Clinical Trials Logo

Clinical Trial Summary

The Neodent® Zirconia Implant is designed for the treatment of oral endosteal implantation for the functional and aesthetic rehabilitation, allowing for treatment of patients with different bone qualities. The objective of the study is to assess the success and survival rates of implantable devices of the Zirconia System, in order to confirm the long-term safety and clinical performance of implants and abutments of the Zirconia System in daily dental practice setting. Devices will be used according to standard routine in daily practice, according to manufacturer indications in the IFU. Patients will be followed for 36 months after implant placement.


Clinical Trial Description

The study protocol was reviewed and approved by an Ethics Committee (CE) in Brazil. The sample will be prospectively and consecutively selected and will consist of patients who are 18 years of age or older, who are in need of and who qualify for single dental implants placement in the posterior maxilla region with Neodent® Zirconia. Informed consent in writing will be obtained from each patient participating in the study prior to any study related procedure. As this study will be analyzed descriptively, sample size calculation was not performed. To generate reliable results, a total number of 30 implants was assumed to be sufficient. Estimating a rate of 1 implant per patient and a drop-out rate of 15%, a sample size of 36 patients resulting in an estimated number of 36 implants is thought to be sufficient to allow for a descriptive analysis of clinical outcome data up to 36 months after implant placement. Treatment provided to the subjects will be the responsibility of an appropriately qualified dental practitioner to provide the relevant patient care under clinical study conditions. Zirconia Implants will be placed under local anesthesia and with adequate bone bed preparation in posterior maxilla region. More than one implant can be placed in the same patient, as long as the subject presents natural teeth adjacent to the implant site. Immediately after implant placement, the final placement torque will be registered. The immediate loading will be applied within 48 hours with the insertion of a provisional prosthesis made from intraoral scanning or scanning of dental casts obtained by conventional impression. The insertion torque shall reach at least 35 N.cm and the subject must have physiologic occlusion to immediate loading. If the patient does not reach the minimum torque (35 N.cm), the patient will be followed until the study end but will not be considered to final statistic or, a different implant line would be placed and the study termination form will be filled. The principal investigator will choose how to procedure in this situation. The selection of the prosthetic component shall be conducted according to the need of each subject and to the manufacturer's instructions (IFU). The final prosthesis will be placed 2 months after implant loading. Data concerning the studied variables will be collected following the procedures and assessments plan by fulfilling the Case Report Form (CRF), in the following stages: screening (First visit); TP - Implant(s) placement and impression/scanning for temporary prosthesis preparation; T0 - Implant(s) loading (up to 48h after placement); TF - Final prosthesis placement (2 months ± 1 week after loading); T6, T12, T24, T36 - 6, 12, 24 e 36 ± 1 month, respectively, after loading. Standardized digital periapical radiographs will be obtained in a usual daily practice frequency, as determined by the investigator: at pre-operative, to assess the ridge height and width of the supporting bone and locate major anatomical features; in post-surgery (TP) and in T0, TF, T6, T12, T24 and T36 to verify prosthesis adaptation and osseointegration. Computed tomography scans will be obtained from the region of interest prior to surgery, for the selection of the implant to be inserted. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04545840
Study type Observational
Source Neodent
Contact
Status Active, not recruiting
Phase
Start date September 10, 2020
Completion date December 30, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT02880891 - Effects of Splinted or Non-splinted Single-unit Crowns on Marginal Bone-level Alterations Around Implants N/A
Completed NCT00748241 - Study to Evaluate Implant Survival Rate of Astra Tech Fixture ST in the Posterior Maxilla With One-stage Surgery and Early Loading N/A
Active, not recruiting NCT04066309 - Implant Retained Rehabilitation With Surgical and Prosthetic Digital Workflow N/A
Active, not recruiting NCT06034067 - Osseodensification Versus Conventional Drilling for Implant Site Preparation N/A
Active, not recruiting NCT04546269 - Fully Guided Versus Conventionally Guided Implant Placement by Dental Students N/A
Recruiting NCT02676661 - Evaluation of the Prevalence and Risk Factors for Patients With Peri-implant Disease N/A
Recruiting NCT02662361 - Evaluation of the Prevalence and Risk Factors for Patients With Peri-implant Diseaseļ¼ša Retrospective Study N/A
Completed NCT01030523 - Short Implants - An Alternative to Bone Grafting? N/A
Completed NCT00906425 - Clinical Study Comparing Submerged Versus Trans-mucosal Healing of P.004 Implants in the Anterior Mandible and Maxilla N/A
Completed NCT03252106 - Long-term Effectiveness of Contour Augmentation in Sites With Early Implant Placement N/A
Completed NCT02975674 - Evaluation of MT-12 Implant Survival and Marginal Bone Loss N/A
Completed NCT01822223 - A Study to Evaluate the Effectiveness of Laser-Ablated Implant-Abutments to Promote Tissue Healing N/A
Completed NCT00545818 - Study Comparing OsseoSpeedā„¢ Implants of Two Different Lengths in the Upper and Lower Posterior Jaw N/A
Completed NCT00900822 - Straumann Bone Ceramic Versus BioOss in Sinus Elevation N/A
Completed NCT04017026 - Survival and Success Rates of 6mm Implants With a Micro-rough Surface After 4.5 - 18.2 Years in Function
Active, not recruiting NCT05315414 - Multicenter Study to Evaluate the Clinical Outcome of PrimeTaper EV Implant in Single Tooth Restorations N/A
Recruiting NCT02814149 - Esthetic, Clinical and Radiographic Outcomes of Immediate and Delayed Implant Placement N/A
Active, not recruiting NCT03319758 - Esthetic and Radiographic Outcomes Following Immediate Implant Placement With Thin or Dehiscence Buccal Bone Wall N/A
Completed NCT01807416 - Bone Dimensional Changes at Different Implant-to-abutment Connections: a 1-year Clinical and Radiological Study Phase 4
Completed NCT01821092 - Dimensional Changes of Peri-implant Facial Bone Phase 4