Clinical Trials Logo

Clinical Trial Summary

Undifferentiated hypotension is a medical emergency where a patient's blood pressure drops to critical levels due to several possible reasons. The medical staff treating the patient will need to find out the reason for your drop in blood pressure as soon as possible. When treating low blood pressure, the medical staff typically performs a procedure called central venous cannulation (CVC). CVC involves accessing a large vein (usually the subclavian under the collarbone) by inserting a needle into the vein. By doing this, the medical staff can measure the pressures in the patient's veins or give medicine to the patient while they are in the hospital. The purpose of this study is to compare the time needed to complete CVC using the AxoTrack device to CVC guided by landmarks on a patient's body. The investigators expect that there will be a maximum of 30 patients enrolled in this study.


Clinical Trial Description

Central venous cannulation (CVC) is commonly performed to give volume resuscitation and parenteral medications to patients with time sensitive conditions such as severe traumatic injury or undifferentiated shock. CVC via the subclavian route is associated with more frequent technical complications but less frequent infection or thrombosis as compared with via the internal jugular or femoral veins. Traditionally CVC via the subclavian vein is guided by anatomical landmarks. CVC guided by real-time use of traditional diagnostic ultrasound device is associated with a lower technical failure rate (overall and on first attempt), fewer punctures, faster access, and fewer mechanical complications as compared with guidance by anatomical landmarks when performed via the internal jugular vein. It remains unclear whether CVC guided by real-time ultrasound is associated with significantly lower failure and complication rates as compared with CVC guided by landmarks when performed via the subclavian vein. CVC guided by real-time ultrasound may reduce the incidence of complications, number of punctures, and the time between skin penetration and the aspiration of venous blood into the syringe as compared with guidance by landmarks. A limitation of guidance by a traditional diagnostic ultrasound device is it that it may require an assistant to perform, which may not be feasible when treating time sensitive conditions or in low resource settings. In addition, most traditional ultrasound probes are not designed to image the subclavian vein behind the clavicle. The AxoTrack system is a novel ultrasound guidance system recently cleared for human use by the United States Food and Drug Administration. It is intended to facilitate CVC by a single operator as well as to reduce complications and time associated with CVC. The AxoTrack has a small ultrasound scan head which facilitates imaging of the subclavian vein. It remains unclear whether CVC guided by AxoTrack reduces procedure times and complication rates when compared with CVC using landmark guidance in patients with undifferentiated hypotension. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03027323
Study type Interventional
Source University of Washington
Contact
Status Withdrawn
Phase N/A
Start date February 10, 2017
Completion date December 2020

See also
  Status Clinical Trial Phase
Completed NCT04062994 - A Clinical Decision Support Trial to Reduce Intraoperative Hypotension
Active, not recruiting NCT02016599 - Effects of Transitional Circulation in ELBW Infants
Recruiting NCT05836610 - Hydrocortisone Therapy Optimization During Hypothermia Treatment in Asphyxiated Neonates Phase 4
Completed NCT03215797 - Phenylephrine or Norepinephrine for a Better Hemodynamic Stability Phase 3
Suspended NCT02315937 - Hemodynamic Assessment During Spinal Anesthesia Using Transthoracic Echocardiography' N/A
Completed NCT02907931 - Carotid Doppler Ultrasound for the Measurement of Intravascular Volume Status N/A
Recruiting NCT02532270 - Detecting Hypotension By Continuous Non-invasive Arterial Pressure Monitoring N/A
Completed NCT02802683 - Hemodynamic Impact of Hyperbaric Versus Isobaric for Spinal Anesthesia During Cesarean Delivery Phase 4
Completed NCT02437799 - Dicrotic Notch and Hypotension at Caesarean Under Spinal Anaesthesia N/A
Not yet recruiting NCT01941472 - Transcutaneous pO2, Transcutaneous pCO2 and Central Venous pO2 Variations to Predict Fluid Responsiveness N/A
Completed NCT02146898 - The Severity Of Hypotension Comparing Three Positions During Spinal Anesthesia For Cesarean Delivery N/A
Completed NCT01930227 - Transcutaneous Electrical Acupoint Stimulation(TEAS) for Hypotension After Spinal Anesthesia in Parturients N/A
Recruiting NCT01434251 - Treatment of Hypotension of Prematurity (TOHOP) N/A
Withdrawn NCT01183741 - Accuracy of Non-Invasive Blood Pressure Measurement in Adults Phase 3
Completed NCT01592669 - Passive Leg Raising Attenuates and Delays Tourniquet Deflation-induced Hypotension and Tachycardia N/A
Completed NCT00991627 - Different Approaches to Maternal Hypotension During Cesarean Section Phase 4
Withdrawn NCT00750516 - Lactic Acid Levels In Hypotensive Patients Without(Standard) and With Tourniquet
Completed NCT00115726 - Trial Assessing the Effect of Preoperative Furosemide on Intraoperative Blood Pressure Phase 4
Recruiting NCT05513066 - Management Arterial Hypotension During Planned Caesarean Section, Intravenous Ephedrine/Phenylephrine Mixture Versus Intravenous Baby Noradrenaline
Completed NCT04089644 - Manual vs Closed-loop Control of Mean Arterial Pressure N/A