Clinical Trials Logo

Clinical Trial Summary

Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU. The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP. When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies. The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time. The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory.


Clinical Trial Description

Central venous pressure (CVP) is a parameter used very regularly in pediatric resuscitation units. According to international recommendations, it should be measured during resuscitation of acute circulatory failure, severe head trauma, renal transplantation in low weight children, or to indirectly assess systolic pulmonary artery pressure by the tricuspid leak gradient. The baseline measurement should be performed using a central venous catheter placed at the right atrial outlet. However, in clinical practice, trans-thoracic echocardiography (TTE) is the most widely used hemodynamic examination in PRU because of its simplicity of use and the excellent echogenicity of patients. While this technique allows assessment of CVP in spontaneously ventilated adults, it is not recommended in positively ventilated adults. Similarly, no pediatric study has formally demonstrated that TTE parameters allow reliable estimation of CVP in mechanically ventilated children, who represent a significant proportion of patients hospitalized in PRUs. The investigators therefore propose to validate TTE assessment of CVP in children on MV in PRU. The investigators wish to carry out a prospective, non-interventional study over 12 months in 6 pediatric intensive care units in France. The main objective will be to study the correlation between the measurement of the collapsibility index, the distensibility index of the inferior vena cava and the ratio of the maximum diameter of the IVC to the diameter of the abdominal aorta with the measurement of the CVP. When a patient meets the inclusion criteria, oral information and a paper record will be given to the parental authority holders by the investigator or a physician representing the investigator. After a reflection period of at least 3 hours, the non-objection will be sought and noted in the file. The patient will then be managed according to standard ICU care. The CVP measurements and ultrasound parameters, collected as part of the study, must be carried out in succession, without modifying the ventilator settings or the current therapies. The first step will be to measure the CVP on 3 occasions, at 30 second intervals, checking for the absence of spontaneous respiration or extra systole that has modified the appearance of the curve. The 2nd step will be to perform the cardiac ultrasound with measurements taken 3 times, at 30 second intervals, repositioning the ETT probe each time. The investigators hypothesize that the cardiac ultrasound allows to estimate the central venous pressure in pediatric patients, intubated and ventilated in positive pressure thanks to the measurement of these parameters. If confirmed, this data would allow validation of CVP estimation via a simple and noninvasive examination in children in VM. Furthermore, according to the recommendations, the examination of CVP via the catheter requires strict criteria on the position of the catheter (in the superior vena cava territory and at the right atrial junction). Estimation of CVP via ultrasound would therefore make it possible to obtain this data in patients whose catheter does not respect the required position, particularly patients with a catheter in the lower territory. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05195424
Study type Observational
Source Assistance Publique - Hôpitaux de Paris
Contact Perrine SEE, MD
Phone +33609829706
Email perrine.see@aphp.fr
Status Recruiting
Phase
Start date November 3, 2021
Completion date November 3, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05717907 - Suction Catheter as a Guide for Nasotracheal Intubation Under General Anesthesia N/A
Completed NCT03653910 - Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope N/A
Recruiting NCT04190524 - Sonographic Assessment of Cricoid Pressure N/A
Completed NCT02359370 - The Effects of Lidocaine and Magnesium Sulphate on the Attenuation of the Hemodynamic Response to Tracheal Intubation Phase 4
Not yet recruiting NCT05036460 - Real-time Sonography in Detecting Inadvertent Esophageal Intubation Among Difficult Intubation Patients N/A
Completed NCT03992950 - Effectiveness of Cricoid and Paratracheal Pressures for Occluding Esophagus N/A
Completed NCT05502120 - A Comparison of Vie-Scope and Macintosh Blade Laryngoscopes in Morbidly Obese. N/A
Completed NCT05303948 - Evaluation of Two Positions for Free Floating Tracheal Intubation in Weightlessness N/A
Completed NCT03720093 - Exploratory Analysis of Pulmonary Microbiome in Intubated Patients
Recruiting NCT03031808 - Comparison of Two Induction Regimens Using Topical Lidocaine or Muscle Relaxant on Sore Throat and Hemodynamics Phase 4
Not yet recruiting NCT02918526 - Hemodynamic Study With PRAM of the Cardiovascular Response to the Positioning of the Extraglottic Device N/A
Completed NCT02364622 - The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube N/A
Completed NCT05249738 - Tongue Edema Caused by Intubation Tube in Intensive Care Unit Patients
Completed NCT03842306 - End-tidal Oxygen Can Reliably Predict the Arterial Partial Pressure of Oxygen Among Emergency Department Patients
Terminated NCT03340207 - Novel Airway Device to Aid Endotracheal Intubations N/A
Recruiting NCT05782517 - I-gel vs. Endotracheal Intubation for Laparoscopic Gynaecological Procedures N/A
Recruiting NCT06085326 - Smart Checklist Implementation for Pediatric Tracheal Intubations in the ICU- Multicenter Study N/A
Active, not recruiting NCT06108271 - Innovative Endotracheal Tube Design Reduces Postoperative Laryngeal Injury N/A
Completed NCT05668299 - Determining the Appropriate Setting of an Automated Secretion Removal Technology (TrachFlush) N/A
Completed NCT04079387 - Effect of Endotracheal Tube Plus STYLET Versus Endotracheal Tube Alone N/A