The validity and reliability of adduction angle measurement of hip with smartphone will be
investigate.
Description:
Our study is to investigate the intra-rater reliability, inter-rater reliability and
concurrent validity of iPhone Measurement Applications to measure iliotibial band length in
individuals without iliotibial band-related pathology. The aim of this study is to evaluate
the intra-rater reliability, inter-rater reliability and concurrent validity of bubble
inclinometer and iPhone Measurement Applications in the evaluation of iliotibial band tension
in healthy individuals. This research is being done to determine if there are other more
reliable, valid or innovative technological ways to measure iliotibial band length.
Participants:
A priori power analysis indicated that a minimum 16 or more participants should be enrolled
the study for a correlation of 0.7, with an α level of .05 and power of 95%. The study
protocol comply with the Declaration of Helsinki for Human Experimentation. Participants were
excluded if they had hip or knee surgery in the past year and iliotibial band syndrome. All
participants provide written informed consent. Permission for the study was obtained from KTO
Karatay University Faculty of Medicine Drug and Non-Medical Device Research Ethics Committee
with decision number 2019/012.
Two experienced physiotherapists will evaluate the elasticity of both the dominant and
non-dominant iliotibial bands after 2 minutes of warm-up before the evaluation. Measurements
will be made by two physical therapists for each participant in different rooms without
seeing each other. The examiners will carry out three measurements for both extremities,
using both the bubble inclinometer and the iPhone® measurement app. A 5-minute passive rest
will be give between measurements. All evaluations will be first conducted by Examiner 1 and
then by Examiner 2. Measurement values will be record by a third physiotherapist. Data
obtained from both devices will be compare in terms of validity and reliability using
statistical analysis used in previous studies.
All inclinometric measurements will be do by two independent blind examiners (B.S.U. and
H.G.) and the range of motion (ROM) will be read directly from the devices by a third
examiner.
Before the first measurement, the participant will be ask to warm up for five minutes. For
the measurement, the participant will be ask to lie on his side and flex the knee to 90
degrees. The examiner will stabilize the patient from the pelvis with one hand, and with the
other hand brought the flexed leg of the participant to abduction and extension. The Examiner
3 will be record the result by placing the device to be measured on the lateral projection of
the midpoint of the femur. By preserving the participant's position, measurements will be
make with the other device immediately and the values will bw record by the Examiner3.
After the first measurement, second and third measurements will be take at 2-minute passive
intervals.
After the participants will complete their first examiner evaluation, they will move to the
second examiner's room. The same protocol will be use for all measurements by the Examiner 2.
Instruments We will use 2 devices to measure iliotibial band length; bubble inclinometer
(Baseline, Fabrication Enterprises Inc., New York) and iPhone® Measurement Applications
(Apple Inc, California). The iPhone® Measurement Applications measurements will make with the
iPhone 6s plus running IOS 13.3.1 (Apple Inc, California).