Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to evaluate a new disposable supra-glottic airway device, the i-gel airway (Intersurgical Ltd., Wokingham, England). We propose to test its ease of insertion, position within the airway, drain tube patency and anatomic sealing properties during mechanical ventilation in non-obese anesthetized patients undergoing elective general surgery. The study device will be compared to the current standard in the industry, the LMA Unique.


Clinical Trial Description

During the past decade, several pharyngeal airways have been introduced for airway management, such as the Laryngeal Mask Airway (LMA), the Cobra perilaryngeal airway, the Esophageal Tracheal Combitube (ETC), the EasyTube, the Laryngeal Tube6, and the Streamlined Liner of the Pharyngeal Airway (SLIPA). These airway devices have become very popular because of their ability to maintain an airway without perturbing the trachea and can be used in patients without muscle relaxation who are only lightly anesthetized.

The LMA Classic (cLMA) generally provides an adequate airway, but certain problems remain:

1. In 8-33% of LMA placements, more than one attempt is required.

2. It is sometimes difficult to advance the LMA without extending the neck (which is contraindicated in some patients).

3. The device does not protect the airway from aspiration of gastric contents.

4. It does not provide an airtight seal around the larynx (the usual pressures causing leakage of gas being 15-20 cm H20). Consequently, the device may function poorly during positive-pressure ventilation.

5. The esophagus is included within the rim of the LMA in 10-15% of patients, directly exposing the esophagus to positive airway pressures. This often results in insufflation of the stomach and postoperative discomfort.

The LMA Unique (uLMA) is a disposable, inflatable supraglottic airway device that is based on the LMA Classic design which has been used as the "model" in the industry. It has been listed as a commonly accepted device for routine and rescue airway management and is now listed in the American Society of Anesthesiologists (ASA) Difficult Airway Management Algorithm as an airway conduit for tracheal intubation.

The i-gel (Intersurgical Ltd., Wokingham, England) is a cuffless, single-use supraglottic airway device designed to provide a more effective seal than the uLMA, thus eliminating problems 3-5 described above with the addition of a gastric drain. Made of a gel-like thermoplastic elastomer, the i-gel has an anatomically-designed mask that allows quick, easy insertion and can accurately position itself over the laryngeal framework to provide a reliable perilaryngeal seal without the need for an inflatable cuff. In a preliminary study, the peak airway pressures were found to be above 30 cm H2O with a sustained leak pressure of 24 cm H2O versus an average of 18-21 cm H2O seen with the cLMA. According to the 100 patient trial, the i-gel is easier to insert, it has better sealing properties and there is no cuffed inflates.

This clinical study has been designed to compare the i-gel and the uLMA, as to ease of placement, ventilation during mechanical ventilation, proper positioning, seal pressures, the patency of the drain tube, and finally, any complications with their use. Fiberoptic observations through each device will provide information in relation to the epiglottis and the distal opening of the device. ;


Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Subject), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00706823
Study type Interventional
Source The University of Texas Health Science Center, Houston
Contact
Status Completed
Phase N/A
Start date February 2008
Completion date August 2008

See also
  Status Clinical Trial Phase
Completed NCT03277872 - NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope N/A
Suspended NCT04253795 - Nonintubated Versus Intubated Anesthesia in Video-assisted Thoracic Surgery N/A
Completed NCT02864017 - Immuno Nutrition by L-citrulline for Critically Ill Patients N/A
Completed NCT02900807 - CT-scan Airways Mensuration - Correlation to External Measurements
Completed NCT01823328 - Ketamine Versus Etomidate for Rapid Sequence Intubation Phase 4
Completed NCT02350933 - Endoscopic Evaluation of the Paediatric Airway After Prior Prolonged (>24 h) Tracheal Intubation N/A
Completed NCT01170455 - Nasal Intubation Using the Blind Intubation Device N/A
Completed NCT00980590 - Airway Scope and Macintosh Laryngoscope for Tracheal Intubation in Patients Lying on the Ground N/A
Completed NCT05515107 - The Laryngoscopic View With C-MAC Videolaryngoscope Miller Blade Lifting the Epiglottis or the Vallecula in Children N/A
Completed NCT06249659 - Impact of Extubation Location After Surgery on Perioperative Times
Completed NCT03677505 - KoMAC Videolaryngoscope for Double-lumen Intubation N/A
Completed NCT03328182 - Assessment of an Oral Endotracheal Subglottic Tube Holder N/A
Recruiting NCT02073786 - Rigid Video Stylet Vs Conventional Lightwand Intubation N/A
Recruiting NCT02277405 - Pediatric Intubation During Resuscitation N/A
Recruiting NCT02277652 - Endotracheal Intubation Devices N/A
Completed NCT02277418 - Venner a.p. Advance Video Laryngoscope N/A
Completed NCT01003327 - Comparison of the I-gel Laryngeal Mask and the Classic Laryngeal Mask in Patients With a BMI>25 Phase 4
Completed NCT00956592 - Clinical Evaluation of the Storz CMAC Laryngoscope N/A
Completed NCT00783731 - Low Dose of Midazolam is Superior to Conventional Dose for Rapid Sequence Intubation in Emergency Department (ED) N/A
Recruiting NCT03887897 - First Attempt Intubation Rate With Airtraq vs Macintosh Direct Laryngoscope N/A