Clinical Trials Logo

Clinical Trial Summary

Right ventricular pacing causes ventricular dyssynchrony and may be associated with impaired outcome. In the last decade, several approaches for more physiological pacing became available and were implemented in the latest guidelines. However, compared to conventional device implantation, cardiac resynchronization, His bundle pacing and left bundle area pacing remain demanding procedures in the individual case. Goal of the single center observational "Pace conduct" study is to evaluate implantation success, safety and outcome of pacing methods that maintain physiologic ventricular activation.


Clinical Trial Description

Background: Conventional ectopic myocardial right ventricular pacing (RVP) causes ventricular dyssynchrony and may be associated with reverse ventricular remodeling, reduced ejection fraction (EF), left ventricular dilatation, functional mitral valve regurgitation, heart failure and an increased rate of new onset atrial fibrillation. Dependent on individual patient's characteristics, several strategies are established to prevent and to overcome the potential drawbacks of chronic RVP. In general, unnecessary ectopic RVP should be avoided. For example, in patients with sinus node disease and intact atrioventricular (AV) conduction, atrial pacing, AV (search) hysteresis or AAI-DDD/ADI pacing may be used. In patients with impaired cardiac function and an expected higher percentage of RVP, pacing strategies for cardiac resynchronization are indicated. Conventional cardiac resynchronization therapy (CRT) uses an additional transvenous left ventricular lead for synchronous ventricular stimulation and was shown to shorten QRS duration and to reduce morbidity and mortality in patients with chronic heart failure, left bundle branch block (LBBB) and reduced EF. Due to the non-physiological left ventricular epicardial stimulation, however, conventional CRT is associated with 30% of non-responders and may even prolong ventricular activation in patients with narrower QRS complex. First described in 1968, His bundle pacing (HBP) has evolved to an increasingly used alternative for cardiac pacing. Currently, HBP is regarded the most physiologic approach for ventricular stimulation because it prevents ventricular dyssynchrony and its potential fatal long-term consequences by preserving normal electrical activation of the ventricles. Clinical benefit of HBP has been shown compared with conventional permanent RVP and CRT. Recent studies documented restoration of normal electrical and mechanical left ventricular synchrony for both selective and non-selective HBP. However, compared with conventional RVP the implantation procedure for HBP is much more demanding requiring exact placement of the pacing lead within the anatomically variable His bundle area. Alternatively, the correction of bundle branch conduction disorders has been demonstrated for left bundle branch area (LBBA) pacing. As a consequence, current guidelines recommend pacing methods that maintain physiologic ventricular activation in patients with atrioventricular block who have an indication for permanent pacing with a LVEF between 36% and 50% and are expected to require ventricular pacing more than 40% of the time (class IIa indication). In summary, there is increasing evidence showing the benefits of the different strategies for physiologic pacing but the appropriate use of these approaches may be challenging in the individual case. Therefore, appropriate patient selection, implantation approaches, device programming and follow-up require further intensive evaluation. Objective: Main goal of the study is to evaluate implantation success for pacing methods aiming to maintain physiologic ventricular activation. Procedural success is defined as stable lead positioning and effective pacing within the target area with an appropriate and stable pacing threshold. Secondary goals of the study are to document and to evaluate - procedural parameters (e.g. venous access, time needed for lead implant, procedural duration, radiation) and adverse events dependent on procedural approaches and patients characteristics, - performance of the implanted system (sensing, pacing thresholds) and clinical outcome during routine follow-up Study design: Single center, non-randomized, observational study, retrospective data analysis, on-going prospective patient enrollment, descriptive statistics. Center: Klinikum Fuerth (Dept. for Heart and Lung diseases, section for clinical electrophysiology) / Germany in cooperation with the Dept. of Cardiology of the University Erlangen / Germany and the University of Trieste / Italy. Patients and methods: Primary endpoint: Implantation success. Effective pacing and acceptable pacing threshold at the targeted lead position. Target for lead placement is the area with maximum delayed ventricular activation for transvenous CRT, the His bundle for selective or non-selective HBP and the right interventricular septum with left bundle branch capture for LBBA pacing, respectively. Target thresholds for the lead placed within the coronary sinus or at the intrinsic conduction system is <2.5 V @ 1 ms with a maximum acceptable threshold of <4.0 V @ 2 ms or <5 V @ 1 ms. Target for all other leads is <1 V @ 0.5 ms. Secondary endpoints: patient characteristics and association with outcome. Implantation success and outcome correlated with patient characteristics including electrocardiogram and echocardiographic parameter and procedure related techniques and parameter. Safety: radiation exposure, number and type of adverse events and adverse device related events. Follow-up: device function, interrogation, programming and clinical outcome as evaluated in routine follow-up, incl. ECG, echocardiography and parameter for assessment of heart failure. Subpopulations: managed ventricular pacing, His bundle pacing, LBB-area pacing, CRT. Implantation with or without electroanatomic mapping system. Inclusion criteria: Implantation of a pacemaker or ICD according to the current guidelines (Class I or IIa indication) aiming to avoid pacing induced dyssynchrony, e.g. managed ventricular pacing, His-bundle pacing, LBB-area pacing or conventional transvenous CRT. Age ≥ 18 years. Exclusion criteria: No given informed consent for the procedure. No follow up data available. Sample size: For the observational study, there is no pre-specified sample-size. Data from 200 patients and procedures are expected. Data security: Study related data are collected by the study investigators in an anonymous clinic-internal data-base that is password protected. All investigators have to provide valid GCP training. Risk estimation: The study is observational and descriptive with anonymized data collection and data analysis. Therefore, the study adds no risk to the study population. Ethics: The "Pace-Conduct" study has been approved by the responsible ethics committee of the Friedrich- Alexander University Erlangen, Germany (145_20 Bc) ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04416958
Study type Observational [Patient Registry]
Source Klinikum-Fuerth
Contact Dirk Bastian, MD
Phone +49 911 7580 1101
Email dirk.bastian@klinikum-fuerth.de
Status Recruiting
Phase
Start date January 1, 2018
Completion date December 2030

