Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT05236426
Other study ID # UWMOlsztyn
Secondary ID
Status Not yet recruiting
Phase
First received
Last updated
Start date February 2022
Est. completion date December 2023

Study information

Verified date February 2022
Source University of Warmia and Mazury in Olsztyn
Contact Jan Adamski, MD,PhD
Phone +48600700315
Email janski01@hotmail.com
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The aim of the study is to determine the correlation of the results of cardiac index (CI) measurements performed with use of bioreactance technology with the results of measurements made with the use of transpulmonary thermodilution. Both methods will be evaluated in reference to measurements based on echocardiography.


Description:

After approval of the study design by the institutional ethics committee, 50 critically ill adult patients (requiring haemodynamic monitoring and mechanical ventilation) treated in the ICU for a intracranial pathology will be enrolled in the study. Exclusions: Age under 18, presence of pleural effusion or pericardium (confirmed by chest X-ray and / or ultrasound / echocardiography), presence of aortic / mitral valve disease, presence of an implanted pacemaker CI measurements will be performed simultaneously for 5 minutes. The CI value measured by the transpulmonary thermodilution technique will be obtained with the PiCCO system (Pulsiocat PV8115; Pulsion Medical Systems, Feldkirchen, Germany). Measurements will be made three times within 5 minutes. For statistical purposes, the value of the arithmetic mean of the obtained results will be used. The CI value as measured by the bioreactance method will be determined using the monitor: Starling Fluid Management System (Baxter International Inc, USA). This monitor uses bioreactance technology to determine hemodynamic parameters and bioimpedance technology to measure thoracic fluid content (TFC). The test data will be recorded with two pairs of electrodes placed on the chest according to the manufacturer's instructions. Measurements documented at 30-second intervals will concern 10 measurement cycles. The average of the obtained results will be subjected to statistical analysis. Echocardiographic examination of the heart to determine the value of CI will be performed by one (always the same) qualified (certified in echocardiographic examinations) clinician. Echocardiographic measurements will begin with determining the diameter of the left ventricular outflow tract (left ventricular outflow tract cross-sectional area, LVOT-CSA). Then, three subvalvular velocity time integral (LVOT-VTI) measurements will be made over the course of 5 minutes. This measurement will be performed in the apical five-chamber projection. The stroke volume (SV) value will be calculated as: SV = LVOT-CSA x LVOT-VTI. The CI value will be calculated using the formula: CI = SV x heart rate (HR) / body surface area (BSA). The CI value archived for further statistical analysis will be the average of three measurements performed within 5 minutes. Other variables that will be documented simultaneously with CI measurements: patient gender and weight, use of vasospastic / inotropic drugs (dose mcg / kg / min), positive end expiratory pressure (PEEP), presence of pulmonary hypertension.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 50
Est. completion date December 2023
Est. primary completion date December 2023
Accepts healthy volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - 50 critically ill adult patients (requiring haemodynamic monitoring and mechanical ventilation) treated in the ICU for a intracranial pathology Exclusion Criteria: - Age under 18 - Presence of pleural effusion or pericardium (confirmed by chest X-ray and / or ultrasound / echocardiography) - Presence of aortic / mitral valve pathology - Presence of an implanted pacemaker

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
University of Warmia and Mazury in Olsztyn

References & Publications (10)

Demiselle J, Mercat A, Asfar P. Is there still a place for the Swan-Ganz catheter? Yes. Intensive Care Med. 2018 Jun;44(6):954-956. doi: 10.1007/s00134-018-5158-0. Epub 2018 May 23. — View Citation

Geerts BF, Aarts LP, Jansen JR. Methods in pharmacology: measurement of cardiac output. Br J Clin Pharmacol. 2011 Mar;71(3):316-30. doi: 10.1111/j.1365-2125.2010.03798.x. Review. — View Citation

Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol. 2007 Jul;293(1):H583-9. Epub 2007 Mar 23. — View Citation

Kobe J, Mishra N, Arya VK, Al-Moustadi W, Nates W, Kumar B. Cardiac output monitoring: Technology and choice. Ann Card Anaesth. 2019 Jan-Mar;22(1):6-17. doi: 10.4103/aca.ACA_41_18. Review. — View Citation

Lamia B, Kim HK, Severyn DA, Pinsky MR. Cross-comparisons of trending accuracies of continuous cardiac-output measurements: pulse contour analysis, bioreactance, and pulmonary-artery catheter. J Clin Monit Comput. 2018 Feb;32(1):33-43. doi: 10.1007/s10877-017-9983-4. Epub 2017 Feb 10. — View Citation

