Inflammatory Bowel Disease Clinical Trial
Official title:
Prospective Randomized Trial of Anterograde Single Balloon Versus Spirus Enteroscopy in Patients With Suspected Small Bowel Disease
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical
differences from the colon and the upper gastrointestinal tract. The small bowel has an
average length of 6.7 m, with a free mesentery that resists standard "push to advance"
endoscopy techniques. New developments in overtubes, which are placed over an enteroscope,
have revolutionized doctors ability to deeply intubate the small bowel. Three types of
'augmented' enteroscopy, double balloon enteroscopy (DBE), single balloon enteroscopy (SBE)
and spiral enteroscopy (SE), have been developed. Although studies have been performed on
these individual techniques, there are no studies comparing SBE and SE, the two techniques
used in Johns Hopkins.
The investigators propose performing a prospective, randomised trial, to assess the
differences between these two techniques. The question of what differences there are between
these two techniques, in terms of depth of insertion, diagnostic and therapeutic yields,
time required for the procedure and the sedation requirements, are important questions to
answer, and depending on the results, would affect the investigators approach to patients
with small bowel disease.
We currently perform both spiral enteroscopy (SE) and single balloon enteroscopy (SBE) in
Johns Hopkins Hospital. The decision as to which procedure to use is determined by the
endoscopist performing the procedure, with currently approximately 60% being performed with
SE and 40% performed with SBE. We wish to perform a prospective, randomised trial, to assess
the differences between these two procedures. The question of what differences there are
between these two techniques, in terms of depth of insertion, diagnostic and therapeutic
yields, time required for the procedure and the sedation requirements, are important
questions to answer, and depending on the results, would affect the investigators approach
to patients with small bowel disease.
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical
differences from the colon and the upper gastrointestinal tract. The small bowel has an
average length of 6.7 m, with a free mesentery that resists standard "push to advance"
endoscopy techniques. New developments in overtubes, which are placed over an enteroscope,
have revolutionized the investigators ability to deeply intubate the small bowel. The first
of these new techniques to be described was double balloon enteroscopy (DBE) (Fujinon,
Wayne, NJ) in 2001. The next development was single balloon enteroscopy (SBE) (Olympus
America, Center Valley PA), an iteration of DBE that simply forgoes the second balloon at
the tip of the endoscope, and also allows for deep enteroscopy which has been available in
the United States since 2007. Spiral enteroscopy (SE) was introduced soon after SBE in 2007,
and consists of a spiral overtube (Spirus Medical Inc., Stoughton, Massachusetts, USA) which
pleats the small bowel onto the enteroscope.
DBE has the largest amount of published data, with more than 1370 patients and 2591
examinations. Data regarding the efficacy of SBE and SE are more limited than DBE. SBE and
SE have only been available in the United States since 2007, and therefore have less
published data than DBE. There are two published series of SBE, with several more
publications in abstract form. A total of 362 cases have been reported, with diagnostic
yields ranging between 30% to 76%, with therapeutic intervention performed in up to 55%.
There are 6 reports of SE procedures, with one large series of 1750 cases documenting side
effects of SE. The overall diagnostic yield ranged from 24% to 51% with similar treatment
success rates. SBE has been compared with DBE in patients with suspected small bowel disease
in three studies reported in abstract form. SE has been compared with push enteroscopy and
DBE, however there have been no studies comparing SBE and SE.
The risks associated with augmented enteroscopy (DBE, SBE, SE) are similar to those
associated with routine endoscopy and include sedation-related complications, aspiration
pneumonia, and respiratory infections. In addition, there have been complications
specifically related to augmented enteroscopy. Abdominal discomfort can occur due to trapped
gas. DBE has been associated with intestinal cramping in 2% to 20% of patients. The use of
CO2, which the investigators routinely use in Johns Hopkins, decreases post procedure
abdominal cramping. Minor small bowel contusion can occur. The incidence of gastrointestinal
haemorrhage does not seem to be increased in augmented enteroscopy compared with standard
endoscopic procedures. Pancreatitis occurred in 6 (0.2%) of cases reported in a multicenter
United States study of DBE. There have been no reports of pancreatitis associated with SBE
or SE enteroscopy. Intestinal perforation is a rare but serious event. Perforation has been
reported in 5 (0.2%) of 2591 DBE examinations. In SBE, one perforation was reported in a
series of 37 patients, with a case report of a perforation in a patients with jejuna
ulceration from metastatic adenocarcinoma of unknown primary. A mucosal tear, requiring
endoscopic clip esophageal or gastric perforation, severe bleeding requiring transfusion,
cardio-pulmonary arrests or deaths. There were 7 (0.4%) severe complications. Six were small
bowel perforations (0.34%).
