Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT05093244
Other study ID # BIS-CL-5001
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Start date February 10, 2023
Est. completion date February 10, 2023

Study information

Verified date February 2023
Source B. Braun Medical Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The objective of this study is to establish reasonable assurance of safety and effectiveness to support an FDA premarket approval (PMA) application for the SeQuent® Please ReX™ Drug Coated PTCA Balloon Catheter as indicated.


Description:

The investigation is a prospective, randomized, multi-center IDE study comparing the SeQuent Please ReX to plain old balloon angioplasty (POBA). The study will be conducted at up to 30 investigational sites and enroll up to 296 patients with in-stent restenosis of a metallic coronary stent who are suitable candidates for PTCA procedures. After consent and assessment of inclusion and exclusion criteria, eligible patients will be randomized to either the SeQuent Please ReX or POBA arm based on a 2:1 randomization ratio. Subjects will return for follow-up through 5 years.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date February 10, 2023
Est. primary completion date February 10, 2023
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility INCLUSION CRITERIA: 1. ISR (>50%) of a metallic coronary stent of any type (BMS or DES) 2. Symptomatic ischemic heart disease, including: - Chronic stable angina (and/or objective evidence of myocardial ischemia on functional study or fractional flow reserve [FFR] measurement) or - Acute coronary syndrome (unstable angina or non-ST-elevation myocardial infarction (NSTEMI)), who require elective or urgent percutaneous coronary intervention (PCI) 3. One or two ISR lesions requiring treatment - ISR lesions may be located in two different vessels - Additional non-ISR (de novo) lesions are permitted and may be located in the target or other vessels 4. Target lesion reference vessel diameter is =2.0 or =4.0 mm by visual estimation 5. Total lesion length less than or equal to 34 mm by visual estimation (to permit treatment with balloon up to 40 mm) 6. Male or female, age 18 years or older 7. Willing to provide written informed consent and written HIPAA authorization prior to initiation of study procedures 8. Willing to comply with the specified follow-up visits 9. Willing and able to comply with post-treatment medications (dual antiplatelet therapy (DAPT) followed by life-long aspirin) 10. Non-target lesions must be treated successfully (i.e., residual diameter stenosis <30% without complications) before proceeding to treatment of ISR lesion(s) EXCLUSION CRITERIA: 1. Target lesion has undergone more than two prior stent implant procedures, i.e., more than two layers of stent are present at any segment of target lesion 2. Presents with ST-elevation myocardial infarction (STEMI) 3. STEMI within the past 72 hours 4. Chronic kidney disease, defined as glomerular filtration rate (GFR) <15 ml/min/1.73m^2 on baseline labs 5. Thrombocytopenia, defined as a platelet count of <50,000 microL on baseline labs 6. Target lesion is a chronic total occlusion 7. Bleeding diathesis, coagulopathy, or contraindication to antiplatelet therapy 8. Target lesion restenosis is within a bio-resorbable scaffold 9. Target lesion is located within the left main 10. Pregnant (verified with a urine or blood pregnancy test), breast-feeding, or planning to become pregnant 11. Severely disabled and/or life expectancy appears limited (=12 months) according to the investigator's opinion 12. Known hypersensitivity to paclitaxel and/or resveratrol or any of the product ingredients 13. Currently participating in an investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints Note: Bifurcation lesions are not excluded; however, the main branch should be treated per randomization, and the side branch should be treated provisionally per current standard of care. Angiographic Exclusion Criteria: Subjects must not meet any of the following angiographic exclusion criteria after lesion preparation: 1. Dissection type C - F 2. TIMI < III 3. Residual stenosis >30%

Study Design


Related Conditions & MeSH terms


Intervention

Device:
SeQuent Please ReX
The SeQuent Please ReX is a conventional rapid exchange balloon tip catheter with a drug-coated balloon (DCB). The surface of the SeQuent Please ReX balloon is coated with paclitaxel, embedded in a soluble matrix (resveratrol).
Plain old balloon angioplasty (POBA)
Any commercially available semi-compliant PTCA balloon may be used per the investigator's discretion.