See also
  Status Clinical Trial Phase
Recruiting NCT05048602 - Drug-induced Brugada Syndrome Research Database
Completed NCT04055740 - Intravascular Ultrasound (IVUS) Imaging During Transvenous Lead Extraction N/A
Not yet recruiting NCT01430806 - Dronaderone to Prevent Recurrent Implantable Cardioverter Defibrillator (ICD) Shocks N/A
Completed NCT02877693 - A Post-market Clinical Evaluation of St. Jude Medicalâ„¢ MR Conditional ICD System on Patients Undergoing Magnetic Resonance Imaging N/A
Completed NCT00890461 - Reconstruction of 12-Lead Electrogram From Intracardiac Signals From Defibrillators During or After Implantation N/A
Completed NCT03366181 - Anti Arrhythmic Therapies and Sudden Cardiac Deaths
Completed NCT02713360 - Screening and Intervention Reducing Anxiety in Patients With Implanted Cardioverter Defibrillator (ICD) N/A
Completed NCT06068699 - Postcards to Improve Remote Monitoring Adherence Among Veterans N/A
Completed NCT01594112 - Ability of Home Monitoring® to Detect and Manage the Inappropriate Diagnoses in Implantable Cardioverter Defibrillators. N/A
Recruiting NCT03357926 - Prospective Database for Prediction of Atrial Fibrillation in Pacemaker and ICD Patients
Active, not recruiting NCT04590144 - Safety and Performance of INVICTA Ventricular DF4 LEADS With Active Fixation-(APOLLO) N/A
Active, not recruiting NCT05361681 - EMI and CIED: Is High Power Charging of Battery Electric Car Safe? N/A
Active, not recruiting NCT04505007 - Guideline-Directed Medical Therapy in Patients After Implantation of Implantable Cardioverter Defibrillators to Improve Long-Term Outcomes N/A
Active, not recruiting NCT04981496 - Novel ICD Arrhythmia Detection Algorithm
Completed NCT04014946 - Assessment of Risk Factors for Appropriate ICD (Implantable Cardioverter-defibrillator) Intervention in Patients With Ischemic Cardiomyopathy N/A
Completed NCT02693262 - Comparing Rate Response With CLS Versus Accelerometer ICD Settings in Heart Failure Patients With BIOTRONIK CRT-Ds N/A
Recruiting NCT05072119 - Monaldi Hospital Rhythm Registry
Completed NCT00652522 - Atrial Fibrillation Management in Congestive Heart Failure With Ablation N/A
Recruiting NCT05835791 - END - VT Cohort Study
Active, not recruiting NCT04284800 - Myocardial Injury in Patients With Cardiac Implantable Electronic Devices Undergoing Defibrillation Threshold Testing