Intubation;Difficult Clinical Trial
Official title:
Airtraq Versus Fiberoptic for Awake Tracheal Intubation : A Randomised Non-inferiority Trial
The airway management is a vital act in anesthesia. The gold standard technique for planned very difficult intubation is nasotracheal fiberoptic intubation. The success rate with this procedure is 98.8%. However, learning this technique is difficult and it's considered uncomfortable by patients and practitioners. The Airtraq® videolaryngoscope is commonly used for difficult orotracheal intubation. Cases of awake intubation by Airtraq® have been described. Furthermore, the French Society of Anesthesia-Resuscitation, in its last formalized expert recommendations (2017) on difficult intubation, proposes the use of video laryngoscopes as an alternative to the fiberoptic bronchoscope. We propose a non-inferiority study evaluating the use of Airtraq® for the realization of a awake intubation compared to the gold standard (fiberoptic bronchoscope). This prospective randomized study should include 78 patients in two groups. The purpose of this study is to improve the comfort of patient and practitioner during an awake tracheal intubation, to facilitate the learning of the technique.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03604120 -
Preoxygenation for Difficult Airway Management
|
N/A | |
Completed |
NCT04356547 -
Orotracheal Intubation Using Flexible Fibro Bronchoscope With vs Without Supraglottic Device
|
N/A | |
Completed |
NCT03645174 -
Long Endotracheal Tube vs. Aintree Intubating Catheter for Fiberoptic-guided Intubation in Manikin
|
N/A | |
Completed |
NCT03578601 -
Predictive Parameters for Difficult Tracheal Intubation Identification in Thyroid Surgery
|
||
Completed |
NCT04578119 -
Optimal Intubating Technique Using Videolaryngoscopy in Patients With Semi-rigid Neck Collar
|
N/A | |
Terminated |
NCT03340207 -
Novel Airway Device to Aid Endotracheal Intubations
|
N/A | |
Completed |
NCT04091568 -
Patient Experience Following Awake Fibreoptic Intubation Compared to Asleep Fibreoptic Intubation
|
||
Completed |
NCT03337555 -
A Comparison of McGrath MAC®, Pentax-AWS® and Macintosh Direct Laryngoscopes for Nasotracheal Intubation
|
N/A | |
Completed |
NCT04153357 -
Comparison of Different Video Laryngoscopes in < 1 Year Old Undergoing Neurosurgical Operations: a Prospective Randomized Study
|
N/A | |
Recruiting |
NCT03366311 -
TCHCCT-Zhong-Xing-Emergency-Department-airway
|
N/A | |
Completed |
NCT03719638 -
Comparison of Two Blades of Videolaryngoscope in Simulated Difficult Airway in Children
|
N/A | |
Completed |
NCT03716466 -
Evaluation of Prophylactic Endotracheal Intubation
|
||
Recruiting |
NCT03514745 -
Comparison of Lighted Stylet and GlideScope for Double-lumen Endobronchial Intubation
|
N/A | |
Completed |
NCT03118622 -
Pentax Videolaryngoscopy in Children
|
N/A | |
Completed |
NCT03173443 -
Insertion Time Over Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube
|
N/A | |
Completed |
NCT03576352 -
Emergency Front of the NecK Access (eFONA) in Children
|
N/A | |
Completed |
NCT04457453 -
Comparison of Direct and Video Laryngoscope During Endotracheal Intubation in Sellick and Trendelenburg Position
|
N/A | |
Not yet recruiting |
NCT04770077 -
Sniper Intubation for Training of Undergraduate Medical Student
|
||
Recruiting |
NCT06448377 -
Initiation of Airway Code: The Role of the Airway Team in Unexpected Difficult Airways
|
||
Completed |
NCT04779528 -
Awake Nasal Fiber-optic Intubation of Severely Obese Patients in Lateral Position
|
N/A |