Clinical Trials Logo

Clinical Trial Summary

Aorto-iliac aneurysms with involvement of the iliac bifurcation or hypogastric artery aneurysms constitute only 20% of all aneurysmal pathology of the abdominal aorta. As it is a rare pathology, in order to carry out a comprehensive study of the results, it is necessary to carry out multicenter studies to collect a considerable number of cases.

One of the most widely used devices worldwide is the GORE® EXCLUDER® Iliac Branch Endoprosthesis, CE marked since 2013, this stent consists of two components: the iliac branch stent and the hypogastric component (HGB), for its joint use there are instructions for use in relation to the anatomical characteristics of the patient in order to be used.

Currently, there are other devices that can be used as a hypogastric component when the patient's anatomy does not allow the use of HGB, one of them is: GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis, CE marked since 2017.

This study is designed to evaluate the efficacy and safety of devices with iliac branches for the treatment of aorto-iliac aneurysms that affect the bifurcation of common iliacs, with the use of these devices, as well as to determine the quality of life of patients after their implantation.


Clinical Trial Description

This is a multicenter study in which 10 to 15 hospitals will participate. It is a non-intervention study in which the data from the medical records of the patients will be collected according to the action protocols of each center.

This is a prospective, non-randomized study where the data of the implants performed during a 12-month period will be recorded. Both the diagnosis and the follow-up of the patients to whom the device is implanted will strictly adhere to the protocols present in each center and which are the ones used according to all current clinical guidelines. At no time will any intervention or diagnostic test be performed outside the protocols in force in each center. The study does not imply any intervention or visit for the participants that is not routine clinical practice according to the clinical-healthcare procedures of each participating center.

Following routine clinical evaluations performed as part of standard patient care, it will be decided, after obtaining informed consent from patients, and whether they are eligible for the study and scheduled for the implant procedure with the devices. of the study.

After a baseline evaluation, the implant will be performed according to the usual clinical practice of each participating center. A follow-up visit will be made 30 days, 6 and 12 months after the procedure.

Investigators will perform implant and device evaluations and document adverse events (AE) and possible device deficiencies

Study objectives

1. Primary Objectives 1.1. General safety and efficacy at 6 months post-implant

Defined as :

- Absence of symptoms or rupture of the aneurysm.

- Growth of the aneurysm.

- Absence of reintervention.

- Need for conversion to open surgery.

- Significant clinical migration.

- Branch occlusions.

1.2 Technical success: GORE® Excluder® IBE implant in the planned location. No conversion, death, type I or III endoleaks or obstruction of the extremity of the graft.

1.3. Safety and efficacy of IBE together with VBX compared to IBE all-in-one system at 6 months.

2 Secondary objectives 2.1. Absence of major adverse effects defined as:

- Absence of morbidity and / or mortality related to the aneurysm or the device.

- Absence of mortality from any cause.

2.2. Assessment of quality of life based on the EuroQol 5D questionnaire ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04356313
Study type Observational
Source Asociacion para el Estudio de la Enfermedades Vasculares de Galicia
Contact Jorge Fernández Noya, M.D
Phone +34629550241
Email jfernoy@gmail.com
Status Recruiting
Phase
Start date October 1, 2019
Completion date December 31, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Enrolling by invitation NCT04035356 - HAART Annuloplasty Device Valve Repair Registry
Recruiting NCT02729064 - Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose Phase 1
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Completed NCT02283307 - Dual Energy CT Urography With Reduced Iodinated Contrast N/A
Completed NCT01678261 - X-chromosome Inactivation, Epigenetics and the Transcriptome N/A
Terminated NCT01055275 - Cook Iliac Branch Graft Post-market Registry N/A
Completed NCT00615888 - Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair N/A
Completed NCT03510793 - Microcirculation and Anesthesia in Vascular Surgery
Completed NCT03207568 - RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU) N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT01918969 - Reference Values of Circulating Endothelial Progenitor Cells N/A
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Not yet recruiting NCT01918982 - Circulating Endothelial Progenitor Cells and Aortic Aneurysm N/A
Completed NCT01256372 - An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery Phase 2
Recruiting NCT00661518 - PET/CT Imaging of Aneurysm Wall Inflammation N/A
Completed NCT00094575 - Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA) Phase 4
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Recruiting NCT05603520 - Phenotyping Heterogeneity and Regionality of the Aorta
Completed NCT03727542 - Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels N/A