Locations

Country Name City State
n/a

Sponsors (3)

Lead Sponsor Collaborator
B. Braun Medical Inc. Bright Research Partners, Infraredx

Outcome

Type Measure Description Time frame Safety issue
Primary Freedom from target lesion failure (TLF) TLF is defined as the composite of any of the following events:
Clinically-driven target lesion revascularization (TLR)
Myocardial infarction (MI; not clearly attributable to a nontarget vessel)
Cardiovascular death
12 months post-procedure
Secondary Late lumen loss (LLL) Assessed on the first 100 subjects reaching 9-month follow-up (angiographic cohort). Minimum lumen diameter (MLD) assessed at follow-up angiography minus the MLD assessed immediately after the index procedure. MLDs are measured by qualitative comparative analysis. 9 months post-procedure
Secondary All death Death of subject. 12 months post-procedure and annually thereafter to study completion
Secondary Cardiovascular death Death resulting from cardiovascular causes. 12 months post-procedure and annually thereafter to study completion
Secondary Myocardial infarction (MI) Not clearly attributable to a nontarget vessel 12 months post-procedure and annually thereafter to study completion
Secondary Major adverse cardiac events (MACE) Defined as the composite of all death, clinically-driven TLR, and MI 12 months post-procedure and annually thereafter to study completion
Secondary Stent thrombosis Early, late, or very late; ARC category of definite or probable 12 months post-procedure and annually thereafter to study completion
Secondary Clinically-driven target lesion revascularization (TLR) Target lesion revascularization is defined as a repeat percutaneous intervention of the target lesion or bypass surgery of the target vessel performed for restenosis or other complication of the target lesion. 12 months post-procedure and annually thereafter to study completion
Secondary Clinically-driven target vessel revascularization (TVR) Target vessel revascularization is defined as any repeat percutaneous intervention or surgical bypass of any segment of the target vessel including the target lesion. 12 months post-procedure and annually thereafter to study completion
Secondary Device, lesion, and procedural success Device success defined as achievement of a final residual stenosis of =30% (as determined by the angiographic core lab), using the SeQuent Please ReX or control balloon. Lesion success defined as achievement of a final residual stenosis of =0% (as determined by the angiographic core lab), using any device. Procedural success defined as lesion success without the occurrence of major adverse events during the procedure, where "major adverse event" is considered to be an event without the occurrence of in-hospital MI, TVR, or cardiac death. Post-procedure (device and lesion success) and at discharge (procedural success)
See also
  Status Clinical Trial Phase
Completed NCT00341562 - Genomics of In-Stent Restenosis N/A
Completed NCT05509296 - Compare the Effectiveness and Safety of Two Different Kinds of Cutting Balloon in Coronary Artery Disease N/A
Not yet recruiting NCT06090890 - Anti-inflammatory Therapy for Recurrent In-stent Restenosis Phase 4
Active, not recruiting NCT00998439 - Treatment of Drug-eluting Stent (DES) In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheter Phase 2
Active, not recruiting NCT05731700 - CVT-ISR First in Human Trial for Coronary In-Stent Restenosis N/A
Completed NCT03260517 - The PREVAIL Study N/A
Not yet recruiting NCT03588962 - Metal Allergy In-Stent Restenosis Study N/A
Completed NCT00393315 - P E P C A D II, The Paclitaxel-Eluting PTCA-Balloon Catheter in Coronary Artery Disease to Treat In-Stent Restenoses Phase 2
Recruiting NCT03874481 - The Effect of Sleep Quality on Coronary Artery Disease and In Stent Restenosis
Active, not recruiting NCT01127958 - DARE-trial: A Trial Studying the Effect of the SeQuent Please Drug-eluting Balloon Compared to the Xience Prime Drug-eluting Stent for the Treatment of Stenosis of an Earlier Implanted Stent. N/A
Active, not recruiting NCT04647253 - A Clinical Trial to Assess the Agent Paclitaxel Coated PTCA Balloon Catheter for the Treatment of Subjects With In-Stent Restenosis (ISR) Phase 3
Active, not recruiting NCT03529006 - Absorb Bioresorbable Scaffold vs. Drug Coated Balloon for Treatment Of In-Stent-Restenosis N/A
Completed NCT00485030 - Diffuse Type In-Stent Restenosis After Drug-Eluting Stent Phase 4
Not yet recruiting NCT03809754 - Optical Coherence Tomography Guided Percutaneous Coronary Intervention for Drug-eluting In-stent Restenosis N/A
Completed NCT00916279 - PERVIDEO I Registry, The Lutonix Paclitaxel-Coated Balloon Catheter for the Treatment of Coronary In-Stent Restenosis Phase 1/Phase 2
Recruiting NCT05473884 - Lesion Preparation in Femoropopliteal Artery Occlusion Disease
Recruiting NCT01239940 - RIBS IV (Restenosis Intra-stent of Drug-eluting Stents: Paclitaxel-eluting Balloon vs Everolimus-eluting Stent) Phase 4
Active, not recruiting NCT01239953 - RIBS V (Restenosis Intra-stent of Bare Metal Stents: Paclitaxel-eluting Balloon vs Everolimus-eluting Stent) Phase 4
Not yet recruiting NCT06148441 - Role of Novel Biomarkers Associated With In-stent Restenosis After Percutaneous Coronary Intervention
Completed NCT05512832 - In-stent Restenosis and Pericoronary Fat Attenuation Index