Clinical Trial Summary

This study is Phase 3 of a three-phase DOD CDMRP funded project for the development of a multi-technology poly-anatomic noninvasive system for early detection of occult hemorrhage. Early detection of ongoing hemorrhage (OH) before onset of shock is a universally acknowledged great unmet need, and particularly important after trauma. Delays in the detection of OH are associated with a "failure to rescue" and a dramatic deterioration in prognosis once the onset of clinically frank shock has occurred. An early alert to the presence of OH with an acceptable rate of false-positives and false-negatives would save countless lives. Additionally, such technology would save significant time, money and effort by allowing medical resources to be applied more accurately - the essence of precision medicine. An automated system would monitor currently stable patients continuously, leaving clinicians free to care for patients in need of attention.


Description:

The investigators will enroll 480 trauma patients in a "no significant risk" prospective clinical trial to 1) evaluate the performance of a Mark I prototype, 2) validate the performance of the Phase II algorithm, and 3) re-train the algorithm to Phase III iteration. This is not a therapeutic study. The main outcome variables are non-invasive measurements that will be used for machine learning, not real-time patient management. The data generated will be used later for discovery and validation in traditional and innovative machine learning. As a minimal risk study, there will be no change from standard of care for patients undergoing surgery. The surgical procedures and pharmacotherapies will proceed as per standard clinical management. Enrolled patients will undergo standard preoperative, anesthetic, and postoperative physiological monitoring that includes: Electrocardiogram: Heart rate and electrical activity of the heart will be recorded via a 3-lead ECG. Arterial Oxygen Saturation (SpO2): Pulse oximetry will be recorded using a commercially available finger pulse oximeter. Finger Photoplethysmography: waveforms will be obtained non-invasively from either the SpO2 photoplethysmography or alternatively a Flashback Technologies Compensatory Reserve Index (CRI™) device. In addition to these standard physiologic measurements, as a part of the research, the investigators will also acquire the following non-invasive optical and impedance measurements. All of these devices have been previously validated as non-invasive and safe in humans. The impedance electrodes and optical emitter/detectors will be incorporated into easily applied latex-free based "belts" that will be applied to anatomic locations along the thorax, abdomen and thigh. Application of these belts will be as soon as practical after patient arrival. The clinicians providing care to the patient will be blind with respect to the measurements from these devices. Continuous-wave Near-Infrared Spectroscopy (CW-NIRS) Device, custom built: The device is built on an Ocean Optics FLAME USB Spectrometers, with two OSRAM 4736 NIR LEDs in plastic holders meant to be taped or strapped to the patient on the chest/torso and thigh locations. An Oceans Optics tungsten-halogen light source is used for an additional probe location on the forehead. Probe holders are designed to collect light from surface of skin by means of a mirror and collimator. The device will collect data on light attenuation of muscle in models of shock/trauma. The light output for all locations is below the ANSI limits for maximum permissible skin exposure. SwissTom Electrical Impedance Tomography (EIT) System: Name of device: Pioneer Set (Electrical Impedance Tomography System) Device Manufacturer: SwissTom AG (Parent company SenTec AG) This device monitors dynamically changing perfusion physiology. To record multiplexed impedance signature a belt of 16-32 electrodes is placed around the thorax above the nipple line and thigh and impedances are recorded between multiple sets of electrodes. SwissTom develops a clinical EIT system that is approved for pulmonary imaging. This Pioneer system is their research platform that has similar functionality and safety performance to their clinical system but provides research teams with access to raw data and additional functionality for specifying imaging parameters (e.g. control of frame rates, signal frequency acquisition, electrode drive patterns). ScioSpec MultiChannel Electrical Impedance Spectroscopy (EIS) System: Name of device: ISX-Mini (MultiChannel Electrical Impedance Spectroscopy System) Device Manufacturer: ScioSpec To record multiplexed impedance signatures- an array of 4 electrodes is placed around the cranium and thorax of the patient and impedance spectroscopy signatures are recorded at each anatomic location. This device monitors dynamically changing intracranial, intrathoracic and intra-abdominal physiology. General Approach to Minimize Risk: This protocol will be minimal risk to patients as there is little risk associated with the placement of these devices and they can be removed at any time. They don't interfere with standard equipment used in clinical management of trauma patients.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 480
Est. completion date September 2022
Est. primary completion date September 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. Awake and alert GCS >14 2. Admission systolic blood pressure greater than 90 and heart rate less than 120 3. Without signs of clinically significant ongoing external hemorrhage with no active bleeding documented on radiology/ultrasound and stable vital signs (no signs of hemodynamic deterioration) during initial evaluation (approximately 15 minutes post admission) Exclusion Criteria: 1. Altered mental status GCS < 13 2. Systolic blood pressure less than 90 or heart rate greater than 120 3. Need for ongoing fluid or pressor support (standard local fluid resuscitation only) 4. Clinically significant ongoing external hemorrhage 5. Respiratory distress with O2 saturation <96% 6. Pre-existing systemic illness, likely to alter systemic cardiovascular response to hemorrhage (overt clinical heart failure). Including congestive heart failure, and a paced cardiac rhythm. 7. Pregnant 8. Prisoner status

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Detection of Occult Hemorrhage in Trauma Patients
Non-invasive monitoring of trauma patients

Locations

Country Name City State
United States R Adams Cowley Shock Trauma Center Baltimore Maryland

Sponsors (4)

Lead Sponsor Collaborator
Norman A. Paradis Dartmouth College, United States Department of Defense, University of Maryland Shock Trauma Center

Country where clinical trial is conducted

United States, 

References & Publications (8)

