Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02190201
Other study ID # TJMZK201405001
Secondary ID
Status Completed
Phase Phase 4
First received July 10, 2014
Last updated November 19, 2014
Start date July 2014
Est. completion date November 2014

Study information

Verified date November 2014
Source Huazhong University of Science and Technology
Contact n/a
Is FDA regulated No
Health authority China: National Natural Science FoundationChina: Ministry of Health
Study type Interventional

Clinical Trial Summary

The investigators previous study showed that McGrath Series 5 videolaryngoscope is an alternative tool for double-lumen tube intubation. But it is not determined about the advantages and disadvantages of McGrath Series 5 videolaryngoscope for double-lumen tube intubation, compared with traditional Macintosh laryngoscope.


Description:

The investigators designed a randomised controlled study to compare of McGrath Series 5 videolaryngoscope and Macintosh laryngoscope for DLT intubation.


Recruitment information / eligibility

Status Completed
Enrollment 114
Est. completion date November 2014
Est. primary completion date November 2014
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 70 Years
Eligibility Inclusion Criteria:

- Adult patients

- Thoracic surgery required one lung ventilation

Exclusion Criteria:

- Difficult ventilation

- Emergent operation

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment


Intervention

Device:
videolaryngoscope
a kind of videolaryngoscopes, which are widely used in difficult airways.
Direct laryngoscope
A kind of traditional laryngoscopes

Locations

Country Name City State
China Tongji Hospital, Huazhong University of Science and Technology Wuhan Hubei

Sponsors (1)

Lead Sponsor Collaborator
Huazhong University of Science and Technology

Country where clinical trial is conducted

China, 

Outcome

Type Measure Description Time frame Safety issue
Other Airway evaluation with Cormack-Lehane Score based on Cormack-Lehane classification. degree 1 to 4 At intubation No
Primary Intubation time measured with a stopwatch, defined as time from inserting blade to mouth to withdrawal of blade at intubation No
Secondary number of successful intubation at first attempt at intubation Yes
See also
  Status Clinical Trial Phase
Active, not recruiting NCT05717907 - Suction Catheter as a Guide for Nasotracheal Intubation Under General Anesthesia N/A
Completed NCT03653910 - Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope N/A
Recruiting NCT04190524 - Sonographic Assessment of Cricoid Pressure N/A
Completed NCT02359370 - The Effects of Lidocaine and Magnesium Sulphate on the Attenuation of the Hemodynamic Response to Tracheal Intubation Phase 4
Not yet recruiting NCT05036460 - Real-time Sonography in Detecting Inadvertent Esophageal Intubation Among Difficult Intubation Patients N/A
Completed NCT05502120 - A Comparison of Vie-Scope and Macintosh Blade Laryngoscopes in Morbidly Obese. N/A
Completed NCT03992950 - Effectiveness of Cricoid and Paratracheal Pressures for Occluding Esophagus N/A
Completed NCT05303948 - Evaluation of Two Positions for Free Floating Tracheal Intubation in Weightlessness N/A
Completed NCT03720093 - Exploratory Analysis of Pulmonary Microbiome in Intubated Patients
Recruiting NCT03031808 - Comparison of Two Induction Regimens Using Topical Lidocaine or Muscle Relaxant on Sore Throat and Hemodynamics Phase 4
Not yet recruiting NCT02918526 - Hemodynamic Study With PRAM of the Cardiovascular Response to the Positioning of the Extraglottic Device N/A
Completed NCT02364622 - The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube N/A
Completed NCT05249738 - Tongue Edema Caused by Intubation Tube in Intensive Care Unit Patients
Completed NCT03842306 - End-tidal Oxygen Can Reliably Predict the Arterial Partial Pressure of Oxygen Among Emergency Department Patients
Terminated NCT03340207 - Novel Airway Device to Aid Endotracheal Intubations N/A
Recruiting NCT05782517 - I-gel vs. Endotracheal Intubation for Laparoscopic Gynaecological Procedures N/A
Recruiting NCT06085326 - Smart Checklist Implementation for Pediatric Tracheal Intubations in the ICU- Multicenter Study N/A
Active, not recruiting NCT06108271 - Innovative Endotracheal Tube Design Reduces Postoperative Laryngeal Injury N/A
Completed NCT05668299 - Determining the Appropriate Setting of an Automated Secretion Removal Technology (TrachFlush) N/A
Completed NCT04079387 - Effect of Endotracheal Tube Plus STYLET Versus Endotracheal Tube Alone N/A