurobehavior
|
N/A | |
Completed |
NCT00755092 -
Effect of Doula in Nulliparas and Multiparas
|
N/A | |
Terminated |
NCT00787176 -
The Association Between Fluid Administration, Oxytocin Administration, and Fetal Heart Rate Changes
|
N/A | |
Recruiting |
NCT06036797 -
Efficacy and Safety of Hydromorphone-ropivacaine Versus Sufentanil-ropivacaine for Epidural Labor Analgesia
|
Phase 2 | |
Completed |
NCT05512065 -
Changes in Velocimetric Indices of Uterine and Umbilical Arteries Before and After Combined Spinal-epidural Analgesia in Laboring Women
|
N/A | |
Completed |
NCT05327088 -
Epidural Dexmedetomidine vs Nalbuphine for Labor Analgesia
|
Phase 2 | |
Completed |
NCT03103100 -
Comparing Bupivacaine, Lidocaine, and a Combination of Bupivacaine and Lidocaine for Labor Epidural Activation
|
Phase 3 | |
Recruiting |
NCT03623256 -
Comparison of Intrathecal Versus Epidural Fentanyl on Fetal Bradycardia in Labor Combined Spinal Epidural Analgesia
|
Phase 4 | |
Active, not recruiting |
NCT02271100 -
Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique
|
N/A | |
Completed |
NCT02926469 -
Virtual Reality Analgesia in Labor: The VRAIL Pilot Study
|
N/A | |
Completed |
NCT03712735 -
Programmed Intermittent Epidural Bolus For Laboring Obstetrical Women
|
Phase 4 | |
Not yet recruiting |
NCT05565274 -
Outcome of Combined Tramadol and Paracetamol Versus Pentazocine as Labour Analgesia Among Parturients
|
N/A | |
Recruiting |
NCT01708668 -
The Effects of Intermittent Epidural Bolus on Fever During Labor Analgesia
|
N/A | |
Recruiting |
NCT02575677 -
Oxycodone in Treatment of Early Labour Pain Efficacy and Safety
|