Clinical Trials Logo

Clinical Trial Summary

This is a feasibility and clinical evaluation study of the VisuMax femtosecond laser for refractive correction of hyperopia using the small incision lenticule extraction (ReLEx smile) method.

In ReLEx® the VisuMax femtosecond laser creates two interfaces that define a refractive lenticule of stromal tissue. In ReLEx® FLEx, the upper interface is converted into a LASIK flap by the creation of a sidecut. The LASIK flap is lifted and the lenticule can be removed to correct the refractive error by tissue subtraction. In ReLEx® smile, the lenticule is dissected and removed through a small 2-3mm incision without the need to create a whole flap.

The aims are i) to optimize the VisuMax settings for lenticule separation ii) to optimize the lenticule geometry iii) to assess the safety, efficacy and stability of the treatment


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT02316041
Study type Interventional
Source Tilganga Institute of Ophthalmology
Contact Kishore R Pradhan, MD
Phone 009779803397021
Email drkishoreraj@hotmail.com
Status Recruiting
Phase N/A
Start date January 2014

See also
  Status Clinical Trial Phase
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Completed NCT02423109 - Bilateral Dispensing Study of Fanfilcon A Toric Versus Enfilcon A Toric Lenses N/A
Completed NCT01392950 - Clinical Study of Clariti Monthly Contact Lens N/A
Withdrawn NCT00765960 - Evaluation of Outcomes Using the Amo Advanced CustomVue Ilasik Procedure
Completed NCT00520689 - Multipurpose Disinfecting Solution Compatibility With a Silicone Hydrogel Contact Lens Phase 3
Completed NCT05538182 - Zimbabwe Eyecare And Learning(ZEAL):Formative Research on Hyperopia and Educational Outcomes in Primary School Children N/A
Enrolling by invitation NCT05976750 - Air Optix® Night and Day® Aqua Daily Wear
Completed NCT02575911 - Accuracy of LASIK Flaps Created With the LenSx® Femtosecond Laser - A Pilot Study N/A
Completed NCT05735990 - Retrospective Clinical Investigation of the Safety and Performance of 640PM Trifocal IOL Implantation in Patients With Cataract and/or Ametropia (Hyperopia, Myopia) and/or Presbyopia
Withdrawn NCT03671096 - Safety and Efficacy of the Transform™ Corneal Allograft for Hyperopia Correction N/A
Recruiting NCT02279446 - Development of a Validated Chart for Intermediate Vision Assessment N/A
Completed NCT01951573 - Evaluation of a New Daily Disposable Multifocal Contact Lens Design N/A
Completed NCT02060539 - Multicenter Dispensing Study of Biofinity Lenses in Extended Range N/A
Completed NCT01467557 - Daily Disposable Performance of 1•DAY ACUVUE® TruEye™ and 1•DAY ACUVUE® MOIST® With LACREON® TECHNOLOGY
Completed NCT01228591 - Pilot Dispensing Evaluation of a Plus Power Lens N/A
Completed NCT03722784 - Evaluation of Silicone Hydrogel Daily Wear Contact Lenses for Up to One (1) Month of Daily Wear N/A
Completed NCT03688672 - Apioc Contact Lens Feasibility N/A
Completed NCT05741450 - A Clinical Comparison of Two Soft Contact Lenses N/A
Completed NCT01912781 - Safety and Efficacy Evaluation of a New Contact Lens Disinfecting Solution in Gas Permeable Contact Lens Wearers N/A