View clinical trials related to Implant Complication.
Filter by:The current trial aim was to evaluate clinically and radiographically the changes around dental implants inserted immediately in maxillary anterior esthetic zone using a novel combination of autogenous whole tooth graft (AWTG) with socket shield approach (SSA) and compared this approach to socket shield technique with xenograft. The present study included 63 patients, aged 20 to 45, with teeth that needed to be extracted. After Kafrelsheikh University research ethics committee approval, patients were randomized into 3 groups: group I patients underwent immediate implantation using socket shield protocol, while group II patients underwent the same procedure, but the shield/fixture jumping gap was grafted by xenograft. finally group III was grafted by AWTG that was created using the decoronated crown and the extracted palatal portion of the tooth; and then placed in the peri-implant gap defect.
Reporting of the reason for implant removal in a hospital setting over 20 years. retrospective design.
This clinical study was done to compare between digital with conventional impression used in the CAD/CAM constructed 4- implant supported mandibular overdenture base regarding their effect on the bone height changes
This study aims to evaluate retention ,chewing efficiency and masticatory performance of flexible versus CAD/CAM partial dentures opposing to fixed implant retained restorations.
Thirty maxillary edentulous patients with previous mandibular All-on-4 screw retained prosthesis and their age ranged from 55 to 65 years were selected from the outpatient clinic, of prosthodontics Department, Faculty of Dentistry, Mansoura University from March 2022 to July2022 and 80% power was used to calculate patients sample according to the results of a previous study 1 which showed no significant difference was reported when comparing occlusal stability ,implant stability and periimplant soft tissue changes between different implants angulation of both groups. (Effect size=.70mm and α=.05). The power analysis was performed using the G*Power program (version 3.1.5, Kiel, Germany)
The study aims to compare implant stabilities between immediate and early loaded, immediately placed bone-level tapered dental implants in the upper jaw in the partial and total edentulous patients assessing marginal bone loss, oral health-related quality of life, and patient satisfaction within one, two and five years of follow-ups.
Objectives: evaluate the success rate, prosthetic maintenance , clinical and radiologic results of vertical implants with straight abutments versus inclined implants with angled abutments to retain locator maxillary overdentures. There were two groups : 1) The control group 2) The study group
Few previous studies have employed HA in the implant socket; instead, the majority have applied it topically to the area around dental implants after they have been placed. The application was done after suturing in these investigations. Therefore, the goal of the current study was to inject HA into the implant socket and onto the alveolar bone prior to implant insertion and suturing in order to preserve the HA for an extended period of time. This study aims to use a visual analog scale (VAS) on the first, third, and tenth days following the surgical intervention to assess the efficacy of employing HA in dental implants in terms of pain reduction that may accompany dental implant surgery.
complications of implant retained prostheses
dental implants are usually placed by sequential set of drills which could increase the time of the surgery and could raise the temperature of the osteotomy preparation so a new drill was designed to place the implants fast and easy way