Belle A, Ansari S, Spadafore M, Convertino VA, Ward KR, Derksen H, Najarian K. A Signal Processing Approach for Detection of Hemodynamic Instability before Decompensation. PLoS One. 2016 Feb 12;11(2):e0148544. doi: 10.1371/journal.pone.0148544. eCollection 2016. — View Citation

Convertino VA, Moulton SL, Grudic GZ, Rickards CA, Hinojosa-Laborde C, Gerhardt RT, Blackbourne LH, Ryan KL. Use of advanced machine-learning techniques for noninvasive monitoring of hemorrhage. J Trauma. 2011 Jul;71(1 Suppl):S25-32. doi: 10.1097/TA.0b013e3182211601. Review. — View Citation

Convertino VA. Blood pressure measurement for accurate assessment of patient status in emergency medical settings. Aviat Space Environ Med. 2012 Jun;83(6):614-9. — View Citation

Kim SH, Lilot M, Sidhu KS, Rinehart J, Yu Z, Canales C, Cannesson M. Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis. Anesthesiology. 2014 May;120(5):1080-97. doi: 10.1097/ALN.0000000000000226. Review. — View Citation

Parks JK, Elliott AC, Gentilello LM, Shafi S. Systemic hypotension is a late marker of shock after trauma: a validation study of Advanced Trauma Life Support principles in a large national sample. Am J Surg. 2006 Dec;192(6):727-31. — View Citation

Shackelford SA, Colton K, Stansbury LG, Galvagno SM Jr, Anazodo AN, DuBose JJ, Hess JR, Mackenzie CF. Early identification of uncontrolled hemorrhage after trauma: current status and future direction. J Trauma Acute Care Surg. 2014 Sep;77(3 Suppl 2):S222-7. doi: 10.1097/TA.0000000000000198. Review. — View Citation

Soller BR, Yang Y, Soyemi OO, Ryan KL, Rickards CA, Walz JM, Heard SO, Convertino VA. Noninvasively determined muscle oxygen saturation is an early indicator of central hypovolemia in humans. J Appl Physiol (1985). 2008 Feb;104(2):475-81. Epub 2007 Nov 15. — View Citation

Wo CC, Shoemaker WC, Appel PL, Bishop MH, Kram HB, Hardin E. Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness. Crit Care Med. 1993 Feb;21(2):218-23. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Algorithm performance: time of alarm before onset of deterioration patient data will be collected over 3-6 hours
Primary Algorithm performance: Sensitivity as measured by for alarm/no alarm outcome patient data will be collected over 3-6 hours
Primary Algorithm performance: Specificity as measured by for alarm/no alarm outcome patient data will be collected over 3-6 hours
Primary Algorithm performance: Positive predictive value for alarm/no alarm outcome patient data will be collected over 3-6 hours
Primary Algorithm performance: Negative predictive value for alarm/no alarm outcome patient data will be collected over 3-6 hours
See also
  Status Clinical Trial Phase
Completed NCT02815670 - Reversal Dabigatran Anticoagulant Effect With Idarucizumab Phase 3
Completed NCT04588350 - Clinical Investigation Evaluating a New Autotransfusion Device in Cardiac Surgery N/A
Recruiting NCT02972385 - Pharmacogenomics of Warfarin in Hispanics and Latinos
Completed NCT02569606 - Transfusion and Coagulation Management in Trauma Patients After the Introduction of a Coagulation Algorithm
Completed NCT02554006 - Predischarge Bundle to Minimize Negative Impact on Quality of Life of Nuisance Bleedings N/A
Recruiting NCT02446730 - Efficacy and Safety of BiomatrixTM Stent and 5mg-Maintenance Dose of Prasugrel in Patients With Acute Coronary Syndrome Phase 4
Completed NCT01955720 - Safety, Tolerability, PK and PD of BI 655075 and Establishment of BI 655075 Dose(s) Effective to Reverse Prolongation of Blood Coagulation Time by Dabigatran Phase 1
Completed NCT01935427 - Comparison of Compensatory Reserve Index to Intravascular Volume Change and Stroke Volume N/A
Recruiting NCT01709786 - Non-Invasive Hemoglobin Monitoring in Patients With Hemorrhage N/A
Completed NCT01191554 - Dose-ranging Study of Tranexamic Acid in Valve Surgery N/A
Completed NCT01210417 - Trauma Heart to Arm Time N/A
Completed NCT01136590 - Multicenter, Randomized Placebo-controlled Clinical Trial to Evaluate the Effect of Perioperative Use of Tranexamic Acid on Transfusion Requirements and Surgical Bleeding in Major Spine Surgery Phase 4
Completed NCT01085006 - The Effect of Tranexamic Acid on Postpartum Hemorrhage During and After Cesarean Delivery Phase 1/Phase 2
Completed NCT00700141 - Non-Interventional Study About Treatment of Hemorrhages in Thyroid Surgery With TachoSil® N/A
Completed NCT00375466 - Tranexamic Acid, Hemorrhage and Transfusions After Combined Aortic Valve Replacement and Coronary Artery Bypass Surgery. N/A
Completed NCT00479362 - Anticoagulant Therapy During Pacemaker Implantation Phase 4
Completed NCT00147420 - RCT of Zhi Byed 11 (ZB11) Versus Misoprostol in Tibet N/A
Recruiting NCT05945680 - Tranexamic Acid in Breast Esthetic Surgery. Phase 4
Completed NCT03273322 - Assessment of Dual Antiplatelet Therapy Versus Rivaroxaban In Atrial Fibrillation Patients Treated With Left Atrial Appendage Closure Phase 2/Phase 3
Withdrawn NCT05672407 - The Role of Local Tranexamic Acid on Periorbital Oculoplastic Surgery Phase 4