Clinical Trials Logo

Clinical Trial Summary

This multicenter, non-comparative clinical trial, led by two principal investigators in Spain, aims to evaluate the safety and performance of a robotic assistant, based on a electromechanical tracking system, in patients requiring transpedicular screw fixation. The study, conducted in two different hospital centers, involves patients with vertebral fractures, spinal stenosis, kyphosis, and other related conditions. The primary objective is to determine screw accuracy by assessing the degree of screw invasion into the pedicle using the Gertzbein-Robbins scale, with a target of achieving 96% acceptable screw placement. Trained radiologists will evaluate the screw invasion into the pedicle. The study is scheduled to span 12 months and each intervention includes a 1-month follow-up. Throughout this time frame, patients will undergo regular assessments, and outcomes will be closely monitored.


Clinical Trial Description

Multicenter non-comparative clinical trial. This interventional study aims to assess the safety and performance of a robotic assistant, based on a electromechanical tracking system, in patients requiring transpedicular screw fixation.The primary focus is on overcoming the limitations of traditional minimally invasive surgeries and enhancing the accuracy of pedicle screw placement, especially within the complex pedicle region adjacent to the spinal canal. The study design is a prospective interventional trial conducted in two hospital centers in Spain, with two principal investigators leading the investigation. Patients requiring transpedicular screw fixation will be recruited. The robotic assistant will be employed to facilitate transpedicular screw fixation. The system aims to improve accuracy and safety in screw placement, in comparison with conventional techniques used. Patients will include individuals with spinal fractures, spinal stenosis, kyphosis, and other conditions requiring transpedicular screw fixation. Two principal investigators in Spain will lead the recruitment process. The study aims to answer several key questions: - Determine Screw Accuracy: Assess the degree of screw invasion into the pedicle using the Gertzbein-Robbins scale, with a target of achieving 96% acceptable screw placement. - Evaluate Planning vs. Final Screw Placement: Determine the accuracy of screw placement by comparing planned positions with the actual final positions. - System Performance: Assess the overall performance of the robotic system during the surgical procedure. - Reoperation and Postoperative Time: Determine the need for reoperation and evaluate postoperative recovery time. - Adverse Events: Detect and document any adverse events occurring during the surgical process. Trained radiologists will play a crucial role in evaluating the accuracy of screw placement, focusing on the degree of invasion into the pedicle using the Gertzbein-Robbins scale. The study is set to span a duration of 12 months,during which patients will undergo regular assessments, and outcomes will be closely monitored. The inclusion of the electromechanical tracking system in the robotic assistant adds a technological dimension to the investigation, contributing to advancements in the field of minimally invasive spinal surgeries. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06153511
Study type Interventional
Source Cyber Surgery S.L.
Contact
Status Completed
Phase N/A
Start date November 16, 2022
Completion date July 7, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT04795284 - Biomechanical Parameters of Gait in Patients With Symptomatic Lumbar Spinal Stenosis and Healthy Elderly.
Recruiting NCT04066296 - Outcomes for Lumbar Decompressions With Use of Liposomal Bupivicaine Phase 2
Active, not recruiting NCT05114135 - TLIF Osteo3 ZP Putty Study (Also Known as the TOP Fusion Study) N/A
Recruiting NCT06075862 - Balance Amongst Patients With Lumbar Spinal Stenosis
Recruiting NCT06057428 - Activity Levels Amongst Patients With Lumbar Spinal Stenosis
Recruiting NCT05527145 - Spinal Stenosis and Listhesis Treated With Percutaneous Interspinous Spacer: a Non-surgical Trial N/A
Recruiting NCT01902979 - The Spinal Stenosis Pedometer and Nutrition e-Health Lifestyle Intervention (SSPANLI) Trial N/A
Completed NCT00749073 - The Vertos MILD™ Preliminary Patient Evaluation Study N/A
Completed NCT00527527 - Chiropractic Dosage for Lumbar Stenosis Phase 2
Completed NCT00405691 - Safety and Effectiveness Study of the TOPS System, a Total Posterior Arthroplasty Implant Designed to Alleviate Pain Resulting From Moderate to Severe Lumbar Stenosis Phase 3
Completed NCT03194607 - Quantitative Evaluation of Motor Function Before and After Surgery for Degenerative Lumbar Spinal Stenosis
Recruiting NCT06034405 - Analysis of Lumbar Spine Stenosis Specimens for Identification of Transthyretin Cardiac Amyloidosis
Completed NCT06079580 - Patients With Lumbar Spinal Stenosis With Balance Disorder
Recruiting NCT05523388 - Role of Spinal Load in the Pathophysiology of Lumbar Spinal Stenosis
Completed NCT04587401 - The Effects of Anesthesia on Cerebral Perfusion in Patients With High Blood Pressure N/A
Completed NCT04563793 - Postmarket Outcomes Study for Evaluation of the Superion™ Spacer
Suspended NCT03381677 - Pedicle Osteotomy for Stenosis Trial N/A
Completed NCT02258672 - Preoperative Rehabilitation for Patients Undergoing Surgery for Lumbar Spinal Stenosis N/A
Completed NCT02260401 - Long Term Outcomes of Lumbar Epidural Steroid Injections for Spinal Stenosis N/A
Completed NCT01994512 - Swedish Spinal Stenosis Study N/A