Clinical Trials Logo

Clinical Trial Summary

In the emergency department and intensive care unit, blood gas analysis is a crucial tool in the assessment of critically ill patients. Blood gas analysis is quick and repeatable at the bedside. The sampling can be done from both arterial and venous samples, with arterial samples generally considered to be more reliable and by that widely used as the standard method. The purpose of this project is to compare venous and arterial blood gas parameters in undifferentiated, critically ill patients. We plan to evaluate the correlation between different parameters through a prospective observational study. In particular, carbon dioxide partial pressure (pCO2) correlation between venous and arterial samples is investigated by using and comparing different conversion models proposed in the literature. 250 patients deemed to be in need of arterial blood gas sampling based on their clinical condition will be included in a consecutive fashion at all hours. The long-term goal is to clinically translate the findings into a limitation on the use of arterial sampling, which could potentially reduce pain and complication risks in the many patients who undergo arterial blood gas sampling every day.


Clinical Trial Description

== Practical procedures & flowchart == Patients included in this study are treated according to clinical routine. After inclusion, sampling of an arterial blood gas and a venous blood gas is performed simultaneously or as close in time as possible. Because the venous blood gas analysis sample can be taken directly from the patient's peripheral venous catheter, no additional venous puncture is usually required and the additional amount of blood that may be required is approx. 1 ml (the assay requires about 500 µl). In the very rare cases where it is not possible to establish a peripheral venous catheter within a reasonable time, the sample will be acquired from a new venous puncture together with other venous routine samples. Sampling can be carried out by doctors or nurses. The arterial and venous blood gas analysis is performed with a blood gas analyzer (ABL90) in the emergency department and is performed immediately after the sampling. Sampling times and analysis times are documented. Survey results are routinely stored in electronic form in patient health record and also locally on the device ABL90 with social security number as ID. The data is saved for statistical analysis. == Documentation == The following parameters are documented during sampling: - Chief complaint - Indication for sampling - The patient's current vital signs at the time of sampling - Ongoing oxygen treatment (flow rate) - Size of cannula, sampling location - Sampling times and analysis times - Number of puncture attempts After sampling, the following is documented: - Analysis results of venous and arterial blood gas sample - Final diagnosis at discharge from the emergency department The documentation will primarily be on worksheets, which will be marked with a patient label (name / social security number) and a serial number. The worksheet will be stored together with consent forms in a locked space of Akutkliniken US Linköping. The data will be archived in the local emergency department or at the Regional Archives in Östergötland according to applicable laws and regulations. The result of blood gas analysis is obtained from the digital lab system in the patient record (Lab-ROS) or directly exported from the internal memory of the analyzers at the emergency department. In both cases, the results will be used for digital compilation of study data. All electronic storage of study data will be pseudonymized by linking to patients serial number. == Statistics == In previous studies, the correlation between arterial and venous samples has been evaluated using several different statistical methods: - T-test, Pearson's and Spearman's R variable - Descriptive data are presented as mean and +/- from SD Our intention in this study is to make a parallel comparison of previously published methods, as well as to examine, based on collected data, whether a new formula with better precision can be derived. == The potential significance of the project == At present, arterial blood gas sampling is used as the standard procedure for assessing a critically ill patient in the emergency department. The project aims to clarify the feasibility of replacing routine arterial blood gas sampling in the emergency department with venous punctures without impairing test results and patient care. If feasible, such a change in sampling routines could potentially mean a great improvement for patients in terms of pain and complication risks. Also, workflow and lead times in the emergency department could be improved by the fact that venous samples may be drawn by all clinical staff, whereas arterial samples are normally reserved for doctors and nurses with dedicated training. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04409470
Study type Observational
Source University Hospital, Linkoeping
Contact
Status Completed
Phase
Start date October 11, 2021
Completion date March 27, 2022

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04688905 - Diagnosing Heart Failure With Preserved Ejection Fraction in Patients With Unexplained Dyspnea (Diagnose-HFpEF)
Completed NCT03679312 - The Effect of Inhaled Nitric Oxide on Dyspnea and Exercise Tolerance in COPD Phase 1/Phase 2
Recruiting NCT04868357 - Hypnosis for the Management of Anxiety and Breathlessness During a Pulmonary Rehabilitation Program N/A
Active, not recruiting NCT03604822 - Music Therapy Protocol to Support Bulbar and Respiratory Functions in ALS N/A
Completed NCT03626519 - Effects of Menthol on Dyspnoea in COPD Patients N/A
Completed NCT02638649 - Prehospital Use of Ultrasound in Undifferentiated Shortness of Breath
Completed NCT02538770 - Rapid Viral Diagnostics in Adults to Reduce Antimicrobial Consumption and Duration of Hospitalization N/A
Terminated NCT02269761 - Chest Ultrasound of ER Patients With Cough or SOB
Completed NCT02248831 - Evaluation of Cardiopulmonary Diseases by Ultrasound N/A
Recruiting NCT01655199 - Sensitivity of the Step Test to Detect Improvement in Dyspnea Following Bronchodilation in Patients With Chronic Obstructive Pulmonary Disease N/A
Active, not recruiting NCT01440764 - Aerosol Inhalation Treatment for Dyspnea Phase 1/Phase 2
Completed NCT01577407 - Non Opioid Treatment for Experimental Dyspnea Phase 3
Completed NCT01193998 - Impact of Validated Diagnostic Prediction Model of Acute Heart Failure in the Emergency Department N/A
Recruiting NCT04327882 - Point-of-care Ultrasound Interest in Dyspneic Emergency Department Patients: an Observational Bicentric Study
Completed NCT05029986 - Preventing Dyspnea During Speech in Older Speakers N/A
Not yet recruiting NCT04181359 - The Effect of Inhaled Nitric Oxide on Dyspnea and Exercise Tolerance in Interstitial Lung Disease. Phase 1/Phase 2
Recruiting NCT04615065 - Acutelines: a Large Data-/Biobank of Acute and Emergency Medicine
Completed NCT04305639 - The Reliability and Validity of Turkish Version of ''The Dyspnea-ALS-Scale (DALS-15)"
Completed NCT04370990 - Automated Oxygen Administration -Rethinking Interventions Alleviating Dyspnea in Patients With COPD N/A
Completed NCT04375917 - Is Reduced Hypoxia Through a Robot Intervention, Associated With Sensory and Emotional Descriptions of Dyspnea, Anxiety, Depression, Symptom Burden and Anxiolytics N/A