Infection Control Clinical Trial
Official title:
Risk Assessment of Indirect Exposure to the Environment in the Gastrointestinal Endoscopy Center
Study objective: To clarify the risk of exposure to indirect contact and transmission of environmental objects during digestive endoscopy diagnosis and treatment for patients and medical staff, simulating by using Vitamin B2 solution. Study design: This is a case-only research.
In the study, the object surface of the digestive endoscopy room is preliminarily analyzed, and several key exposure units, such as potential high-frequency touch areas such as the surface of the bed unit, are screened and defined. A fluorescence photographing system is arranged in the digestive endoscopy room, and the exposure unit before treatment is photographed with the best excitation wavelength of the fluorescent marker as the light source, to get the experimental background reference. Then, patients undergoing digestive endoscopy in the same endoscopy work unit (usually half a day) are selected. Before entering the digestive center, the hands of patients are fluorescently marked with vitamin B2 mixed hand sanitizer 1ml (vitamin B2 0.12mg/ml). Meanwhile, the process of the gastroscopy is recorded by camera for the recognition of touch behaviors. Then, the doctors and nurses give routine care and procedure. Based on the fluorescence tracing and detection methods, the indoor light source is turned off after each selected endoscopy work unit, and the fluorescence residue on the surface of key exposed units is photographed. The environmental surfaces touched by the patient are sampled by the wiping method. Then the video of the gastroscopy process is analyzed for the recognition of touch behaviors. The dosage is detected by the Fluoro Max-4® fluorophotometer (HORIBA, Japan), which is quantified as a cumulative mass (μg) over all the exposure time. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04529421 -
Assocation Between In-person Instruction and COVID-19 Risk
|
||
Recruiting |
NCT02944695 -
Audit of Bronchoscopy Practice in Egypt: Adherence to Safety and Infection Control Guidelines
|
||
Active, not recruiting |
NCT01069497 -
Preventability of Infections in Residents of French Nursing Homes
|
N/A | |
Completed |
NCT02965989 -
Effectiveness of a Online Training Program With a Clinical Procedure Standardized in Units of Nursing (CPSUN)
|
N/A | |
Recruiting |
NCT05597072 -
Bacterial Air Contamination
|
N/A | |
Completed |
NCT04212130 -
Can Environmental Cleanliness be Assessed by BCA (Bicinchoninic Acid) Method
|
N/A | |
Completed |
NCT03075813 -
Early Recognition and Response to Increases in Surgical Site Infections Using Optimized Statistical Process Control Charts: The Early 2RIS Study
|
N/A | |
Completed |
NCT05540886 -
CLEAN Frontline: A Stepped Wedge Cluster Trial
|
N/A | |
Recruiting |
NCT04783025 -
A Blended Gaming COVID-19 Training System (BGCTS) With WHO Guidelines for Staff in Residential Care Homes
|
N/A | |
Completed |
NCT03412305 -
The Effect of Antibiotic Prophylaxis Associated With Dental Implant Surgery
|
Phase 4 | |
Not yet recruiting |
NCT01245829 -
A Randomized Trial Comparing Matt and Antimicrobial Cellomed Laminates
|
N/A | |
Not yet recruiting |
NCT03780114 -
Knowledge, Attitude and Practice Survey for Egyptian Dentists About Infection Control in Pediatric Dental Clinics
|
||
Completed |
NCT01481935 -
Enhanced Room Cleaning in Intensive Care Units to Reduce Gown and Glove Contamination With Multi-drug-resistant Bacteria
|
N/A |