NCT ID: NCT06012123 Completed - Clinical trials for Iliac Artery Stenosis

BS-CERAB TECHNIQUE

BS-CERAB
Start date: January 1, 2023
Phase:
Study type: Observational [Patient Registry]

The covered endovascular reconstruction of aortic bifurcation (CERAB) technique was described l in 2013 to reconstruct the aortic bifurcation in a more anatomical and physiological way. With the use of this technique, a covered stent is expanded 15 to 20 mm above the aortic bifurcation and this stent is proximally adapted to the aortic wall with a larger balloon, thereby creating a cone-shaped stent. Two iliac covered stents are then placed in the distal conic segment and simultaneously inflated, making a tight connection with the aortic stent, as if they were molded together, thus simulating a new bifurcation. This minimal invasive endovascular technique using covered stents, was developed in order to optimize endovascular mimicking the anatomical configuration of the aortic bifurcation and in an attempt to overcome the disadvantages of kissing stents influenced by geometric factors such as radial mismatch, protrusion mismatch and stent conformation. The use of BeGraft (balloon-expandalbe covered stent) and Solaris (self-expandable covered stent) fro this technique is revised.

NCT ID: NCT04343196 Completed - Clinical trials for Peripheral Arterial Disease

Digital Variance Angiography in Diagnostic Angiographies for Effective Radiation Dose Reduction

Start date: April 21, 2020
Phase: N/A
Study type: Interventional

Digital Variance Angiography (DVA) is a new tool in medical imaging with proven image quality reserve. The previously observed quality reserve of Digital Variance Angiography (DVA) in lower extremity angiographies, allowed to lower radiation exposure by 70 % during DSA in lower extremity diagnostic angiographies with non-inferior image quality. The aim of this study is to apply this non-inferior image quality and use it for radiation exposure reduction in diagnostic lower limb angiography. The project would prospectively block-randomise (50:50) patients, who undergo elective diagnostic angiography into two groups: a comparator group examined by means of conventional DSA using a standard care protocol (Siemens Artis Zee, Extremities Care setting, 1.2 µGy/frame) (Group B) and a study group examined by means of DVA using a low-dose protocol (0.36 µGy/frame corresponding to 70% decrease of radiation dose) (Group A). During each procedure the investigators record radiation exposure (cumulative dosage, dose area product) and contrast media usage and procedural time then compare the results of the groups. Qualitative image review is done to compare conventional DSA and reduced radiation exposure DVA images after image acquisition. Our hypothesis is that with the previously proven non-inferior image quality, the investigators will be able to reduce radiation exposure of the participants and also staff members in everyday clinical practice.

NCT ID: NCT03844724 Completed - Clinical trials for Peripheral Arterial Disease

Drug-eluting PTA Balloon Dilatation Catheter in the Treatment of Peripheral Artery Stenosis or Occlusion

Start date: April 10, 2015
Phase: N/A
Study type: Interventional

Clinical study on safety and efficacy of ZENFlow™ drug-eluting PTA balloon dilatation catheter in the treatment of iliac, femoral and popliteal artery stenosis or occlusion

NCT ID: NCT00896337 Completed - Clinical trials for Iliac Artery Stenosis

EPIC Nitinol Stent System in the Treatment of Atherosclerotic Lesions in Iliac Arteries

ORION
Start date: May 2009
Phase: Phase 3
Study type: Interventional

The ORION study is being conducted to determine whether the Epic™ Nitinol Stent for primary stenting of iliac atherosclerotic lesions shows acceptable performance at 9 months.