Critical Care Clinical Trial
Official title:
The Performance of Dexcom G6 Glucose Monitoring in Critically Ill Patients
This is an investigator-initiated, prospective, observational accuracy-study. The aim of the study is to test the feasibility, safety, and accuracy of a subcutaneous continuous glucose monitoring system (the Dexcom G6 glucose monitoring system) in critically ill patients. A total of 40 adult patients admitted to the intensive care unit requiring intravenous insulin infusion to maintain blood glucose within target range will be enrolled. Subcutaneous glucose readings will be compared with routine arterial blood glucose measurements to determine accuracy.
The primary endpoint of the study is the mean absolute relative difference (MARD) in percent between CGM and arterial glucose values. Calculations show that 40 patients are required for a 95% confidence interval for the mean to have a range of ±1.7%, meaning that MARD can be estimated with high precision. Calculations of confidence intervals were done using normal approximation, assuming an SD of 5.5 percentage units. The following variables will be collected from the electronic medical record (Take Care), from the ICU-specific patient data management system (Clinisoft) and/or from the handheld Dexcom G6 monitor: Patient-related variables: - Age, sex, height and weight - Comorbidities (including diabetes status) - Chronic medications Clinical variables: - Date and time of ICU admission and discharge - Reason for ICU admission - Admission source (e.g. emergency department, other hospital, ward) - Illness severity scores (e.g. SAPS [Simplified Acute Physiology Score], SOFA [Sequential Organ Failure Assessment]) - Hemodynamic variables (e.g. heart rate, blood pressure) - Blood gas results (including blood glucose concentration) - Other routine laboratory results (e.g. serum creatinine, serum albumin, haematocrit) - ICU mortality Treatment variables: - Insulin doses (including continuous intravenous infusion rates, intravenous and subcutaneous insulin boluses) and times - Doses and administration time for other medications given in the ICU (e.g. Vasopressors, paracetamol) Continuous Glucose Monitoring (CGM)-related variables: - Date and time of sensor insertion - Sensor insertion site - Number and duration of disconnection episodes - Reason for disconnection - Date and time of sensor calibrations - Sensor glucose values with date and time stamps - Date and time of sensor removal - Reason for sensor removal - Complications at sensor insertion site (redness, swelling, infection, bruising) Exact date and time of sensor insertion will be manually recorded in a case report form at the bedside. Every time an arterial blood gas is obtained, the arterial blood glucose value and the corresponding CGM glucose value will be manually recorded along with date and time in the case report form. At the end of the study period, after removing the CGM sensor, CGM-data will be downloaded from the handheld Dexcom G6 monitor. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05114551 -
ICU Predictive Score of WEaning Success in Patients At Risk of Extubation Failure
|
||
Completed |
NCT05547646 -
The Prevalence of Healthcare-associated Infection in Medical Intensive Care Units in Tunisia
|
||
Recruiting |
NCT03697785 -
Weaning Algorithm for Mechanical VEntilation
|
N/A | |
Completed |
NCT02922101 -
Evaluation of the Effectiveness of an Audit and Feedback Intervention With Quality Improvement Toolbox in Intensive Care
|
N/A | |
Completed |
NCT02902783 -
DONATE-Pilot Study on ICU Management of Deceased Organ Donors
|
||
Completed |
NCT01885442 -
TryCYCLE: A Pilot Study of Early In-bed Leg Cycle Ergometry in Mechanically Ventilated Patients
|
N/A | |
Completed |
NCT01857986 -
Evaluating Air Leak Detection in Intubated Patients
|
N/A | |
Recruiting |
NCT05518955 -
VR Integrated Into Multicomponent Interventions for Improving Sleep in ICU
|
N/A | |
Recruiting |
NCT03810768 -
Metabolomics Study on Postoperative Intensive Care Acquired Muscle Weakness
|
||
Completed |
NCT03295630 -
Validity of an Actigraph Accelerometer Following Critical Illness
|
N/A | |
Completed |
NCT05556811 -
HEaling LIght Algorithms for the ICU Patient
|
N/A | |
Recruiting |
NCT05702411 -
Air Stacking Technique For Pulmonary Reexpansion
|
N/A | |
Completed |
NCT02741453 -
Bilateral Internal Jugular Veins Ultrasound Scanning Prior to CVC Placement
|
N/A | |
Recruiting |
NCT04979897 -
Impact on Mental, Physical, And Cognitive Functioning of a Critical Care sTay During the COVID-19 Pandemic
|
||
Completed |
NCT05281224 -
Ventilator Tube Holder for Patients With a Tracheostomy
|
||
Withdrawn |
NCT02970903 -
VitalPAD: an Intelligent Monitoring and Communication Device to Optimize Safety in the PICU
|
N/A | |
Recruiting |
NCT02587273 -
The Pharmacokinetics of Fentanyl in Intensive Care Patients
|
Phase 4 | |
Completed |
NCT02661607 -
Point of Care Echocardiography Versus Chest Radiography for the Assessment of Central Venous Catheter Placement
|
N/A | |
Completed |
NCT01479153 -
Venous Site for Central Catheterization
|
N/A | |
Recruiting |
NCT06110390 -
High-flow Nasal Oxygen Therapy to Prevent Extubation Failure in Adult Trauma Intensive Care Patients
|
N/A |