Clinical Trial Summary

The purpose of this research study is to evaluate the Owlet Smart Sock 3 wireless pulse oximeter performance in assessing the heart rate and oxygen saturation in neonatal population, while measuring the same parameter with a standard wired pulse oximeter simultaneously. The monitoring duration with the study device will be a maximum of 60 minutes, after which the recorded data from the Owlet Smart Sock 3 and the standard wired pulse oximeters will be de-identified and analyzed.


Clinical Trial Description

This prospective observational study compared the HR and SpO2 measurements of the OSS3 (Owlet, Utah, USA) with the Masimo SET® (Masimo Corporation, California, USA) in infants admitted to the University of Utah NICU. The inclusion criteria were infants who weighed 1.7-2.5 kg at the time of monitoring and were medically stable to tolerate routine care. The exclusion criteria were: infants with significant anomalies, congenital deformities, or medical instability. Infants with an intravenous catheter (IV) and skin lesions on either foot were excluded from the study. The wireless device being tested was the OSS3. The gold standard for validating the pulse oximeter's accuracy is arterial blood oxygen saturation (SaO 2 ) at the pulse oximeter sensor site. [6] However, obtaining SaO2 is an invasive arterial blood test for infants. To avoid this conflict, the OSS3 was tested against the reference FDA-approved wired pulse oximeter Masimo. The study was approved by the University of Utah Institutional Review Board, and informed consent was obtained from parents. During the measurement, OSS3 and Masimo were placed on the infants with one device on each foot. Since the data obtained from the study devices can not be recorded in the hospital electronic medical record, the hospital wired pulse oximeter (Philips, Amsterdam, Netherlands) continued to be used on one of the infant's hands during the study period. OSS3 and Masimo were calibrated appropriately against the hospital wired pulse oximeter with matching HR and SpO 2 readings. Pulse oximetry data were collected simultaneously for 60 minutes on the quiet infants. The two devices (OSS3 and Masimo) continuously recorded HR (beats per minute, bpm) and SpO2 (%) every two seconds. Data from the 2 devices were uploaded and compared according to their time stamped measurements. The paired data agreement was compared using Pearson's correlation coefficient (r), Bland-Altman, Average Root Mean Square (ARMS), and Prevalence and Bias Adjusted Kappa (PABAK) analyses. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05635513
Study type Observational
Source Owlet Baby Care, Inc.
Contact
Status Completed
Phase
Start date July 14, 2021
Completion date December 3, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT04413097 - Delayed Cord Clamping With Oxygen In Extremely Low Gestation Infants N/A
Not yet recruiting NCT05514665 - Functional Imaging of Baby Brains
Completed NCT04184245 - Hemodynamic Responses to Cardio-respiratory Events in Preterm Infants
Completed NCT04249193 - Pulse Oximetry Measurement and Transfusions
Recruiting NCT03352310 - Feasibility and Safety of Umbilical Cord Blood Transfusion in the Treatment of Neonatal Cerebral Ischemia and Anemia Phase 1
Not yet recruiting NCT04528030 - A UK Interventional Trial in Premature Infants With Apnea of Prematurity Using a Simple, Non-invasive Vibratory Device to Study the Effectiveness in Supporting Breathing and General Stability N/A