Humeral Fracture, Proximal Clinical Trial
Verified date | January 2017 |
Source | Zhoupu Hospital, Pudong New Area, Shanghai, China |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
From April ,2014 to April 2015,31 patients with fractures of the proximal humerus were treated in our hospital. According to anatomic neck fractures (ANF) and surgical neck fractures (SNF), we divided the patients into two groups. All the patients were followed at least 1 year.
Status | Completed |
Enrollment | 31 |
Est. completion date | January 3, 2017 |
Est. primary completion date | December 2016 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 90 Years |
Eligibility |
Inclusion Criteria: -From May ,2013 to April 2015, patients with fractures of the proximal humerus who were treated with locking plate. Exclusion Criteria: - Patients had pathologic fractures, - Patients had previous surgery on the affected shoulder, - Patients were treated with shoulder arthroplasty. - Patients were treated with intramedullary nail. |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Xiaoxiao Zhou |
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | change of head-shaft angle at 12months from 6months in two groups | 12months | ||
Secondary | change of Offset at 12months from 6months in two groups | 12 months | ||
Secondary | Constant-Murly scores at 3 months, 12 months and last follow-up | 3 months,12 months,last follow-up (last follow-up means recent evaluation before database lock, it is more than 12months ) | ||
Secondary | change of the distance between the screw tip and the subchondral surface(TSD) at 12months from 6months in two groups | 12 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03383991 -
Reverse Total Shoulder Arthroplasty Versus Hemiarthroplasty for Displaced 3- and 4-part Proximal Humeral Fractures
|
N/A | |
Not yet recruiting |
NCT03358784 -
Comparison of Hemi-shoulder Arthroplasty and PHILOS in Treating Three or Four-part Fractures of Proximal Humerus
|
N/A | |
Completed |
NCT04821180 -
Psychological Health Influences the Choice of Device in Proximal Humeral Fractures
|
||
Recruiting |
NCT04113044 -
Go Fit Fast, Recovery Trajectory Using PROMIS®, Linking PROMIS®
|