Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02387502
Other study ID # 123-IEC/01/13
Secondary ID
Status Completed
Phase N/A
First received March 2, 2015
Last updated April 28, 2015
Start date January 2014
Est. completion date December 2014

Study information

Verified date April 2015
Source Government Medical College, Haldwani
Contact n/a
Is FDA regulated No
Health authority India: Indian Council of Medical Research
Study type Interventional

Clinical Trial Summary

Tracheal intubation requires alignment of oro-pharyngeal-laryngeal axes. When these three axes are not aligned, intubation becomes difficult. In the researchers' study, the investigators simulated difficult laryngoscopy situation by using a rigid neck collar. This neck collar renders intubation difficult not only by restricting neck movement, but also reducing mouth opening. The investigators compared the performance of Macintosh, MacCoy and Airtraq laryngoscope in simulated difficult laryngoscopy using a rigid neck collar.


Description:

Airtraq laryngoscope is an optical laryngoscope which allows visualization of vocal cord as a reflected image through multiple lenses and prisms. MacCoy laryngoscope is a modification of Macintosh laryngoscope. It has a lever which, when pressed, moves its flexible tip. In the investigators' study, the researchers compared the performances of Airtraq laryngoscope with MacCoy and Macintosh laryngoscopes in simulated difficult laryngoscopy using a rigid neck collar. The researchers recruited 120 patients and randomly divided those patients into three equal groups i.e. 30 patients in each group. These three groups are 1-Airtraq, 2-MacCoy and 3-Macintosh. The researchers compared efficacy and safety in these three laryngoscopes. The researchers compared efficacy in terms of time of intubation, ease of intubation, overall success, Intubation difficulty score, visualization of vocal cord in terms of POGO (percentage of Glottic Opening) score. The researchers compared safety in terms of hemodynamic pressor response and airway trauma.


Recruitment information / eligibility

Status Completed
Enrollment 120
Est. completion date December 2014
Est. primary completion date December 2014
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 60 Years
Eligibility Inclusion Criteria:

- American Society of Anesthesiologists (ASA) physical status I and II.

- Posted for elective surgery requiring general anesthesia and tracheal intubation

Exclusion Criteria:

- patients with anticipated difficult airway

- obese (body mass index (BMI)>30) patients

- patients with risk of pulmonary aspiration of gastric contents

- pregnant patients

- patients with airway distortion or trauma.

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Device:
Intubation- Macintosh laryngoscope
Difficult intubation was simulated by using rigid neck collar. Then patients were intubated according to the assigned laryngoscopes. In Macintosh group, tip of the laryngoscope blade was placed in the vallecula and epiglottis was lifted. After visualization of the vocal cord, patients were intubated.
Intubation- MacCoy laryngoscope
In MacCoy group, tip of the laryngoscope blade was placed in the vallecula and lever was pressed to flex the tip. After visualization of the vocal cord, patients were intubated.
Intubation- Airtraq laryngoscope
In Airtraq group, the laryngoscope was loaded with endotracheal tube. Airtraq laryngoscope was inserted through midline and after visualization of image of vocal cord through its eyepiece, endotracheal tube was passed.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Government Medical College, Haldwani

Outcome

Type Measure Description Time frame Safety issue
Primary Time of Intubation Time of intubation is defined as the time from passing the device beyond the incisors to the confirmation of endotracheal tube placement by square wave capnograph tracings. up to 10 minutes No
See also
  Status Clinical Trial Phase
Recruiting NCT02922595 - Comparison of iLTS-D® and ILMA® for Intubation With Fiberoptic Control N/A
Completed NCT02051400 - Evaluation of McGrath® MAC Video Laryngoscope N/A
Completed NCT01965938 - RIFL (Rigid and Flexing Laryngoscope) vs. Fiberoptic Bronchoscope N/A
Completed NCT02769819 - Identification of Morphological Characteristics to Predict Difficult Endotracheal Intubation Using a Flexible Fiberscope N/A
Completed NCT02362568 - Study of Interest on Cervical Ultrasound Exploration for Association With Difficult Intubation N/A
Completed NCT01692522 - Comparison of the Laryngeal Mask Ambu Aura-i Versus AirQ in Children N/A
Recruiting NCT03035786 - Airway Code Calls - Survey of Management N/A
Completed NCT02290249 - Intubation of a Pediatric Manikin in Difficult Airway by Novice Personnel: A Comparison of Glidescope and Airtraq Phase 4
Completed NCT02326896 - MACOCHA Score Predicts Intubation Failure N/A
Completed NCT01984970 - McGrath Series 5 Videolaryngoscope for Double-lumen Tube Intubation N/A
Completed NCT01474213 - Sedation Effect of Dexmedetomidine Versus Remifentanil to Fibreoptic Intubation Phase 4
Terminated NCT00464490 - Use of Dexmedetomidine to Facilitate Extubation in Surgical ICU Patients Who Failed Previous Weaning Attempts N/A
Not yet recruiting NCT02430415 - Laryngoscope-assisted Lightwand Intubation and Cervical Spine Motion N/A
Completed NCT01375634 - Nasogastric Tube Insertion Using Midazolam in the Emergency Department Phase 4
Completed NCT01464489 - Intubation Time With Low Dose Rocuronium N/A
Terminated NCT01075789 - Using Lignocaine Spray and Gel to Reduce the Pain Associated With Nasogastric Tube Insertion in Children N/A
Recruiting NCT02501577 - Comparison of Various Supraglottic Airway Devices for Fiberoptical Guided Tracheal Intubation N/A
Completed NCT02566135 - I-gel Versus Classic-Laryngeal Mask Airway (C-LMA) as a Conduit for Tracheal Intubation Using Ventilating Bougie N/A
Recruiting NCT02493478 - Improving Safety and Quality of Tracheal Intubation Practice in Pediatric ICUs
Completed NCT02198742 - A Comparison Between Two Video Laryngoscopes,in Successfully Intubating Pediatric Mannequins w/wo Difficult Airways Phase 1