Clinical Trials Logo

Clinical Trial Details — Status: Active, not recruiting

Administrative data

NCT number NCT01912417
Other study ID # 01
Secondary ID
Status Active, not recruiting
Phase N/A
First received July 26, 2013
Last updated September 4, 2013
Start date August 2010
Est. completion date January 2014

Study information

Verified date September 2013
Source Universidade Católica de Pelotas
Contact n/a
Is FDA regulated No
Health authority Brazil: National Committee of Ethics in Research
Study type Interventional

Clinical Trial Summary

The aim of this study is to evaluate the effect of aerobic exercise during dialysis on the hemodialysis efficacy in the removal of small molecules measured by continues spend sampling of dialysate (liquid metabolites produced by the body which is disposed) technique.


Description:

This is a controlled clinical trial with participants recruited from the dialysis unit of a university hospital (a tertiary-care centre). All patients from this unit who agreed and that had no medical contraindications had already been included in a resistance and aerobic intradialytic training program. In this unit, the size of the low flux polysulfone dialyzers is selected according to patient's body surface area and the dialyzers are reused up to twelve times. The target Kt/V is 1.2 or higher. The target hemoglobin level is from 10.5 to 12.5 g/dL. Dialysis is performed using On-Line Clearance Monitor (OCM)-equipped Fresenius 4008-S machines (Fresenius, Bad Homburg, Germany).

Design: Patients are included in a randomly crossover study design such that each patient receives one HD session with exercise (intervention) and the next session without exercise (control), alternating for six consecutive HD sessions. The blood flow is maintained at around 300mL/minute and the dialysate flow at 500mL/minute. The dialysate calcium concentration used is 3.0 mEq/L. A new dialyzer is used in the first HD session of each patient at the study, and the dialyzer is reprocessed and reused up to 12 times according to its priming in subsequent sessions. During every HD session continuous spent sampling of dialysate is obtained. The study began in August 2010.

Interventions - Participants underwent hemodialysis sitting in a reclining chair. They trained on an Equimond© mechanically braked cycle ergometer, which we positioned and stabilized in front of the participants while they sit in their chairs during hemodialysis. The training is performed in the first 2 hours of hemodialysis, with a total exercise time of 60 minutes. Each exercise period of 20 minutes is separated by 10 minutes of rest. The patients are advised to work with a level of perceived exertion of 'somewhat strong' (13-14 of Borg scale). For safety, heart rate and blood pressure is monitored throughout the session. The training is terminated if the patients exceeded 80% of their maximum heart rate (MHR = 220 - age in years), blood pressure parameters are exceeded (above 200/110 or below 110/50mmHg) or the patient had chest pain, severe dyspnea, wheezing, leg cramps, confusion, visual symptoms, pallor or cyanosis. Training is conducted by physiotherapists.

Data Collection - Age, gender, skin color, time since starting dialysis therapy and co-morbidity are recorded at baseline. Each patient's hemoglobin level, hematocrit, blood pressure, body mass index (kg/m2) are noted at the beginning and end of the study period. Serum concentration of urea, creatinine, potassium and phosphate are obtained before, after, and 30 minutes after each HD session. The dialysate concentration of urea, creatinine, potassium and phosphate and Kt/V estimated by OCM were obtained during each HD session. The laboratory analyses are conducted by a technician blinded to allocation groups. The OCM measures the difference in conductivity between the dialysate that is coming in and out of the dialyzer and gives an estimated value of Kt/V.


Recruitment information / eligibility

Status Active, not recruiting
Enrollment 28
Est. completion date January 2014
Est. primary completion date February 2012
Accepts healthy volunteers No
Gender Both
Age group 15 Years to 90 Years
Eligibility Inclusion Criteria:

The participants of the study were chronic kidney disease patients on hemodialysis for more than 3 months, with a thrice-weekly, for 4 hours and using arteriovenous fistula. The inclusion criteria were residual diuresis less than 500 mL/day; hemodynamic stability during HD treatment (hypotension episodes in <15% of the sessions); good vascular access allowing a blood flow rate greater than 250 mL/min; a hemoglobin level greater than 9.0 g/dL, able to keep sitting and standing balance and walk without assistance, and to be already participating in the exercise program during dialysis.

