View clinical trials related to Hypoxia.
Filter by:The goal of this study was to evaluate the accuracy of pulse oximeters over the range of 70-100% per ISO 80601-2-61:2019. Four devices were placed on each subject with two on each index finger at the base and two on each index finger at the fingertip. SpO2 measurements from these devices were compared to sampling of arterial blood during brief stable oxygen desaturation in healthy volunteers to evaluate the claimed range.
This study specifically aims to elucidate the effects of IEK on sleep and recuperation in hypoxia, after training in normoxia. These conditions are in line with the widely applied live-high train-low strategy. Moreover, blood and tissue oxygenation status, as well as cerebral blood flow and cognitive function will be assessed.
To study the effect of high flow nasal cannula in comparisons with nasoprong used intraoperatively in patients oxygenation status
The incidence of hypoxemia during gastrointestinal endoscopy sedation is high, but there is still a lack of perfect prediction model of hypoxemia, which often leads to unpredictable respiratory complications. In order to ensure the safety of gastrointestinal endoscopy sedation and make emergency plans in advance, a better diagnostic model is urgently needed to help assess the risk of hypoxemia in patients undergoing the process and make early intervention measures. Facial photography is a simple and feasible measure that can show the facial soft tissue and structure of bone. The purpose of this study is to explore whether facial photography combined with other clinical indicators can build a prediction model of hypoxemia during gastrointestinal endoscopy sedation.
The aim of this study is to describe the effect of the Inogen Rove 6 Portable Oxygen Concentrator on peripheral oxygen saturation in adults receiving supplemental oxygen at night and examine whether the device can adequately maintain oxygen saturation during sleep.
This prospective, blinded observational clinical study was aimed to determine the effect of hyperhydration and muscle loss measured by Bioelectrical impedance vector analysis (BIVA) on mortality. The aim was to compare hydratation parameters measured by BIVA: OHY, Extracellular Water (ECW) / Total Body Wate (TBW) and quadrant, vector length, phase angle (PA) with cumulative fluid balance (CFB) recording (input-output) in their ability in predicting mortality as the abilities of the prognostic markers PA (BIVA), Acute Physiology and Chronic Health Evaluation II (APACHE II - score) and presepsin (serum Cluster of Differentiation (CD) 14-ST). The investigators also compared BIVA nutritional indicators (SMM, fat) with BMI and laboratory parameters (albumin, prealbumin and C-reactive protein (CRP) inflammation parameters) in the prediction of mortality. An important goal was to evaluate the usability of the BIVA method in critically ill patients on extracorporeal circulation, to compare the impedance data of the extracorporeal membrane oxygenation (ECMO) and non-ECMO groups.
Goal of our study is to investigate whether the implication of nasal positive airway pressure (nPAP) system on patients with high periprocedural risk could significantly lower the incidence of severe hypoxia and hypercarbia. Furthermore, we have set up goals to assess key components and factors, which lead to development of hypercarbia during endoscopy.
The aim of the current study was to examine the effects of 3-session repeated sprint training performed in a normobaric hypoxic condition with 48-hour rest intervals on sprint performance indices, arterial oxygen saturation (SpO2) and rating of perceived exertion (RPE) scores. Twenty-four moderately-trained males participated in this study voluntarily basis. This study was conducted on single-blind placebo-controlled design. Participants were divided into three groups as follows; normobaric hypoxia (3420 m; HYP), normobaric normoxia (162 m; PLA) and control group (CON). HYP and PLA groups subjected to 3 repeated sprint training session (4 set x 5 x 5 s sprints with 30 s recovery and 5 min rest between the sets) in normobaric hypoxia or normoxia condition. Pre- and pos-test were conducted 72 hours before and after the training intervention period. All the training and testing sessions performed in cycle ergometer. There were no detected significant time and condition interaction in the variables; relative peak power output (PPO), mean power output (MPO), percentage of sprint decrement score (Sdec%) and RPE observed in the scope of pre- and post-test.
The goal of this study was to evaluate the accuracy of pulse oximeters over the range of 70-100%. Two devices were placed on each subject with one on the finger and the other on the fingertip. SpO2 measurements from these devices were compared to sampling of arterial blood during brief stable oxygen desaturation in healthy volunteers to evaluate the claimed range.
The purpose of the study is to determine the effect of a single exposure of intermittent hypoxia on erythropoietin levels and hemoglobin mass in young adults, older adults and patients with type 2 diabetes.