Joint Diseases Clinical Trial
Official title:
Delta Ceramax™ Ceramic-on-Ceramic Acetabular Cup Prosthesis Study (28mm)
The study is designed to evaluate artificial hips with a 28 mm ceramic head and a ceramic liner to determine whether they perform as well as artificial hips with a 28 mm ceramic head and a polyethylene liner.
Total Hip Arthroplasty (THA) is the surgical reconstruction of the hip joint through replacement of the femoral head and the acetabular articulating surfaces with fixed prosthetic devices. The goals of THA are relief from pain, restoration of function, and correction of deformity. THA is one of the most common adult reconstructive procedures. Over the past 25 years, patients who have needed to have their hip joint replaced, either due to trauma or arthritic disease, typically have had their hip joint bone articular surfaces replaced with a metal hip stem, metal ball head (either stainless steel or chrome cobalt) and a plastic acetabular cup (metal/metal/plastic). While the basic device has remained essentially unchanged over that period, technological advancements in implant designs and materials, and improvements in surgical technique and instrumentation have made THA one of the most durable and successful procedures in medicine. Reproducible, high-quality, short-term and mid-term results are attained regularly, and total hip replacements commonly last 10 to 15 years and longer. The success of this procedure has allowed its expansion into a wider, and often younger and more active population. In spite of the improvements in THA, little change has occurred for the acetabular cup liner, which is usually made out of Ultra High Molecular Weight Polyethylene plastic (UHMWPe). Because it is plastic and inherently soft and somewhat pliable under load, the cup's articular surface must inevitability wear and produce debris. This biologic response is now thought to be a significant contributor to prosthetic component loosening, a primary failure mode of THR. UHMWPe also degrades with time in the body. As concerns about polyethylene wear and the associated untoward effects of the generated wear debris, and as THA continues to be used in younger and higher-demand patients with increasing life expectancies, interest in ceramic on ceramic total hip prosthesis has been renewed. An alumina ceramic-on-ceramic acetabular coupling has been employed as an alternative to metal/polyethylene couplings. This ceramic-on-ceramic coupling has many advantages, including the elimination of polyethylene from the device system, wear rates that are appreciably less than those experienced with metal/polyethylene couplings and reduced biologic reactivity. The potential benefits of an alumina ceramic/ceramic bearing are significant. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Withdrawn |
NCT04976972 -
A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation
|
N/A | |
| Not yet recruiting |
NCT03726788 -
Intra Articular Injection of Botulinum Toxin Versus Corticoids in Gonarthrosis
|
Phase 2 | |
| Completed |
NCT02944448 -
A Study Evaluating Pain Relief and Safety of Orally Administered CR845 in Patients With Osteoarthritis of Hip or Knee
|
Phase 2 | |
| Completed |
NCT02604446 -
Depot-opioids for Pre- and Postoperative Pain Relief After Primary Knee Arthroplasty.Tapentadol vs Oxycodone vs Placebo
|
Phase 3 | |
| Completed |
NCT02269254 -
Persona Versus NexGen
|
N/A | |
| Completed |
NCT02256098 -
RSA RCT: ATTUNE™ TKA Versus PFC Sigma TKA
|
N/A | |
| Completed |
NCT00815243 -
Telemedicine Consultation in Trauma and Orthopedic
|
N/A | |
| Recruiting |
NCT05564182 -
High Intensity Laser Therapy in the Treatment of Hemiplegic Shoulder Pain
|
N/A | |
| Recruiting |
NCT06142669 -
EVOLUTION® Revision STEMMED CS Post Market Clinical Follow-up Study Protocol
|
||
| Enrolling by invitation |
NCT04147559 -
Post Market Clinical Follow-Up Study for PROFEMUR® Preserve Classic Femoral Stem
|
||
| Terminated |
NCT02591368 -
MiniTightRope Suspensionplasty Compared With LRTI for the Treatment of Basilar Thumb Arthritis
|
N/A | |
| Completed |
NCT01227694 -
Adult Stem Cell Therapy for Repairing Articular Cartilage in Gonarthrosis
|
Phase 1/Phase 2 | |
| Completed |
NCT00784277 -
A Study to Compare the Frequency of Constipation Symptoms With Tapentadol Immediate Release (IR) Treatment Versus Oxycodone IR Treatment in Patients With End-stage Joint Disease
|
Phase 3 | |
| Active, not recruiting |
NCT05618782 -
Clinical Trial to Evaluate the Efficacy and Safety of LEVI-04 in Patients With Osteoarthritis of the Knee
|
Phase 2 | |
| Recruiting |
NCT04029792 -
Evaluation of a Combination of Plant Extracts (BSL_EP028) on Joint Mobility
|
Phase 1/Phase 2 | |
| Active, not recruiting |
NCT06404346 -
Comparative Effectiveness of HVT and Bowen Technique in Patients of SI Joint Dysfunction With Upslipped Innominates
|
N/A | |
| Terminated |
NCT04712019 -
Evaluating Edema and Range of Motion Using Negative Pressure Therapy vs. Standard Surgical Dressing in Bilateral TKA
|
N/A | |
| Completed |
NCT05650970 -
Radial Nerve Mobilization in Hand Thumb Osteoarthritis Patients
|
N/A | |
| Recruiting |
NCT06074744 -
Subsartorial Nerve Block and Femoral Nerve Block in Total Knee Arthroplasty
|
N/A | |
| Completed |
NCT02315664 -
MONITOR-OA: Using Wearable Activity Trackers to Improve Physical Activity in Knee Osteoarthritis
|
N/A |