Clinical Trials Logo

Clinical Trial Summary

Large abdominal wall hernias are surgically challenging to repair and often associated with significant postoperative complications. Risk factors associated with surgical site complications, such as infection and wound dehiscence, include obesity, diabetes, and smoking. In these high risk patients, the placement of synthetic mesh increases the risk of mesh infection, enterocutaneous fistula formation, and mesh explantation. One of the larger studies of risk factors associated with mesh explantation demonstrated concomitant intra-abdominal procedures have a greater than 6-fold increased hazard of subsequent mesh explantation. As an alternative to synthetic meshes, bioprosthetic meshes derived from the decellularization and processing of allogeneic or xenogeneic tissue sources have been introduced that can often allow the surgeon to treat the surgical site occurrences and salvage the repair without required mesh explantation. Low rates of mesh infection and explantation have been reported for bioprosthetic meshes and are recommended in these complicated patients by the Ventral Hernia Working Group, based on the best available clinical evidence. Despite widespread use of bioprosthetic mesh, there continues to be concern for complications associated with their use (i.e. high seroma and recurrence rates, etc.). This has led to the modification of these matrices by several industry leaders (Acelity, Cook, Integra, etc.) to include a fenestrated platform to allow for fluid to flow through the matrix upon implantation while supporting regeneration in complex abdominal wall reconstruction. To our knowledge, there are no clinical studies prospectively evaluating the long term clinical outcomes for abdominal wall reconstruction procedures involving fenestrated macropourous biologic matrices.This macroporous technology allows for tissue revascularization and integration of the biologic graft and thus an expected improvement in overall outcome. Bioprosthetic fenestrated materials such as Surgimend MP® were developed to assist with earlier incorporation and vascularization of the biologic graft while providing reinforcement of hernia repair. However, there is an absence of high quality prospective data regarding the use of these materials in complicated abdominal wall reconstruction, and no comparative data exists. This study is a prospective, case series study evaluating the efficacy and performance of SurgiMend MP® during complex ventral hernia repairs. This case series involves a biologically derived hernia mesh under its cleared FDA indication for hernia repair. Efficacy will be determined by quantifying surgical complications, hernia recurrence, and cost effectiveness endpoints.


Clinical Trial Description

Large abdominal wall hernias are surgically challenging to repair and often associated with significant postoperative complications. Risk factors associated with surgical site complications, such as infection and wound dehiscence, include obesity, diabetes, and smoking. In these high risk patients, the placement of synthetic mesh increases the risk of mesh infection, enterocutaneous fistula formation, and mesh explantation. One of the larger studies of risk factors associated with mesh explantation demonstrated concomitant intra-abdominal procedures have a greater than 6-fold increased hazard of subsequent mesh explantation. As an alternative to synthetic meshes, bioprosthetic meshes derived from the decellularization and processing of allogeneic or xenogeneic tissue sources have been introduced that can often allow the surgeon to treat the surgical site occurrences and salvage the repair without required mesh explantation. Low rates of mesh infection and explantation have been reported for bioprosthetic meshes and are recommended in these complicated patients by the Ventral Hernia Working Group, based on the best available clinical evidence. Despite widespread use of bioprosthetic mesh, there continues to be concern for complications associated with their use (i.e. high seroma and recurrence rates, etc.). This has led to the modification of these matrices by several industry leaders (Acelity, Cook, Integra, etc.) to include a fenestrated platform to allow for fluid to flow through the matrix upon implantation while supporting regeneration in complex abdominal wall reconstruction. To our knowledge, there are no clinical studies prospectively evaluating the long term clinical outcomes for abdominal wall reconstruction procedures involving fenestrated macropourous biologic matrices.This macroporous technology allows for tissue revascularization and integration of the biologic graft and thus an expected improvement in overall outcome. Bioprosthetic fenestrated materials such as Surgimend MP® were developed to assist with earlier incorporation and vascularization of the biologic graft while providing reinforcement of hernia repair. However, there is an absence of high quality prospective data regarding the use of these materials in complicated abdominal wall reconstruction, and no comparative data exists. This study is a prospective, case series study evaluating the efficacy and performance of SurgiMend MP® during complex ventral hernia repairs. This case series involves a biologically derived hernia mesh under its cleared FDA indication for hernia repair. Efficacy will be determined by quantifying surgical complications, hernia recurrence, and cost effectiveness endpoints. Subjects will be identified by the investigators and/or personnel assigned by the investigators, as patients with large complex ventral hernia expected to be repaired with bioprosthetic mesh. Subjects will have a baseline visit where they will have a physical exam and complete quality of life questionnaires and a pain scale. Photographs will be taken at this visit as well. Demographic and medical and surgical history will be collected. The investigators will then assess the subject intra-operatively to confirm the need and appropriate placement of SurgiMend mesh. The subjects that have mesh placed will be followed at hospital discharge, 3 months, 6 months, and 12 months to assess for changes in health, adverse events, questionnaire completion, and evaluation of surgical site for complications and recurrence. The visits may take place by phone if the subject cannot return to clinic. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03450473
Study type Interventional
Source Washington University School of Medicine
Contact
Status Completed
Phase N/A
Start date January 3, 2018
Completion date December 31, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT06051578 - Abdominal Wall Tension in Patients Undergoing Ventral Hernia Repair Without Component Separation
Recruiting NCT04098380 - Small Versus Large Bite Closure of Emergency Midline Laparotomy N/A
Completed NCT02616718 - Incisional Hernia Progression Over Time N/A
Completed NCT06034652 - T-GENVIH-003 LTFU (Long Term Follow Up) Study
Completed NCT04222517 - The Use of Local Hemostatic in Patients With Large Incisional Hernias N/A
Completed NCT00749268 - AbsorbaTack Evaluation of Postoperative Pain Following Laparoscopic Hernia Repair Phase 4
Not yet recruiting NCT05467124 - Enhanced Recovery After Abdominal Wall Reconstruction
Completed NCT00472537 - ProLOVE - Prospective Randomized Study of Midline Incisional Hernia Treatment N/A
Active, not recruiting NCT02365194 - Modifying Risk in Ventral Hernia Patients N/A
Recruiting NCT04718168 - GORE® ENFORM Biomaterial Product Study N/A
Completed NCT02594241 - PreOperative Steroid in Abdominal Wall Reconstruction: A Double-blinded Randomized Clinical Trial N/A
Active, not recruiting NCT02363790 - Primary Fascial Closure With Laparoscopic Ventral Hernia Repair: A Randomized Controlled Trial N/A
Completed NCT02398565 - Pregnancy Subsequent to Ventral Hernia Repair N/A
Terminated NCT02041494 - Complex Ventral Hernia Repair Using Biologic or Synthetic Mesh N/A
Completed NCT00532870 - Laparoscopic Intraperitoneal Mesh Repair of Ventral Hernia: Comparison to Conventional Mesh Repair N/A
Completed NCT05320055 - Pain and Readmission After Lap IPOM vs. Robotic Ventral Hernia Repair
Completed NCT04229940 - Peritoneal in Laparoscopic Ventral Hernia Repair 2 Phase 2
Completed NCT05446675 - Endoscopic eTEP Versus Open Rives-Stoppa
Completed NCT05912868 - Endoscopic Mini/Less Open Sublay(EMILOS) Repair
Withdrawn NCT04143776 - Renal- and Pulmonary Function in Relation to Abdominal Hypertension After Abdominal Reconstruction