A crossover clinical trial investigates two novel CAD/CAM techniques for complete removable dental prostheses for edentulous patients, milling and rapid prototyping (3D-printing) in a clinical setting of an undergraduate student clinic. Outcome parameters concern the dentures' trueness, retention, stability, esthetics and occlusion. Secondary outcome parameters include willingness to pay and prosthetic maintenance need.


Clinical Trial Description

The process of fabricating complete removable dental prostheses (CRDPs) by novel CAD/CAM manufacturing technique has in the recent years gained immense popularity with clinicians as well as dental technicians worldwide. CRDPs can be manufactured by a subtractive process (milling technique) or by an additive process (rapid prototyping or 3D printing). The milling technique is the frequently employed technique for fabricating CRDPs; it is well documented in terms of precision, material properties, and a few clinical trials have even demonstrated good patient and clinician satisfaction. The rapid prototyping (3D printing) method however, is still in the developing stages for this particular application. Although both methods seem to yield clinically acceptable results, there are no studies in current literature which compare the CRDPs manufactured by the two CAD/CAM methods. The proposed single-center, double-blind, randomized crossover clinical trial specifically aims to test the following hypothesis that: • there is no difference between the two types of CRDPs (milled, and rapidly prototyped) in terms of trueness, denture quality, patient satisfaction, prosthodontic maintenance and adjustments requirements and incurred costs. Fifteen pre-doctoral final year dental students and their respective completely edentulous patients will be recruited in this RCT. A traditional clinical complete denture protocol will be followed to record the clinical steps. Two sets of CRDPs will be manufactured (CAD/CAM milling and 3D printing). The CRDPs will be randomized before denture insertion and then delivered to the patient. Each CRDPs will be worn by the patient for a period of 6 weeks, before crossing over. Clinical examinations and data collection will be performed at baseline (T0), at denture insertion stage (T1), and at the end of 6 weeks (T2) for each of the investigated CRDPs. Assessments will comprise of comparison of trueness of denture intaglio surfaces against the corresponding master cast, denture quality assessments, patient satisfaction scores, prosthodontic maintenance needs and willingness-to-pay analysis and cost minimization analysis. This RCT will contribute significantly in the development of CAD/CAM treatment concepts for fabricating complete removable dental prostheses (CRDPs). The study would highlight the differences, if any, between the two manufacturing methods for CRDPs, in terms of trueness, quality of the prostheses, clinician and patient satisfaction and also incurred costs. Clinically, the planned RCT hopes to demonstrate the feasibility of these novel treatment concepts in frail elderly edentates. A significant reduction in the treatment times, maintenance visits, and costs along with high patient satisfaction with these newer CRDPs would be added advantages when treating the elderly edentates. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04873219
Study type Interventional
Source University of Geneva, Switzerland
Contact
Status Completed
Phase N/A
Start date September 15, 2018
Completion date March 1, 2020

See also
  Status Clinical Trial Phase
Active, not recruiting NCT06408506 - In-patient Comparison of Immediately Loaded and Non-loaded Submerged and Transgingival Healed Implants Within 4 Months N/A
Active, not recruiting NCT05355792 - Multicenter Study to Evaluate the Clinical Outcome of the OmniTaper EV Implant in Single Tooth Restorations N/A
Terminated NCT00748670 - Treatment With Fixture Microthread™ in Patients With Poor Bone Quality and no Teeth in the Upper Jaw, When Using Two-Stage Surgery N/A
Active, not recruiting NCT04545840 - Prospective Neodent® Zirconia System Study
Completed NCT00922935 - Comparison of Early and Late Loading in the Edentulous Upper Jaw Using Cresco Prosthetic System on Straumann Implants Phase 4
Completed NCT00959530 - Comparison of Lingualized and Full Bilaterally Balanced Articulation N/A
Completed NCT00905840 - A Study to Treat Patients With Edentulous Mandibles With Two Straumann 3.3mm Diameter Bone Level Implants N/A
Completed NCT00711022 - Study on ASTRA TECH Implant System, OsseoSpeed™ Implants in Patients Missing All Teeth in the Upper Jaw, Restored With Provisional Teeth Within 24 Hours N/A
Terminated NCT00295126 - REPI : a Randomized Open Label Trial Evaluating the Use of APC in Pre-Implantation Reconstruction of Maxilla Phase 2/Phase 3
Recruiting NCT03957265 - Prospective Observational Study of SynCone® Concept Phase 1
Completed NCT01909999 - Release of Osteogenic Markers in Immediately and Non-loaded Dental Implants N/A
Completed NCT00901017 - Comparison of Synthetic Bone Substitute and a Bovine-derived Xenograft in Horizontal Bone Augmentation N/A
Completed NCT01641198 - An Implant With an Acid-etched Fixture Surface and Internal-hex Collar May Achieve Greater Osseointegration. N/A
Completed NCT03862482 - Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function N/A
Completed NCT01878331 - Long-term Study to Evaluate Different Dental Implant Alloys in Straumann 3.3mm Diameter Bone Level Implants
Completed NCT02418117 - Accuracy of Computer Guided Implant Surgery N/A
Completed NCT02107612 - Randomized Study For Minimally Invasive Splinted Implants N/A
Active, not recruiting NCT05007691 - Comparative Study of Maxillary and Mandibular Splints Used for the Treatment of Masticatory Muscle Parafunction (FEA) N/A
Active, not recruiting NCT04328116 - Study of Neodent Implantable Devices of GM Zygomatic Line
Completed NCT05032170 - Intraoral Scanning Accuracy in the Edentulous Mandible