Clinical Trials Logo

Clinical Trial Summary

Early detection of ongoing hemorrhage (OH) before onset of hemorrhagic shock is a universally acknowledged great unmet need, and particularly important after traumatic injury. Delays in the detection of OH are associated with a "failure to rescue" and a dramatic deterioration in prognosis once the onset of clinically frank shock has occurred. An early alert to the presence of OH would save countless lives. This is a single site study, enrolling 48 patients undergoing liver resection in a "no significant risk" prospective clinical trial to: 1) further identify a minimal subset of noninvasive measurement technologies necessary for the desired diagnostic performance, 2) validate the performance of our Phase I algorithm, and 3) re-train the algorithm to a Phase II human iteration. The main outcome variables are non-invasive measurements that will be used for machine learning, not real-time patient management. The data generated will be used later for discovery and validation in traditional and innovative machine learning.


Clinical Trial Description

Hemorrhagic shock remains a leading cause of death on the battlefield as well in civilian communities. Early detection of ongoing hemorrhage before progression to frank shock would allow early intervention. It is widely appreciated that the classic medical vital signs perform poorly until late in the progression to shock after traumatic injury. Currently available techniques, including intermittent vital sign monitoring, laboratory analysis, and single measurement devices have poor performance before clinically obvious physiologic distress. The overall goal of this project is to develop a multi-technology noninvasive system for early detection of ongoing hemorrhage. The underlying hypothesis is that deep learning developed algorithms obtaining diagnostic signals from multiple sources will outperform single technology solutions. While the promise of innovative noninvasive testing has received wide attention, development of effective bedside technologies has thus far been limited and their performance disappointing. In 2014, Kim et al stated that "The results from this meta-analysis found that inaccuracy and imprecision of continuous noninvasive arterial pressure monitoring devices are larger than what was defined as acceptable" and noninvasive blood pressure measurement is among the most fully developed of these technologies. The failure of noninvasive technologies in the detection or diagnosis of complex disease states has been essentially complete. The investigators believe that this failure reflects the limitations of uniplex systems (a single sensor in a single-location) and patient-to-patient variation in physiologic response. Uniplex systems sacrifice the entire diagnostic signal in anatomic-temporal patterns, which likely has significant discriminant power. To date, technological innovation in early detection of ongoing hemorrhage has been of two broad categories: 1) a search to discover a single new measurement of tissue or organ status or 2) application of more sophisticated mathematical techniques based on machine learning and signal processing. The investigators propose to develop a system that combines state-of-the-art noninvasive sensing technologies and advanced multivariable statistical algorithms. This system will be developed from its inception to be inexpensive and easily applied, even in austere settings. To avoid the unnecessary use of blood products, hepatectomies are performed with low central venous pressure (CVP). This is accomplished through restrictive use of intravenous fluids and at times medications to lower the central venous pressure. Low central venous pressure during hepatectomy is an excellent model for development of technologies such as ours and has not been previously used for this purpose. During each procedure, the investigators will obtain a full ensemble of noninvasive optical, electromagnetic and impedance physiological signals during the LCVPLR procedure. The work proposed herein will evaluate these technologies during standard low central venous pressure liver resections (LCVPLR). These data will be utilized for further machine learning-based algorithm development. The proposed study will be low risk since the measured data will not be available to the clinicians. Specific Aims: 1. Evaluate the performance of existing non-invasive sensing technologies and multivariable algorithms in LCVPLR. 2. Obtain human model training and validation data sets during LCVPLR for further refinement of the algorithms. Power and Sample Size: The investigators anticipate acquiring data from every enrolled subject. The data obtained before onset of parenchymal transection will be utilized as the "no hemorrhage" control. Power and sample size calculations indicate that a sample size of 48 subjects should be sufficient to: 1) further identify the minimal subset of noninvasive measurement technologies necessary for the desired diagnostic performance, 2) validate the existing algorithms, and 3) initially train a human clinical iteration of the algorithms, with a sufficient degree of accuracy (p < 0.05 for ROC-AUC). As a minimal risk study, there will be no change from standard of care for patients undergoing surgery. The surgical procedures and pharmacotherapies will proceed as per standard clinical management. Enrolled patients will undergo standard preoperative, anesthetic, and postoperative physiological monitoring. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04814810
Study type Observational
Source Dartmouth-Hitchcock Medical Center
Contact
Status Terminated
Phase
Start date February 1, 2021
Completion date April 15, 2021

See also
  Status Clinical Trial Phase
Completed NCT02815670 - Reversal Dabigatran Anticoagulant Effect With Idarucizumab Phase 3
Completed NCT04588350 - Clinical Investigation Evaluating a New Autotransfusion Device in Cardiac Surgery N/A
Recruiting NCT02972385 - Pharmacogenomics of Warfarin in Hispanics and Latinos
Completed NCT02554006 - Predischarge Bundle to Minimize Negative Impact on Quality of Life of Nuisance Bleedings N/A
Completed NCT02569606 - Transfusion and Coagulation Management in Trauma Patients After the Introduction of a Coagulation Algorithm
Recruiting NCT02446730 - Efficacy and Safety of BiomatrixTM Stent and 5mg-Maintenance Dose of Prasugrel in Patients With Acute Coronary Syndrome Phase 4
Completed NCT01955720 - Safety, Tolerability, PK and PD of BI 655075 and Establishment of BI 655075 Dose(s) Effective to Reverse Prolongation of Blood Coagulation Time by Dabigatran Phase 1
Completed NCT01935427 - Comparison of Compensatory Reserve Index to Intravascular Volume Change and Stroke Volume N/A
Recruiting NCT01709786 - Non-Invasive Hemoglobin Monitoring in Patients With Hemorrhage N/A
Completed NCT01136590 - Multicenter, Randomized Placebo-controlled Clinical Trial to Evaluate the Effect of Perioperative Use of Tranexamic Acid on Transfusion Requirements and Surgical Bleeding in Major Spine Surgery Phase 4
Completed NCT01210417 - Trauma Heart to Arm Time N/A
Completed NCT01191554 - Dose-ranging Study of Tranexamic Acid in Valve Surgery N/A
Completed NCT01085006 - The Effect of Tranexamic Acid on Postpartum Hemorrhage During and After Cesarean Delivery Phase 1/Phase 2
Completed NCT00700141 - Non-Interventional Study About Treatment of Hemorrhages in Thyroid Surgery With TachoSil® N/A
Completed NCT00375466 - Tranexamic Acid, Hemorrhage and Transfusions After Combined Aortic Valve Replacement and Coronary Artery Bypass Surgery. N/A
Completed NCT00479362 - Anticoagulant Therapy During Pacemaker Implantation Phase 4
Completed NCT00147420 - RCT of Zhi Byed 11 (ZB11) Versus Misoprostol in Tibet N/A
Recruiting NCT05945680 - Tranexamic Acid in Breast Esthetic Surgery. Phase 4
Completed NCT03273322 - Assessment of Dual Antiplatelet Therapy Versus Rivaroxaban In Atrial Fibrillation Patients Treated With Left Atrial Appendage Closure Phase 2/Phase 3
Withdrawn NCT05672407 - The Role of Local Tranexamic Acid on Periorbital Oculoplastic Surgery Phase 4