Exclusion Criteria:

Exclusion criteria were the use of catheter as venous access, symptomatic ischemic heart disease, myocardial infarction less than 6 months, uncontrolled hypertension, pleural or pericardial friction rub, aortic stenosis.

Study Design

Allocation: Randomized, Intervention Model: Crossover Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Other:
Aerobic exercise with cycle ergometer during hemodialysis
Participants underwent hemodialysis trained on an cycle ergometer. The training is performed in the first 2 hours of hemodialysis, with a total exercise time of 60 minutes. Each exercise period of 20 minutes was separated by 10 minutes of rest. The patients are advised to work with a level of perceived exertion of 'somewhat strong' (13-14 of Borg scale). For safety, heart rate and blood pressure were monitored throughout the session. The training is terminated if the patients exceeded 80% of their maximum heart rate (MHR = 220 - age in years), blood pressure parameters are exceeded (above 200/110 or below 110/50mmHg) or the patient had chest pain, severe dyspnea, wheezing, leg cramps, confusion, visual symptoms, pallor or cyanosis.

Locations

Country Name City State
Brazil Hospital São Francisco de Paula Pelotas Rio Grande do Sul

Sponsors (1)

Lead Sponsor Collaborator
Universidade Católica de Pelotas

Country where clinical trial is conducted

Brazil, 

Outcome

Type Measure Description Time frame Safety issue
Primary The main outcome was the dialysate concentrations of urea, creatinine, potassium and phosphate. The dialysate is collected by continuous spent sampling of dialysate (CSSD). For the CSSD technique, spent dialysate was continuously sampled by a reversed automatic infusion pump (Lifemed®) at a rate of 10 mL/hour.
The dialysate concentrations of urea, creatinine, potassium and phosphate are measured in the sample recipient and the total masses removed are calculated by multiplying the dialysate concentration by the estimated total dialysate volume.
three months Yes
See also
  Status Clinical Trial Phase
Completed NCT03246984 - VALUE- Vascular Access Laminate eUropean Experience. A Post Market Surveillance Study to Assess the Safety and Effectiveness of VasQ N/A
Completed NCT02922361 - Spending and Outcomes for Complex Medicare Advantage Patients
Completed NCT02235571 - iChoose Decision Kidney Aid for End-Stage Renal Disease Patients N/A
Completed NCT01933789 - Improving Communication About Serious Illness N/A
Completed NCT01922843 - A Phase 2 Study of an Oral Vitamin D Compound (DP001) in Secondary Hyperparathyroidism in Patients on Hemodialysis Phase 2
Completed NCT01930396 - Use of Tinzaparin for Anticoagulation in Hemodialysis Phase 4
Not yet recruiting NCT01674660 - Factors Associated With Interdialytic Blood Pressure Variability in Maintenance Hemodialysis Patients N/A
Not yet recruiting NCT01157260 - The Effects of AST-120 on Endothelial Dysfunction in Patients With Chronic Kidney Disease Phase 4
Completed NCT01209403 - Insulin-like Growth Factor (IGF-I) in Hemodialysis Patients Phase 4
Completed NCT00753116 - Renal Denervation in End Stage Renal Disease Patients With Refractory Hypertension Phase 1
Recruiting NCT00532688 - N-Acetylcysteine in Heart Failure With Coexistent Chronic Renal Failure Phase 2/Phase 3
Completed NCT00534144 - Comparison Between Effects of Two Iron Preparations on Protein in the Urine Phase 1
Completed NCT00528788 - How Vitamin D Analogues Affect Endothelial Cells in Patients on Dialysis Phase 4
Completed NCT00226902 - Vascular Reactivity in Kidney Disease Patients N/A
Completed NCT00382044 - Audit of the Effect of Changing From IV to SC Administration of ESA's in Haemodialysis Patients N/A
Recruiting NCT00235287 - Pulse Wave Velocity, Pulse Wave Morphology and Blocking of the Reninangiotensin System in Patients With Chronic Kidney Disease Phase 4
Completed NCT00224081 - DRIVE Trial (Dialysis Patients' Response to Intravenous [IV] Iron With Elevated Ferritin) Phase 4
Completed NCT00071214 - Study to Evaluate the Effectiveness of StaphVAX in Adults on Hemodialysis Phase 3
Completed NCT00049907 - Cardiac and Renal Disease Study (CARDS) N/A
Completed NCT00006297 - Risk Factors for CV Disease in a Dialysis Cohort N/A