Ling HZ, Gallardo-Arozena M, Company-Calabuig AM, Nicolaides KH, Kametas NA. Clinical validation of bioreactance for the measurement of cardiac output in pregnancy. Anaesthesia. 2020 Oct;75(10):1307-1313. doi: 10.1111/anae.15110. Epub 2020 May 29. — View Citation

Malik SB, Chen N, Parker RA 3rd, Hsu JY. Transthoracic Echocardiography: Pitfalls and Limitations as Delineated at Cardiac CT and MR Imaging. Radiographics. 2017 Mar-Apr;37(2):383-406. doi: 10.1148/rg.2017160105. Epub 2017 Feb 17. Review. Erratum in: Radiographics. 2017 May-Jun;37(3):1004. — View Citation

Porter TR, Shillcutt SK, Adams MS, Desjardins G, Glas KE, Olson JJ, Troughton RW. Guidelines for the use of echocardiography as a monitor for therapeutic intervention in adults: a report from the American Society of Echocardiography. J Am Soc Echocardiogr. 2015 Jan;28(1):40-56. doi: 10.1016/j.echo.2014.09.009. — View Citation

Raval NY, Squara P, Cleman M, Yalamanchili K, Winklmaier M, Burkhoff D. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique. J Clin Monit Comput. 2008 Apr;22(2):113-9. doi: 10.1007/s10877-008-9112-5. Epub 2008 Mar 14. — View Citation

Squara P, Denjean D, Estagnasie P, Brusset A, Dib JC, Dubois C. Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med. 2007 Jul;33(7):1191-1194. doi: 10.1007/s00134-007-0640-0. Epub 2007 Apr 26. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Cardiac Index value measured by the transpulmonary thermodilution technique The cardiac index is expressed with units : Liters/minute/meter2 The results of three measurements will be documented within five minutes
Primary Cardiac Index value measured with use of bioreactance technology The cardiac index is expressed with units : Liters/minute/meter2 The results of ten measurements at intervals of 30 seconds will be documented within five minutes
Primary Cardiac index value determined with use an ultrasound technique (echocardiography) The cardiac index is expressed with units : Liters/minute/meter2 The results of three measurements will be documented within five minutes
See also
  Status Clinical Trial Phase
Completed NCT03653910 - Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope N/A
Completed NCT06000098 - Consol Time and Acute Kidney Injury in Robotic-assisted Prostatectomy
Recruiting NCT02565251 - Volemic Resuscitation in Sepsis and Septic Shock N/A
Terminated NCT02365688 - Hemodynamic Response During Goal Directed Fluid Therapy in the OR N/A
Completed NCT01559675 - Trial Comparing Low Dose and High Dose Steroids in Patients Undergoing Colorectal Surgery N/A
Completed NCT01605279 - Dobutamine Versus Placebo for Low Superior Vena Cava Flow in Newborns Phase 2
Recruiting NCT04010058 - Postoperative Continuous Non-invasive Haemodynamic Monitoring on the Ward N/A
Completed NCT06268275 - Comparison of Effects of Scalp Block and Intravenous Esmolol on Hemodynamic Response Following the Skull Pins Application for Elective Supratentorial Craniotomy N/A
Recruiting NCT04926220 - Dynamic Estimation of Cardiac Output in the Operating Room
Not yet recruiting NCT05003011 - Correlation of Hemodynamics Via Pulmonary Artery Catherization and the Cardiospire
Completed NCT03599440 - Effect of Extended Infusion Lines on Pulse Contour-based Measurements
Completed NCT05035485 - Maternal Cardiac Output Response to Rescue Norepinephrine and Phenylephrine Boluses in Patients With Severe Preeclampsia N/A
Not yet recruiting NCT04227821 - Hemodynamic Optimalization in Pediatric Patients
Completed NCT05481047 - Prevention or Treatment of Arterial Hypotension and Oxygen Cerebral Saturation During Major Abdominal Surgery N/A
Completed NCT06158165 - Evaluating The Cardiovascular Effects of Tourniquet Application
Not yet recruiting NCT04076709 - Cardiovascular Effects of Muscle Relaxation During Laparoscopic Surgery Phase 4
Completed NCT04089098 - VOLume and Vasopressor Therapy in Patients With Hemodynamic instAbility
Not yet recruiting NCT03828032 - Multi-parameters'Change Process During Dehydration Therapy on Brain Edema Patients. N/A
Recruiting NCT05570682 - Manually Controlled Infusion vs Target Controlled Infusion for StrokeThrombectomy N/A
Completed NCT04574908 - A Pilot Trial of Continuous Portable Postoperative Hemodynamic And Saturation Monitoring On Hospital Wards N/A