In Johns Hopkins there has been one perforation using SBE and one using SE one of which
occurred in a patient with small bowel Crohns disease (SBE) and the other in a patient with
altered anatomy (SE) (personal communication Dr PI Okolo). This latter group of patients are
known to be at increased risk of perforation during endoscopic procedures and will be
excluded from this study. There have had no other serious complication associated with
either SE or SBE enteroscopy. All of the individuals who will participate in this study are
already scheduled to have an augmented enteroscopy. Therefore, there is no additional risk
incurred by the patient by participating in this study, over and above the risk of an
augmented enteroscopy which is part of the routine clinical care for these patients.
;
Observational Model: Case-Only, Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Withdrawn |
NCT03278912 -
Natural History of Intestinal Inflammation in People With Primary Immune Dysregulations
|
||
Terminated |
NCT00061282 -
Clotrimazole Enemas for Pouchitis in Children and Adults
|
Phase 1/Phase 2 | |
Recruiting |
NCT05579392 -
A Randomized Crossover Trial of Bright Light Therapy in Crohn's Disease on Intestinal Barrier Homeostasis
|
N/A | |
Completed |
NCT03264690 -
Study to Observe the Change in Microbiome in Human Derived Sample and the Relation With Clinical Response Before and After the Anti-TNF Treatment in IBD Patients
|
||
Recruiting |
NCT02861053 -
Inflammatory Bowel Disease : Could a Regular Physical Activity Reduce Patients Fatigue ?
|
N/A | |
Recruiting |
NCT02275676 -
Resting Energy Expenditure and Nutritional Status in IBD
|
N/A | |
Completed |
NCT02197780 -
Head-to-head Comparison of Two Fecal Biomarkers to Screen Children for IBD
|
N/A | |
Completed |
NCT02503696 -
Sample Collection Study to Evaluate DNA Markers in Subjects With Inflammatory Bowel Disease (IBD)
|
N/A | |
Completed |
NCT02161640 -
Vascular Dysfunction in Paediatric IBD
|
N/A | |
Completed |
NCT01933867 -
Water-aided Colonoscopy in Inflammatory Bowel Disease Patients
|
N/A | |
Completed |
NCT01852760 -
Assessment of Disease Activity in Ulcerative Colitis by Endoscopic Ultrasound
|
N/A | |
Completed |
NCT01860651 -
Web-based Monitoring in Children and Adolescents With Inflammatory Bowel Disease
|
N/A | |
Completed |
NCT01692743 -
Telemedicine in Patients With Inflammatory Bowel Disease (TELE-IBD)
|
Phase 3 | |
Completed |
NCT01666535 -
Infliximab IBD Influenza Vaccine Study
|
N/A | |
Completed |
NCT01676324 -
FOCUS: The Future of Fecal Calprotectin Utility Study for the Diagnosis and Management of Inflammatory Bowel Disease (IBD)
|
N/A | |
Completed |
NCT01688557 -
Trial on Innovative Technologies in Colonoscopy
|
N/A | |
Completed |
NCT01981616 -
Immune Response to Systemic and Mucosal Antigenic Challenge in the Presence of Vedolizumab
|
Phase 1 | |
Completed |
NCT01557387 -
Real-time Diagnosis of Pseudopolyps During Colonoscopy
|
||
Completed |
NCT01221818 -
A Randomized, Double-Blind, Placebo-Controlled, Ascending Single Dose Study of E6007 in Healthy Subjects
|
Phase 1 | |
Completed |
NCT01476995 -
Prognostic Indicators as Provided by the EPIC ClearView
|
N/A |