Hypotension Clinical Trial
Official title:
Perfusion Index as a Predictor of Hypotension Following Sub-arachnoid Block Among Patients Undergoing Lower Segment Caesarean Section
C-section is one of the commonly performed surgical procedures. During this surgical procedure the surgeon cuts into uterine cavity through abdominal wall and takes out the baby. This is done by by making the lower half body of the patient numb by injecting local anesthesia drugs into the space surrounding the spinal cord. This allows the mother to remain awake and immediately bond with the baby once it gets delivered. Also this technique provides effective pain relief both during and after the surgery. However like any other technique or drug it is associated with a number of side effects. The most important being fall in blood pressure. There are numerous ways to treat it. However if one is able to predict fall in blood pressure before administration of anesthetic technique one can easily prevent it. One of the recently discovered novel way to predict fall in blood pressure is Perfusion index which is calculated by Pulse oximeter. It is a device use to check amount of oxygen in blood and heart rate. Perfusion index refers to the total amount of blood present in the limbs of the person. Once we administer drug in the space surrounding the spinal cord the amount of blood in the limbs increases while the amount returning to heart decreases which ultimately results in less amount of blood being pumped out by heart resulting in fall in blood pressure. Therefore theoretically those individuals who have a high baseline Perfusion index will more likely to develop low blood pressure. This study aims to identify the cut off value of perfusion index to predict fall in blood pressure.
Spinal anesthesia is employed to provide excellent surgical conditions in case of C-Section. It is the anesthetic technique of choice among obstetric patients. However it is associated with sympathectomy which reduces the venous return and ultimately causes hypotension. This hypotension is mainly due to redistribution of blood volume to the peripheral compartment. Perfusion index which is measured by Pulse Oximetery is a ratio of pulsatile to non-pulsatile blood in the peripheral compartment of the body. As spinal anesthesia causes sympathectomy, peripheral blood volume increases. As a result perfusion index value should rise. This will then co-relate with hypotension. In simple terms those individuals who have a high baseline Perfusion index value will more likely to develop hypotension. This study aims to identify the baseline perfusion index value which co-relates with development of hypotension following sub-arachnoid block for C-section. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04062994 -
A Clinical Decision Support Trial to Reduce Intraoperative Hypotension
|
||
Active, not recruiting |
NCT02016599 -
Effects of Transitional Circulation in ELBW Infants
|
||
Recruiting |
NCT05836610 -
Hydrocortisone Therapy Optimization During Hypothermia Treatment in Asphyxiated Neonates
|
Phase 4 | |
Suspended |
NCT02315937 -
Hemodynamic Assessment During Spinal Anesthesia Using Transthoracic Echocardiography'
|
N/A | |
Completed |
NCT02907931 -
Carotid Doppler Ultrasound for the Measurement of Intravascular Volume Status
|
N/A | |
Completed |
NCT03215797 -
Phenylephrine or Norepinephrine for a Better Hemodynamic Stability
|
Phase 3 | |
Recruiting |
NCT02532270 -
Detecting Hypotension By Continuous Non-invasive Arterial Pressure Monitoring
|
N/A | |
Completed |
NCT02437799 -
Dicrotic Notch and Hypotension at Caesarean Under Spinal Anaesthesia
|
N/A | |
Completed |
NCT02802683 -
Hemodynamic Impact of Hyperbaric Versus Isobaric for Spinal Anesthesia During Cesarean Delivery
|
Phase 4 | |
Not yet recruiting |
NCT01941472 -
Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness
|
N/A | |
Completed |
NCT01930227 -
Transcutaneous Electrical Acupoint Stimulation(TEAS) for Hypotension After Spinal Anesthesia in Parturients
|
N/A | |
Completed |
NCT02146898 -
The Severity Of Hypotension Comparing Three Positions During Spinal Anesthesia For Cesarean Delivery
|
N/A | |
Recruiting |
NCT01434251 -
Treatment of Hypotension of Prematurity (TOHOP)
|
N/A | |
Completed |
NCT01592669 -
Passive Leg Raising Attenuates and Delays Tourniquet Deflation-induced Hypotension and Tachycardia
|
N/A | |
Withdrawn |
NCT01183741 -
Accuracy of Non-Invasive Blood Pressure Measurement in Adults
|
Phase 3 | |
Completed |
NCT00991627 -
Different Approaches to Maternal Hypotension During Cesarean Section
|
Phase 4 | |
Withdrawn |
NCT00750516 -
Lactic Acid Levels In Hypotensive Patients Without(Standard) and With Tourniquet
|
||
Completed |
NCT00115726 -
Trial Assessing the Effect of Preoperative Furosemide on Intraoperative Blood Pressure
|
Phase 4 | |
Recruiting |
NCT05513066 -
Management Arterial Hypotension During Planned Caesarean Section, Intravenous Ephedrine/Phenylephrine Mixture Versus Intravenous Baby Noradrenaline
|
||
Completed |
NCT04089644 -
Manual vs Closed-loop Control of Mean Arterial Pressure
|
N/A |